Progress on the development of the collinear laser spectroscopy setup for the study of unstable nuclei

Peng Zhang, Yinshen Liu, Shiwei Bai, X. F. Yang, Shujing Wang, Yongchao Liu, Han-Rui Hu, Yangfan Guo, Zhe-Yang Lin, Yan Zhou, Zeyu Du, Wen-Cong Mei, Yanlin Ye, Q. T. LiChinese 2022 · DOI

Abstract

<p indent="0mm">The basic properties of unstable nuclei are very sensitive probes for the study of exotic nuclear structures, which is of importance for an in-depth understanding of the unexpected structure phenomena in atomic nuclei with large proton-to-neutron ratios. Collinear laser spectroscopy (CLS) techniques have been proven to be a powerful tool to determine simultaneously multiple fundamental properties of ground and long-lived isomeric states of exotic nuclei, such as nuclear spins, electromagnetic moments and charge radii, by measuring the subtle hyperfine structure and isotope shifts in a nuclear model-independent manner. The studies of nuclear properties and structures of unstable nuclei using laser spectroscopy have been broadly carried out at ISOL (Isotope Separator On-Line) -type radioactive ion beam (RIB) facilitates, such as ISOLDE at CERN, IGISOL at JYFL and ISAC at TRIUMF, where the low energy RI beam is directly offered with high-quality. With the goal to explore more exotic nuclei, laser spectroscopy techniques, with their continuous technological development towards higher resolution and higher sensitivity, have been broadly established and planned at current- and next-generation RIB facilities worldwide. This CLS technique, however, has not yet been implemented at current operational domestic RIB facilities, the PF (Projectile Fragmentation)-type HIRFL at IMP and the BRIF (ISOL-type) at CIAE, for the studies of nuclear properties of unstable nuclei. Thus, we have recently developed a fluorescence-detection-based CLS system, which has been commissioned with stable ion beam produced from an offline laser ablation ion source and radioactive ion beam from BRIF RIB facility. In this paper, we briefly introduce the recent progress on the development of laser spectroscopy techniques at RIB facilities worldwide, as well as the experimental methods to measure the hyperfine structure spectra. Subsequently, the details of the CLS system recently developed, are presented together with recent upgrades and offline test. The optimization and upgrade of this system, include the lens rotator system for laser spot control, ion beam imaging using a phosphor screen, and calibration of the neutralization efficiency of the change exchange process. Based on these upgrades, we performed the offline test experiment using stable Ca and Ti beams. The optical spectra for the <inline-formula id="INLINE28"><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mrow><mml:mn>4</mml:mn><mml:mstyle mathvariant="normal"><mml:mi>s</mml:mi></mml:mstyle><mml:mo>⁢</mml:mo><mml:mtext> </mml:mtext><mml:mmultiscripts other="0"><mml:mstyle mathvariant="normal" other="0"><mml:mrow other="0"><mml:mi other="0">S</mml:mi></mml:mrow></mml:mstyle><mml:mprescripts other="1"/><mml:none other="1"/><mml:mrow other="1"><mml:mn other="1">2</mml:mn></mml:mrow></mml:mmultiscripts><mml:msub other="0"><mml:mrow other="0"/><mml:mrow other="1"><mml:mn other="1">1</mml:mn><mml:mo other="1">/</mml:mo><mml:mn other="1">2</mml:mn></mml:mrow></mml:msub><mml:mo>→</mml:mo><mml:mn>4</mml:mn><mml:mstyle mathvariant="normal"><mml:mi>p</mml:mi></mml:mstyle><mml:mo>⁢</mml:mo><mml:mtext> </mml:mtext><mml:mmultiscripts other="0"><mml:mstyle mathvariant="normal" other="0"><mml:mrow other="0"><mml:mi other="0">P</mml:mi></mml:mrow></mml:mstyle><mml:mprescripts