Precision 1070 nm Ultrafast Laser-induced Photothrombosis (PLP) of Depth-targeted Vessels in vivo

Liang Zhu, Mengqi Wang, Peng Fu, Yin Liu, Hequn Zhang, Anna Wang Roe, Xi WangbioRxiv 2022

TL;DR

Researchers have developed a new method called Precision Ultrafast Laser-induced Photothrombosis (PLP) that uses a 1070 nm laser to precisely and quickly block individual blood vessels in the brain. This technique, combined with two-photon microscopy, offers a powerful tool for studying brain vascular function and diseases in vivo.

What Problem Does This Paper Address?

Understanding the intricate network of blood vessels in the brain (the cerebrovasculature) is crucial for comprehending how the brain functions in health and disease. To study how these vessels malfunction, researchers often need to selectively block specific vessels. However, existing methods for inducing blood clots (photothrombosis) in the brain face challenges with accuracy, especially when targeting vessels at different depths within the brain tissue, and can sometimes affect nearby vessels. This paper aims to address these limitations by developing a more precise and controllable method for single-vessel occlusion in the cerebral cortex.

Methods

The core of this research is the development of Precision Ultrafast Laser-induced Photothrombosis (PLP). This technique utilizes an ultrafast laser, specifically at a wavelength of 1070 nm, to induce a blood clot in a targeted blood vessel.

Here's a breakdown of the key methods:

  • Rose Bengal (RB) as a Photosensitizer: RB is a dye that, when exposed to specific wavelengths of light, generates reactive oxygen species (ROS). These ROS trigger platelet aggregation and the formation of a blood clot.
  • Ultrafast Laser Excitation: Instead of traditional green light, the researchers use ultrafast lasers (720-1070 nm) to excite the RB. This allows for non-linear absorption, meaning the laser light is absorbed more efficiently at the focal point, leading to greater precision and reduced damage to surrounding tissues.
  • Raster Scan vs. Spiral Scan:
    • Raster Scan: Initially, the researchers explored using a raster scan (back-and-forth pattern) with various laser wavelengths (720-1070 nm) to induce photothrombosis. This method showed varying success rates depending on depth and wavelength.
  • Spiral Scan (PLP): The novel approach developed here is the spiral scan. This method uses a 1070 nm ultrafast laser to scan in a spiral pattern within the vessel's lumen. This technique is designed to be more efficient, minimize thermal damage, and improve depth penetration.
  • Two-Photon Laser Scanning Microscopy (TPLSM): TPLSM is used in conjunction with PLP. It allows for real-time imaging of the blood vessels and the clot formation process at high resolution and depth. A 920 nm laser is used for imaging, while the 1070 nm laser is used for photothrombosis.
  • In Vivo Experiments: The studies were conducted in mice, allowing for the observation of vascular function and occlusion in a living organism. Experiments were performed on both anesthetized and awake mice.

Datasets

Not discussed in the paper. The study relies on experimental data collected from live mice.

Key Insights and Ideas

  • 1070 nm Wavelength Advantage: The 1070 nm wavelength proved to be particularly effective for deep tissue penetration and efficient photothrombosis, showing good success rates even at depths of 380-400 µm.
  • Spiral Scan Superiority: The spiral scan method significantly outperformed the raster scan for inducing photothrombosis, especially in deeper cortical layers. It demonstrated higher success rates and faster occlusion times.
  • Precision and Depth Selectivity: The PLP method, particularly with the spiral scan, offers remarkable precision, allowing researchers to target and occlude single vessels without affecting adjacent ones. This is crucial for studying localized vascular dysfunction.
  • Real-time Monitoring: The integration with TPLSM allows for real-time visualization of the entire photothrombosis process, from clot formation to complete occlusion.
  • Applicability to Awake Animals: The ability to perform PLP in awake mice is a significant advantage, as it eliminates confounding factors introduced by anesthesia and allows for the study of vascular responses under more natural physiological conditions.

Key Results

  • Raster Scan Performance: At superficial depths (80-100 µm), raster scans achieved success rates above 78% for all tested wavelengths (720-1070 nm) with 80 mW laser power. However, at deeper layers (380-400 µm) and higher power (140 mW), success rates dropped significantly, especially for shorter wavelengths, with 1000 nm and 1070 nm showing better reliability.
  • Spiral Scan Performance: The spiral scan method demonstrated a high success rate of 90% for capillary photothrombosis at depths of 380-400 µm, significantly outperforming the raster scan (56.25%) at the same depth.
  • Occlusion Time: Spiral scans resulted in significantly shorter occlusion times (around 68 seconds) compared to raster scans (around 153 seconds) for successful occlusions.
  • Versatility: The PLP approach was successfully applied to various vessel types (pial arteries, parenchymal arterioles, capillaries) and depths (up to 794 µm) in both anesthetized and awake mice.
  • High Success Rates: Overall, the PLP method achieved high success rates across different vessel types and depths, with some capillary occlusions reaching over 97% success.

Limitations and Future Work

  • BBB Leakage: While generally minimized, BBB leakage was observed in a few capillaries, particularly with shorter wavelengths during raster scans. The spiral scan method appears to further reduce this issue.
  • Wavelength Optimization: While 1070 nm showed good performance, further systematic quantification of ROS production and its correlation with fluorescence emission across different wavelengths could refine the understanding of optimal excitation parameters.
  • Thermal Damage: Although the spiral scan is designed to minimize thermal damage, the paper acknowledges that constant scanning on the ROI could still lead to heat build-up. The proposed 3s scan/2s imaging paradigm aims to mitigate this.
  • Future Work: The authors suggest that further studies could systematically quantify fluorescence emission and ROS generation to better understand the efficiency of ultrafast laser-induced RB excitation. The PLP method's application to study cerebral small vessel disease (CSVD) and neurodegeneration is also highlighted as a promising future direction.

Summary updated

Abstract

Abstract The cerebrovasculature plays an essential role in neurovascular and homeostatic functions in health and disease conditions. Many efforts have been made for developing vascular thrombosis methods to study vascular dysfunction in vivo , while technical challenges remain, such as accuracy and depth-selectivity to target single vessel in the cerebral cortex. Herein, we first demonstrates the evaluation and quantification of the feasibility and effects of Rose Bengal (RB)-induced photothrombosis with 720-1070 nm ultrafast lasers in raster scan. A flexible and reproducible approach is then proposed to employ a 1070 nm ultrafast laser with spiral scan for producing RB-induced occlusion, which is described as precision ultrafast laser-induced photothrombosis (PLP). Combine with two-photon microscopy imaging, this PLP displays highly precise and fast occlusion induction of various vessel types, sizes, and depths, which enhances the precision and power of the photothrombosis protocol. Overall, the PLP method provides a real-time, practical, precise, and depth-selected single-vessel photothrombosis technology in cerebral cortex with commercially available optical equipment, which is crucial for exploring brain vascular function with high spatial temporal resolution in brain.
BibTeX
@misc{zhu2022precision,
  author = {Liang Zhu and Mengqi Wang and Peng Fu and Yin Liu and Hequn Zhang and Anna Wang Roe and Xi Wang},
  title = {{Precision 1070 nm Ultrafast Laser-induced Photothrombosis (PLP) of Depth-targeted Vessels <i>in vivo</i>}},
  year = {2022},
  doi = {10.1101/2022.06.22.497150},
  howpublished = {bioRxiv},
}
Figure