Abstract
Coronary artery disease (CAD) is a significant health risk that requires early detection for effective treatment. While recent advances in deep learning have shown promise in automating CAD detection from coronary computed tomography angiography (CCTA) images, the accurate segmentation of coronary vessels remains a challenge, particularly due to the imbalanced presence of plaque in unhealthy vessels. This paper introduces a physiology-aware approach to coronary vessel segmentation that addresses these challenges. Our proposed pipeline consists of three main components: a hybrid UNeXt architecture for initial boundary prediction, multi-class circular convolution for iterative contour deformation, and a focal smooth L1 loss function to handle class imbalance. Extensive evaluations demonstrate that our methods significantly improve model performance, achieving state-of-the-art results in coronary vessel segmentation.
Introduction
Coronary Artery Disease (CAD) remains a leading cause of global mortality, primarily driven by plaque accumulation leading to arterial stenosis. Coronary Computed Tomography Angiography (CCTA) is the standard diagnostic tool, yet manual segmentation of vessel walls for stenosis measurement is labor-intensive and error-prone.
Automated segmentation faces two primary hurdles:
- Class Imbalance: Unhealthy vessels containing plaque exhibit complex morphologies that are significantly harder to segment than healthy vessels.
- Structural Consistency: Conventional models often treat the inner (lumen) and outer (vessel wall) boundaries as independent pixel sets, neglecting the physiological reality that these surfaces are physically linked and concentric.
Methodology
The proposed Physiology-aware PolySnake pipeline addresses these issues through a three-stage process involving initial contour generation and iterative refinement.
Hybrid UNeXt Backbone
To capture 3D spatial context while maintaining computational efficiency, the model utilizes a hybrid architecture. A 3D encoder learns spatial relationships between adjacent CCTA slices, while a 2D decoder predicts the initial vessel boundary contours ($C_0$).
Multi-class Circular Convolution
The core innovation is the "physiology-aware" multi-class circular convolution. Unlike standard models that deform a single boundary, this method processes the inner and outer boundaries simultaneously. By modeling the "tensile" relationship between the two walls, the system ensures they remain concentric and do not overlap, reflecting actual vessel anatomy.
Focal Smooth L1 Loss
To address the difficulty of segmenting plaque-heavy regions, a novel Focal Smooth L1 loss function is introduced. It down-weights "easy" healthy samples and forces the network to focus on "hard" samples with plaque. Additionally, a temperature parameter ($\tau$) limits the precision of initial contours, making the subsequent iterative refinement more robust against local minima.
Results and Discussion
The model was evaluated on a proprietary CCTA-CPR dataset comprising 33,676 training slices and 11,515 testing slices from 50 patients. The data included healthy slices as well as those with calcified and non-calcified plaque.
Quantitatively, the proposed method outperformed competitors like Deep Snake, DANCE, and E2EC. It achieved a macro-average Dice score of 77.6% and a significantly improved Hausdorff Distance (HD) of 5.524 (compared to 5.856 for the next best method). Qualitatively, as shown in the visual comparisons, the Physiology-aware PolySnake accurately traces the outer wall even in challenging cases of faint, non-calcified plaque where other models fail.
Conclusion
Physiology-aware PolySnake represents a significant step forward in automated CAD diagnosis. By integrating physiological constraints directly into the learning process and utilizing a robust loss function for imbalanced data, the system achieves state-of-the-art segmentation accuracy. Future work will focus on validating the model on multi-center public datasets and reducing dependency on pre-extracted artery centerlines.