This study validates Inertial Measurement Units (IMUs) and markerless motion capture against a gold-standard optoelectronic system for measuring 3D neck and trunk movements during a simulated surgery task. IMUs demonstrated good-to-excellent accuracy, making them a promising tool for ergonomic interventions in real-world surgical environments, while the markerless method showed limitations that need further improvement.

What Problem Does This Paper Address?

Surgeons are at a high risk of developing musculoskeletal symptoms (MSS) due to prolonged static postures, unfavorable working positions, and repetitive movements. Quantifying these movements in 3D is crucial for developing ergonomic interventions and preventive devices like exoskeletons. Traditional optoelectronic motion capture systems, while accurate, are impractical for the operating room (OR) due to their bulky nature and need for a controlled environment. This paper addresses the need for practical, wearable, and non-intrusive methods for capturing 3D neck and trunk kinematics in such settings, specifically evaluating Inertial Measurement Units (IMUs) and markerless motion capture as potential alternatives.

Methods

The study compared three motion capture systems:

  • Gold Standard: A VICON optoelectronic motion capture system with Nexus 2.12.1 software, using the Upper Body Plug-In-Gait model.
  • IMU-Based Method: Four XSens MTw inertial measurement units were placed on the head and trunk. Data was processed using MT manager software and OpenSim for inverse kinematics.
  • Markerless Method: A system using four video cameras (Panasonic HC-VX980 and Sony 4K FDR-AX53) was employed. DeepLabCut was used for pose estimation and Anipose for 3D coordinate prediction, with subsequent processing in OpenSim.

The validation involved two types of movement tasks:

  1. Single Plane (SP) Movements: Participants performed isolated neck and trunk flexion/extension, lateral bending, and rotation.
  2. Simulated Surgery Task: A more complex task involving simultaneous and repetitive neck and trunk movements in multiple planes, mimicking surgical actions like picking up and transferring small objects with forceps.

Statistical analysis included Intraclass Correlation Coefficient (ICC), Root Mean Square Error (RMSE), Range of Motion (ROM) difference, and Bland-Altman plots to assess accuracy and validity.

Datasets

The study did not introduce new datasets for training or evaluation. Instead, it utilized data collected from ten healthy participants performing specific movement tasks. The first trial of each participant's movement task was used for training the DeepLabCut model for the markerless method.

Key Insights and Ideas

  • IMUs are a viable alternative for surgical ergonomics: The study strongly supports the use of IMUs for capturing 3D neck and trunk kinematics in simulated surgical tasks, demonstrating good-to-excellent accuracy and validity comparable to the gold standard. This opens doors for real-time monitoring and feedback in the OR.
  • Markerless motion capture has potential but needs refinement: While markerless methods are attractive due to their non-intrusive nature, the current implementation showed limitations, particularly in accuracy for neck kinematics and in transverse plane movements. This suggests that while promising, further development in algorithms, camera setup, and marker point selection is needed.
  • Anatomical landmark definition is key for IMU validation: The researchers highlighted that placing markers on anatomical landmarks (rather than on the IMUs themselves) provided a more robust validation of IMU-based motion capture systems, even if it slightly increased RMSE.
  • Rotation angles are more challenging to capture accurately: Both IMU and markerless methods showed larger differences and RMSE for rotation angles compared to other movements, suggesting this is an area requiring further investigation and potentially more sophisticated modeling.

Key Results

  • IMU Method:
    • RMSE values were generally below 3 degrees, with a maximum of 4.7 degrees for trunk AR during SP-movements.
  • ROM differences were less than 3 degrees for most movements, with exceptions for trunk AR (5.0 degrees) and neck FE (5.4 degrees) during SP-movements.
  • ICC (2,1) values for ROM were excellent (0.90–0.99) for SP-movements and good-to-excellent (0.80–0.97) for simulated surgery tasks, indicating high reliability.
  • Markerless Method:
    • RMSE values were higher, ranging from 5.5 to 8.7 degrees during simulated surgery tasks, and up to 15.2 degrees for neck AR during SP-movements.
  • ROM differences were also larger, particularly for trunk AR (11.7 degrees) and neck AR (18.5 degrees) during SP-movements.
  • ICC (2,1) values were more variable, ranging from acceptable (0.42–0.70) to good (0.55–0.86) for trunk kinematics, but often lower for neck kinematics, indicating less consistent validity.

Limitations and Future Work

  • Sample Size and Participant Demographics: The study used a small sample size (n=10) of young, healthy participants, not actual surgeons. Future research should include a larger, more diverse sample, including medical staff in a real OR environment, to improve generalizability.
  • Synchronization: The use of sound signals for camera synchronization could be improved by employing cameras with built-in synchronization functions.
  • Markerless Model Training: The DeepLabCut model was trained on 200 frames, which might not capture rare movements, potentially leading to tracking errors. Training with more extensive datasets, including rare movements, is recommended.
  • Camera Setup for Markerless: The camera placement primarily in sagittal and frontal planes limited resolution in the transverse plane, impacting accuracy for AR movements. Optimizing camera placement and potentially using more cameras could enhance performance.
  • Tracking Point Features: Using eyebrows and chin as tracking points for the head segment might be less reliable than retroreflective markers. Suggestion to use "stickers" on the head for better recognition.
  • Camera Calibration Stability: The process of removing and reinserting SD cards might have slightly altered camera positions, potentially affecting triangulation accuracy.
  • Long-Term and Magnetic Field Effects: The study did not assess long-term motion capture or the influence of magnetic fields on IMU performance. Future work should investigate these aspects.
  • Trunk Rotation Estimation: The study identified challenges in accurately estimating trunk rotation angles with IMUs and suggests exploring more complex models for trunk segmentation.