Abstract
With the advancement of the Industrial Internet of Things (IIoT), wireless medical sensor networks (WMSNs) have become integral to modern healthcare, enabling the collection of real-time patient data—a field known as HealthIIoT. Due to the limited resources of wearable devices, this data is typically outsourced to cloud servers. However, ensuring data integrity is critical for accurate diagnosis. This paper proposes PAMSD, an efficient public auditing scheme designed for HealthIIoT. By utilizing a novel online/offline tag generation algorithm and a secure hash function for data blinding, PAMSD addresses the dual challenges of real-time processing and patient privacy. Experimental results demonstrate that PAMSD significantly improves tag generation efficiency and auditing performance compared to existing state-of-the-art schemes.
Introduction
In the era of digital health, wearable sensors continuously monitor vital signs such as heart rate and ECG. These lightweight devices lack the storage and computational power to manage the vast amounts of data they generate, necessitating the use of cloud-assisted storage. However, outsourcing introduces security risks, primarily concerning data integrity. If medical data is corrupted or altered in the cloud, it could lead to life-threatening misdiagnoses.
Two primary obstacles hinder effective auditing in this context:
- The Real-Time Bottleneck: Traditional auditing requires sensors to perform complex mathematical operations to generate security "tags" for every data packet. This process is too energy-intensive for battery-powered wearables.
- The Privacy Paradox: While a Third-Party Auditor (TPA) is needed to verify the cloud's integrity, medical data is highly sensitive. The TPA must be able to verify the data's existence and correctness without ever accessing the actual medical values.
System Architecture
The proposed system involves four main entities: the patient (equipped with sensors), the Cloud Service Provider (CSP), the Third-Party Auditor (TPA), and the medical professional (doctor).
As shown in the architecture, medical data flows from the patient's mobile terminal to the cloud. The TPA manages the integrity verification by issuing challenges to the CSP, which responds with proofs. The doctor can then access the verified data for clinical decision-making.
The PAMSD Scheme
The core of the PAMSD (Public Auditing for Medical Sensor Data) scheme is built upon the Zhang–Safavi–Susilo (ZSS) short signature and bilinear pairings. To optimize performance, the scheme introduces a two-phase tag generation process.
Online/Offline Tag Generation
The "heavy lifting" of cryptographic computation is shifted to an Offline Phase. During periods of sensor inactivity, the device pre-calculates random numbers ($w_i$) and auxiliary parameters ($r_i$). When real-time medical data ($m_i$) is captured, the Online Phase requires only a single, lightweight modular arithmetic operation to finalize the tag ($\sigma_i$). This approach ensures that the real-time burden on the sensor is negligible, preserving battery life and reducing latency.
Privacy-Preserving Auditing
To resolve the privacy paradox, PAMSD employs a secure hash function to "blind" the data proof ($\Omega$). Because hash functions are preimage resistant, the TPA can mathematically verify the integrity of the data blocks without being able to reverse-engineer the sensitive medical information. This ensures the TPA remains "credible but curious"—capable of verification but barred from data access.
Performance Evaluation
The researchers evaluated PAMSD against two prominent schemes: CLPA and OOPDP. Testing was conducted using simulated data blocks (4 KB each) ranging from 5,000 to 50,000 units.
- Efficiency: In the critical online phase, PAMSD's tag generation was significantly faster than CLPA, which lacks an offline/online split.
- Verification Speed: The TPA's verification time for a standard challenge (e.g., 460 blocks) was approximately 15ms for PAMSD, a dramatic improvement over the 1600ms required by CLPA.
- Communication Overhead: The proof size remains minimal ($|G_1| + |Z_p^*|$), ensuring that auditing processes do not congest the network.
Conclusion
PAMSD provides a robust solution for the unique constraints of HealthIIoT. By decoupling the computational burden of security tagging and implementing privacy-blinding techniques, the scheme allows for real-time, secure, and private medical data auditing. Future work may explore extending this efficiency to dynamic data operations, such as frequent record updates or deletions, and further reducing the dependency on mobile gateways.
Summary updated