NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Precision measurement of cardiac structure and function in cardiovascular magnetic resonance using machine learning

Rhodri Davies, João B. Augusto, Anish Bhuva, Hui Xue, Thomas A. Treibel, Yang Ye, Rebecca Hughes, Wenjia Bai, Clement Lau, Hunain Shiwani, Marianna Fontana, Rebecca Kozor, Anna S Herrey, Luís R. Lopes, Viviana Maestrini, Stefania Rosmini, Steffen E. Petersen, Peter Kellman, Daniel Rueckert, John P. Greenwood, Gabriella Captur, Charlotte Manisty, Erik B. Schelbert, James MoonJournal of Cardiovascular Magnetic Resonance 2022

Abstract

We present a fully automated algorithm for measuring left ventricular (LV) structure and global systolic function that betters human performance for speed and precision.

Introduction

Cardiovascular Magnetic Resonance (CMR) is the gold standard for assessing heart structure and function, particularly the Left Ventricular Ejection Fraction (LVEF). However, manual analysis creates a significant bottleneck. Expert clinicians must manually trace heart boundaries, a process that is time-consuming and prone to subjective variability.

While most AI research focuses on "accuracy"—matching human labels—this study prioritizes precision (reproducibility). By ensuring that repeated scans of the same patient yield consistent results, machine learning (ML) can detect smaller clinical changes and reduce the sample sizes required for clinical trials.

Methodology

The researchers developed a pipeline using four Convolutional Neural Networks based on the U-Net architecture.

Automated segmentation of the left ventricle showing the blood pool (red) and myocardium (yellow).

Key technical features include:

  • Dilated Convolutions: These allow the model to capture multi-scale context without sacrificing spatial resolution.
  • Spatial Normalization: Images are standardized by centering, rotating, and scaling to a reference frame.
  • Mitral Annular Plane Correction: To solve the challenge of the "basal slice" (where the heart meets the atrium), the model uses long-axis views to mathematically define a trimming plane for consistent volume calculation.
Long-axis view with markers used for Mitral Annular Plane Correction to define the basal slice.
  • Iterative Refinement: An active learning loop was used to identify and correct errors in the training data, emphasizing a data-centric approach to model improvement.

Datasets and Generalizability

The model was trained and tested on a massive, multi-institutional dataset:

  1. Training Set: 1,923 patients from 13 institutions across 3 countries, covering 10 scanner models and 9 clinical conditions.
  2. Precision Dataset: 109 patients underwent scan-rescan protocols to benchmark reproducibility.
  3. Generalizability Dataset: 1,277 consecutive real-world patients from an independent center to test performance on uncurated data.

Key Results

The ML pipeline demonstrated clear superiority over manual human analysis and existing commercial software:

  • Efficiency: Analysis time dropped from a median of 13 minutes for humans to just 20 seconds for the machine.
  • Precision: In scan-rescan tests, the ML algorithm achieved a lower Coefficient of Variation (CoV) for LVEF (4.2% vs. 6.0%) and LV Mass (3.6% vs. 4.8%).
  • Reliability: The mis-segmentation rate was remarkably low at 1 in 479 images, significantly better than the commercial benchmark (1 in 57).
  • Clinical Impact: Due to increased precision, clinical trials using LVEF as an endpoint could reduce their required sample size by up to 46%.

Discussion and Limitations

While the results are transformative, some challenges remain. Breath-hold inconsistencies can lead to slice misalignment that the current 3D co-registration struggles to fix. Additionally, the model's performance on rare pathologies (like laminar thrombus) or congenital heart diseases requires further validation. Future work will involve multi-center human benchmarking to further solidify these findings as the new standard for cardiac imaging analysis.

Summary updated

BibTeX
@article{davies2022precision,
  author = {Rhodri Davies and João B. Augusto and Anish Bhuva and Hui Xue and Thomas A. Treibel and Yang Ye and Rebecca Hughes and Wenjia Bai and Clement Lau and Hunain Shiwani and Marianna Fontana and Rebecca Kozor and Anna S Herrey and Luís R. Lopes and Viviana Maestrini and Stefania Rosmini and Steffen E. Petersen and Peter Kellman and Daniel Rueckert and John P. Greenwood and Gabriella Captur and Charlotte Manisty and Erik B. Schelbert and James Moon},
  title = {{Precision measurement of cardiac structure and function in cardiovascular magnetic resonance using machine learning}},
  journal = {Journal of Cardiovascular Magnetic Resonance},
  year = {2022},
  doi = {10.1186/s12968-022-00846-4},
}
Figure