Plasma-Modified, Epitaxial Fabricated Graphene on SiC for the Electrochemical Detection of TNT

Scott A. Trammell, Sandra C. Hernández, Rachael L. Myers‐Ward, Daniel Zabetakis, David A. Stenger, D. Kurt Gaskill, Scott G. Walton2016

TL;DR

Researchers have developed a new method for detecting the explosive trinitrotoluene (TNT) with enhanced sensitivity using plasma-modified graphene. By introducing oxygen or nitrogen functionalities onto epitaxial graphene grown on silicon carbide, they achieved a significant improvement in electrochemical detection, paving the way for low-cost, high-volume sensor production.

What Problem Does This Paper Address?

Detecting explosives like TNT is crucial for security and safety. While graphene is a promising material for sensors due to its surface properties, its inherent sensitivity can be a double-edged sword, leading to interference from non-target substances. Furthermore, existing methods for detecting TNT electrochemically often require complex pre-concentration steps or are limited in their scalability for practical, widespread applications. This paper aims to address these limitations by developing a more sensitive and industrially viable graphene-based sensor for TNT detection.

Methods

The core of this research lies in the plasma functionalization of epitaxial graphene (EG) grown on silicon carbide (SiC) substrates.

  • Epitaxial Graphene Growth: High-quality, large-area epitaxial graphene was synthesized on Si-face, on-axis 6H-SiC substrates via silicon sublimation at high temperatures (1540 °C) in a commercial CVD reactor. This method is known for producing uniform graphene layers suitable for large-scale applications.
  • Plasma Functionalization: The EG surface was then chemically modified using electron-beam generated plasmas. This technique is advantageous for processing atomically thin materials over large areas. The plasmas were generated using either oxygen (O2) or nitrogen (N2) mixed with argon (Ar) at varying pressures (25-90 mTorr) for a short duration (60 s). This process introduces oxygen or nitrogen-containing functional groups onto the graphene surface.
  • Surface Characterization: X-ray photoelectron spectroscopy (XPS) was used to analyze the chemical changes and bonding characteristics on the graphene surface before and after plasma treatment. This helped confirm the successful introduction and quantify the amount of oxygen and nitrogen functionalities.
  • Electrochemical Detection: Square wave voltammetry (SWV) was employed as the electroanalytical technique for TNT detection. SWV is chosen for its ability to minimize non-faradaic charging currents, leading to improved detection limits compared to traditional cyclic voltammetry. The experiments were conducted using a custom-designed electrochemical cell with the modified EG as the working electrode in a phosphate-buffered saline (PBS) solution.

Datasets

Not discussed in the paper. The study relies on experimental measurements using TNT solutions of varying concentrations.

Key Insights and Ideas

  • Plasma Functionalization is Key: The introduction of oxygen and nitrogen functionalities onto the graphene surface via plasma treatment dramatically enhances its electrochemical response to TNT. This is a significant improvement over unmodified graphene.
  • Oxygen Reigns Supreme (for TNT): While both oxygen and nitrogen functionalization improved TNT detection, the oxygen treatment yielded a more pronounced enhancement, leading to a significantly larger signal. This suggests that oxygen-containing groups are particularly effective at interacting with TNT for electrochemical detection.
  • Two-Site Binding for TNT: The electrochemical response of oxygen-modified graphene to TNT could be modeled using a two-site Langmuir isotherm. This implies that the modified graphene surface possesses distinct binding sites with varying affinities for TNT, allowing for both sensitive detection at low concentrations and a broad dynamic range.
  • Industrial Scalability: The combination of readily available epitaxial graphene growth on SiC and the rapid, large-area plasma processing technique makes this sensor fabrication method highly amenable to low-cost, high-volume industrial production.

Key Results

  • Enhanced Sensitivity: Oxygen-functionalized graphene showed a 6-fold increase in sensitivity towards TNT detection compared to unmodified graphene.
  • Improved Detection Limit (LOD): The study achieved an estimated Limit of Detection (LOD) of 20 ppb for TNT in PBS, based on an analytical standard signal-to-noise ratio (S/N) of 3. This was achieved without the need for pre-concentration steps.
  • Pronounced Signal: Oxygen-modified graphene exhibited a 10-fold larger cathodic peak current (Ipc) for TNT compared to nitrogen-functionalized samples.
  • Shifted Peak Potential: Both oxygen and nitrogen functionalization shifted the cathodic peak potential (Epc) for TNT reduction to less negative values, indicating a faster electron transfer rate and improved electrochemical performance. Oxygen modification showed a more significant shift.
  • Langmuir Isotherm Fit: The dose response curves for oxygen-functionalized graphene fit well to a two-site Langmuir isotherm, suggesting the presence of multiple binding sites with different affinities for TNT.

Limitations and Future Work

  • Interference: While the paper focuses on TNT detection, the inherent sensitivity of graphene can still lead to potential interference from other analytes present in complex environmental samples. The authors mention that the less negative Epc with oxygen modification might decrease resistance to interference with oxygen, but further investigation into cross-reactivity with other common interferents is needed.
  • Real-World Application: The current study was performed in a controlled laboratory environment using PBS buffer. Future work should focus on testing the sensor's performance in more complex matrices, such as soil or water samples, to assess its robustness and practical applicability.
  • Optimization of Functionalization: While oxygen functionalization showed superior results for TNT, further optimization of plasma parameters (pressure, gas composition, duration) could potentially lead to even greater sensitivity or selectivity for specific analytes.
  • Long-Term Stability: The long-term stability and reusability of the plasma-modified graphene sensors would be important considerations for practical deployment.

Summary updated

Abstract

Using square wave voltammetry, we show an increase in the electrochemical detection of trinitrotoluene (TNT) with a working electrode constructed from plasma modified graphene on a SiC surface vs. unmodified graphene. The graphene surface was chemically modified using electron beam generated plasmas produced in oxygen or nitrogen containing backgrounds to introduce oxygen or nitrogen moieties. The use of this chemical modification route enabled enhancement of the electrochemical signal for TNT, with the oxygen treatment showing a more pronounced detection than the nitrogen treatment. For graphene modified with oxygen, the electrochemical response to TNT can be fit to a two-site Langmuir isotherm suggesting different sites on the graphene surface with different affinities for TNT. We estimate a limit of detection for TNT equal to 20 ppb based on the analytical standard S/N ratio of 3. In addition, this approach to sensor fabrication is inherently a high-throughput, high-volume process amenable to industrial applications. High quality epitaxial graphene is easily grown over large area SiC substrates, while plasma processing is a rapid approach to large area substrate processing. This combination facilitates low cost, mass production of sensors.
BibTeX
@misc{trammell2016plasma,
  author = {Scott A. Trammell and Sandra C. Hernández and Rachael L. Myers‐Ward and Daniel Zabetakis and David A. Stenger and D. Kurt Gaskill and Scott G. Walton},
  title = {{Plasma-Modified, Epitaxial Fabricated Graphene on SiC for the Electrochemical Detection of TNT}},
  year = {2016},
  doi = {10.3390/s16081281},
}
Figure