NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Proton radiation effect of NPN-input operational amplifier under different bias conditions

Ke Jiang, Wu Lu, Qi Guo, Chengfa He, Xin Wang, Mohan Liu, Xiaolong LiJournal of Semiconductors 2015

Abstract

NPN-input bipolar operational amplifiers LM741 were irradiated with 60Co γ-ray, 3 MeV protons and 10 MeV protons respectively at different biases to investigating the proton radiation response of the NPN-input operational amplifier. The comparison of protons with 60Co γ-rays showed that the proton radiation mainly induced ionization damage in LM741. Under different bias conditions, the radiation sensitivity is different; zero biased devices show more radiation sensitivity in the input biased current than forward biased devices. Supply current (±Icc) is another parameter that is sensitive to proton radiation, 60Co γ-ray, 3 MeV and 10 MeV proton irradiation would induce a different irradiation response in ±Icc, which is caused by different ionization energy deposition and displacement energy deposition of 60Co γ-ray, 3 MeV and 10 MeV proton irradiation.
BibTeX
@article{jiang2015proton,
  author = {Ke Jiang and Wu Lu and Qi Guo and Chengfa He and Xin Wang and Mohan Liu and Xiaolong Li},
  title = {{Proton radiation effect of NPN-input operational amplifier under different bias conditions}},
  journal = {Journal of Semiconductors},
  year = {2015},
  doi = {10.1088/1674-4926/36/12/125001},
}

Loading related content...

Figure