Porous-Structure Flexible Muscle Sensor for Monitoring Muscle Function and Mass

Hongyu Zhang, Keer Wang, Jiao Suo, Clio Yuen Man Cheng, Meng Chen, King Wai Chiu Lai, Calvin Kalun Or, Yong Hu, Vellaisamy A. L. Roy, Cindy Lo Kuen Lam, Ning Xi, Vw Lou, Wen J. LiACS 2025 · DOI

TL;DR

This paper introduces a novel, low-cost, flexible, and porous CNT/PDMS piezoresistive sensor for non-invasively monitoring muscle function and mass. The sensor achieves high accuracy in distinguishing between elderly and young individuals and can predict skeletal muscle mass with a low error rate, offering a promising tool for early detection of age-related muscle decline.

What Problem Does This Paper Address?

Age-related muscle loss, known as sarcopenia, significantly impacts health and mobility, increasing the risk of falls and other complications. Early detection and intervention are crucial, but current clinical methods for assessing muscle function and mass are often complex, expensive, and not suitable for daily monitoring. Techniques like CT, MRI, and DEXA require specialized equipment and trained personnel, limiting their accessibility. This paper aims to bridge this gap by developing a cost-effective, user-friendly, and wearable sensor system that can provide continuous, at-home monitoring of muscle health.

Methods

The core of this work is a novel porous-structure flexible piezoresistive sensor fabricated from a carbon nanotube (CNT)/polydimethylsiloxane (PDMS) nanocomposite. The porous architecture is created using a sugar cube as a sacrificial template, which significantly enhances the sensor's sensitivity and flexibility. This design allows the sensor to conform closely to the skin and adapt to body movements without compromising performance.

The sensor's working principle relies on the tunneling effect: applied mechanical strain (from muscle deformation) alters the distance between CNTs, changing the composite's resistance. This resistance change is measured as a voltage signal.

For data analysis, a multi-stage approach was employed:

  • Muscle Cycle Analysis: A YOLO-V5m model was used to automatically segment the muscle activity data into individual gait cycles, achieving over 90% accuracy.
  • Feature Extraction: Data from the segmented cycles were processed through low-pass and high-pass filtering to extract features from the raw signal, MMG (mechanomyography), and frequency domain (FD) data. This resulted in 30 distinct features.
  • Muscle Function Evaluation:
    • Supervised Learning: Various machine learning algorithms (SVM, Adaboost, Decision Tree, Random Forest, KNN) were trained on the extracted features to classify participants into "elderly" and "young" age groups.
  • Unsupervised Learning: t-Distributed Stochastic Neighbor Embedding (t-SNE) was used for dimensionality reduction, followed by K-means clustering to validate the classification of age groups.
  • Muscle Mass Estimation: An Adaboost regression model was trained using the extracted features to predict the relative skeletal muscle mass index (RSMI).

Datasets

The study utilized data collected from 23 participants, comprising 12 healthy elderly subjects (over 65) and 11 young adults (20-30 years old). The data consisted of 4-meter walking tests, with each participant performing multiple trials. The collected data was split into training (70%) and testing (30%) sets for both muscle function and muscle mass analysis. No new benchmark datasets were introduced; rather, existing data collection protocols were adapted for the novel sensor.

Key Insights and Ideas

  • Porous Architecture is Key: The innovative porous structure of the CNT/PDMS sensor is crucial for achieving both high sensitivity and excellent flexibility, overcoming limitations of traditional rigid sensors.
  • Cost-Effectiveness: The sensor's material cost is remarkably low (under 10 HKD), making it highly accessible for widespread adoption.
  • Dual-Stage Sensitivity: The sensor exhibits different sensitivities in different pressure ranges, allowing for precise detection of both subtle and significant muscle movements.
  • Robustness to Environment: The sensor's performance is largely unaffected by body temperature and humidity, which are common challenges for wearable electronics.
  • YOLO-V5m for Gait Segmentation: Utilizing a computer vision model (YOLO-V5m) for segmenting muscle activity data into gait cycles is an effective and automated approach, reducing manual effort and potential errors.
  • MMG Features are Dominant for Function: The study found that MMG features were more important than FD or LPF features for evaluating muscle function, highlighting the significance of muscle vibration signals.

