Projection image-to-image translation in hybrid X-ray/MR imaging

Bernhard Stimpel, Christopher Syben, Tobias Würfl, Katharina Breininger, Katrin Mentl, Jonathan M. Lommen, Arnd Dörfler, Andreas MaierarXiv 2018 · DOI

TL;DR

This paper introduces a deep learning approach to translate MR projection images into corresponding X-ray projection images, enabling better image fusion and enhancement in hybrid interventional suites. By redistributing network capacity to higher-resolution layers and incorporating a Sobel-based edge-weighted loss function, the method successfully captures the sharp, high-frequency bone structures that are typically missing or poorly defined in MRI.

What Problem Does This Paper Address?

In image-guided interventional procedures, combining the real-time, dense-tissue tracking of X-ray fluoroscopy with the rich soft-tissue contrast of Magnetic Resonance Imaging (MRI) is highly desirable. However, to leverage advanced post-processing techniques like image fusion, de-noising, or super-resolution, the data from both modalities must exist within the same domain.

Translating MR images to X-ray images is an inherently ill-posed problem due to fundamental physical differences:

  1. Signal Mismatch: Dense cortical bone yields a strong signal in X-ray but almost no signal in MRI. Conversely, air also yields no signal in MRI, creating an overlapping intensity range that makes distinguishing bone from air exceptionally difficult.
  2. Dimensionality Reduction: Unlike volumetric (3D) translation, projection imaging integrates 3D attenuation values along a path onto a 2D detector. This linear combination of overlapping structures obliterates depth information, significantly compounding the difficulty of synthesis.

Prior works focused almost exclusively on 3D volumetric translation (e.g., generating CT maps from MRI for radiotherapy). This paper addresses the unstudied challenge of direct 2D projection-to-projection translation.

Methods

The authors propose a Generative Adversarial Network (GAN) framework tailored specifically for medical projection data, modifying a standard feed-forward encoder-decoder architecture in two key ways:

  • High-Resolution Capacity Shift: Standard natural image generators place residual blocks at the lowest (coarse) resolution level to capture diverse global layouts. Because medical skull projections share a highly constrained global geometry, the authors instead distribute the residual blocks across the higher resolution levels. This shifts the network's capacity toward synthesizing fine, high-frequency details like bone outlines and sharp edges.
  • Bilinear Upscaling: Transposed convolutions were replaced with bilinear resizing followed by standard convolutions to eliminate checkerboard artifacts.
Figure 1: The proposed architecture for the generator network.
  • Edge-Weighted Objective Function: Standard pixel-wise losses ($L_1$ or $L_2$) yield blurry results. To combat this, the authors combined an adversarial loss and a VGG-19 feature-matching loss, and then multiplied the total objective by a gradient map ($E_L$) computed from the ground-truth image using a Sobel filter. This forces the network to heavily penalize errors around structural edges while attenuating the loss in large, homogeneous regions.

Datasets

The method was trained and evaluated using a clinical dataset consisting of paired MRI and CT scans from four human subjects exhibiting different pathologies.

  • To create ground-truth X-ray projections, the 3D CT volumes were forward-projected using the open-source CONRAD framework, simulating a standard $180^\circ$ transversal rotation geometry typical of clinical C-arm X-ray systems.
  • The model was validated using a 4-fold cross-validation strategy (training on three patients, testing on the remaining one).

Key Insights and Ideas

  • Domain Capacity Realignment: A core "aha" moment is that network architectures designed for natural images (like style transfer networks) waste capacity trying to learn where a head or background is. In medical imaging, spatial variance is low, so moving residual blocks to higher resolutions allows the network to focus entirely on texture and edge synthesis.
  • Anatomy-Driven Error Fluctuations: The authors discovered that the model's performance metrics (MSE and SSIM) fluctuate rhythmically based on the projection angle. When projection rays pass laterally through the skull ($45^\circ$ and $135^\circ$), the resulting images contain large, homogeneous brain regions that are easier for the network to synthesize. Conversely, frontal or rear views ($90^\circ$ and $180^\circ$) project highly complex, overlapping high-frequency structures (jawbone, eye sockets), causing a natural spike in synthesis error.

Key Results

The proposed edge-weighted architecture demonstrated clear quantitative and qualitative improvements over the standard baseline architecture:

Quantitative Performance

As shown in the paper's evaluations, adding the edge-weighting mechanism significantly optimized all primary metrics:

Metric Reference Architecture (Baseline) Ours (w/o edge-weighting) Ours (w/ edge-weighting)
MSE ($\downarrow$) $0.010 \pm 0.004$ $0.009 \pm 0.002$ $\mathbf{0.006 \pm 0.003}$
SSIM ($\uparrow$) $0.889 \pm 0.015$ $0.884 \pm 0.011$ $\mathbf{0.898 \pm 0.015}$
PSNR ($\uparrow$) $20.22 \pm 1.78\text{ dB}$ $20.50 \pm 1.14\text{ dB}$ $\mathbf{22.49 \pm 2.03\text{ dB}}$

Qualitative Performance

  • The baseline model suffered from severe blurriness and generated artifacts described as "unnatural holes in the brain."
  • The edge-weighted model successfully recovered sharp bone boundaries, particularly at the complex base of the skull, yielding synthesized images visually indistinguishable from true fluoroscopic X-rays.
Evaluation metrics and synthesized projection examples across a circular trajectory.

Limitations and Future Work

The primary limitation acknowledged by the authors is the small sample size (four patient datasets), which restricts the network's exposure to diverse patient-specific pathologies.

Furthermore, a fundamental physical limitation remains: purely X-ray-sensitive features cannot be translated. For instance, metallic interventional devices (like catheters or stents) do not appear in MR projections. If they are not visible in the source domain, the network cannot synthesize them into the target X-ray domain. The authors note that developing methods to handle or integrate this missing device information is a vital direction for future work.

Summary updated

Abstract

The potential benefit of hybrid X-ray and MR imaging in the interventional environment is large due to the combination of fast imaging with high contrast variety. However, a vast amount of existing image enhancement methods requires the image information of both modalities to be present in the same domain. To unlock this potential, we present a solution to image-to-image translation from MR projections to corresponding X-ray projection images. The approach is based on a state-of-the-art image generator network that is modified to fit the specific application. Furthermore, we propose the inclusion of a gradient map in the loss function to allow the network to emphasize high-frequency details in image generation. Our approach is capable of creating X-ray projection images with natural appearance. Additionally, our extensions show clear improvement compared to the baseline method.
BibTeX
@misc{stimpel2018projection,
  author = {Bernhard Stimpel and Christopher Syben and Tobias Würfl and Katharina Breininger and Katrin Mentl and Jonathan M. Lommen and Arnd Dörfler and Andreas Maier},
  title = {{Projection image-to-image translation in hybrid X-ray/MR imaging}},
  year = {2018},
  eprint = {1804.03955},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/1804.03955},
}