other="1"/><mml:none other="1"/><mml:mrow other="1"><mml:mn other="1">2</mml:mn></mml:mrow></mml:mmultiscripts><mml:msub other="0"><mml:mrow other="0"/><mml:mrow other="1"><mml:mn other="1">3</mml:mn><mml:mo other="1">/</mml:mo><mml:mn other="1">2</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> ionic transition of <sup>40</sup>Ca<sup>+</sup> and for the <inline-formula id="INLINE29"><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mrow><mml:mn>3</mml:mn><mml:msup other="0"><mml:mstyle mathvariant="normal" other="0"><mml:mrow other="0"><mml:mi other="0">d</mml:mi></mml:mrow></mml:mstyle><mml:mrow other="1"><mml:mn other="1">2</mml:mn></mml:mrow></mml:msup><mml:mn>4</mml:mn><mml:msup other="0"><mml:mstyle mathvariant="normal" other="0"><mml:mrow other="0"><mml:mi other="0">s</mml:mi></mml:mrow></mml:mstyle><mml:mrow other="1"><mml:mn other="1">2</mml:mn></mml:mrow></mml:msup><mml:mo>⁢</mml:mo><mml:mtext> </mml:mtext><mml:mmultiscripts other="0"><mml:mstyle mathvariant="normal" other="0"><mml:mrow other="0"><mml:mi other="0">F</mml:mi></mml:mrow></mml:mstyle><mml:mprescripts other="1"/><mml:none other="1"/><mml:mrow other="1"><mml:mn other="1">3</mml:mn></mml:mrow></mml:mmultiscripts><mml:msub other="0"><mml:mrow other="0"/><mml:mrow other="1"><mml:mn other="1">2</mml:mn></mml:mrow></mml:msub><mml:mo>→</mml:mo><mml:mn>3</mml:mn><mml:msup other="0"><mml:mstyle mathvariant="normal" other="0"><mml:mrow other="0"><mml:mi other="0">d</mml:mi></mml:mrow></mml:mstyle><mml:mrow other="1"><mml:mn other="1">3</mml:mn></mml:mrow></mml:msup><mml:mn>4</mml:mn><mml:mstyle mathvariant="normal"><mml:mi>p</mml:mi></mml:mstyle><mml:mo>⁢</mml:mo><mml:mtext> </mml:mtext><mml:mmultiscripts other="0"><mml:mstyle mathvariant="normal" other="0"><mml:mrow other="0"><mml:mi other="0">D</mml:mi></mml:mrow></mml:mstyle><mml:mprescripts other="1"/><mml:none other="1"/><mml:mrow other="1"><mml:mn other="1">3</mml:mn></mml:mrow></mml:mmultiscripts><mml:msub other="0"><mml:mrow other="0"/><mml:mrow other="1"><mml:mn other="1">1</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> atomic transition of <sup>48</sup>Ti were obtained, giving a spectral linewidth of approximately <sc>55 MHz</sc> for Ca and <sc>65 MHz</sc> for Ti. The total detection sensitivity estimated in the case of <sup>40</sup>Ca<sup>+</sup> is comparable to that of the well-established CLS setups worldwide. Finally, a summary and outlook on the further development of the collinear resonance ionization spectroscopy towards higher sensitivity are given, which will be used at the current and future RIB facilities in China for the study of unstable nuclei with shorter half-lives and lower production yield. Further implementation of the UC<sub>x</sub> target into the BRIF facility is currently on-going, which will potentially produce more exotic isotopes at different mass regions. Development and installation of a radiofrequency quadrupole cooler and buncher are also on-going, which could provide bunched ion beams with low energy spread of few electron volts, being essential for the high resolution and high sensitivity measurement of unstable nuclei using CLS.
BibTeX
@inproceedings{zhang2022progress,
  author = {Peng Zhang and Yinshen Liu and Shiwei Bai and X. F. Yang and Shujing Wang and Yongchao Liu and Han-Rui Hu and Yangfan Guo and Zhe-Yang Lin and Yan Zhou and Zeyu Du and Wen-Cong Mei and Yanlin Ye and Q. T. Li},
  title = {{Progress on the development of the collinear laser spectroscopy setup for the study of unstable nuclei}},
  booktitle = {Chinese},
  year = {2022},
  doi = {10.1360/tb-2022-1116},
}

Loading related content...

Figure