Key Results

  • Muscle Function Classification:
    • Supervised learning achieved a maximum accuracy of 93.48% in distinguishing between elderly and young subjects using the Adaboost algorithm.
  • Unsupervised learning (t-SNE + K-means) demonstrated a classification accuracy of 82.71% with 30 features and 78.2% with 2D features, validating the sensor's ability to differentiate age groups.
  • Muscle Mass Prediction:
    • The Adaboost regression model predicted the relative skeletal muscle mass index (RSMI) with an average prediction error of 2.8% (2.9% for elderly, 2.7% for young).
  • Sensor Performance:
    • Linear detection range: 0-39 kPa.
  • Dual-stage sensitivities: 0.03398 kPa⁻¹ (0-7 kPa) and 0.000922 kPa⁻¹ (7-39 kPa).
  • Stable performance for over a week.
  • Fast response (0.12 ms) and recovery (0.15 ms) times.
  • Low limit of detection (LOD) of 0.0229 kPa.

Limitations and Future Work

  • Limited Sample Size: While 23 participants is a good start, a larger and more diverse cohort would further strengthen the generalizability of the findings.
  • Specific Muscle Group: The study focused on the gastrocnemius muscle. Future work could explore sensor placement on other muscle groups to provide a more comprehensive assessment of overall muscle health.
  • Real-world Validation: While tested indoors, further validation in diverse real-world environments (e.g., outdoor activities, different weather conditions) would be beneficial.
  • Long-term Clinical Studies: The authors suggest that the sensor has significant potential for the daily monitoring of muscle function and mass, enabling early detection and prevention of sarcopenia and other muscle-related disorders. This implies a need for longer-term clinical studies to demonstrate its impact on patient outcomes.
  • Integration with Other Sensors: The paper mentions the potential for integration with other wearable sensors, which could lead to more sophisticated multi-modal health monitoring systems.

Summary updated

Abstract

Muscle function and composition are important indicators of age-related health. However, current assessment methods are often complex and expensive, making the early detection of related problems difficult. Therefore, developing a cost-effective and easily accessible daily based detection method is an essential research focus. This study introduces a novel portable porous-structured (i.e., CNT/PDMS nanocomposite) and flexible piezoresistive sensor for evaluating muscle function and relative skeletal muscle mass index, offering advantages of cost-effectiveness, safety, and user-friendliness. The porous architecture significantly enhances sensitivity, while the flexible design ensures excellent conformability to the skin and adaptability to complex body movements. The prototype sensor demonstrates a linear detection range of 0-39 kPa with dual-stage sensitivities of 0.03398 kPa<sup>-1</sup> (0-7 kPa) and 0.000922 kPa<sup>-1</sup> (7-39 kPa). The sensor maintains stable performance for over a week and exhibits reliable operation unaffected by body temperature or perspiration, and the material cost does not exceed 10 HKD. The gait data can be easily collected by wearing the sensor on the left gastrocnemius muscle. Our study encompassed 23 participants from both the elderly and young age groups. The supervised learning achieved a maximum accuracy of 93.48% in distinguishing between the elderly and the young subjects. Unsupervised learning analysis further validated the efficacy of our flexible sensor in muscle function assessment. Additionally, an Adaboost regression model was employed to predict the relative skeletal muscle mass index, achieving a mean error of 2.8%. This flexible sensor demonstrates significant potential for the daily monitoring of muscle function and mass, enabling early detection and prevention of sarcopenia and other muscle-related disorders. Its wearable and noninvasive characteristics make it an attractive solution for muscle assessment in clinical, sports, and home environments.