Physics-Informed Modeling and Control of Multi-Actuator Soft Catheter Robots

Seyede Fatemeh Ghoreishi, Ryan D. Sochol, Dheeraj Gandhi, Axel Krieger, Mark D. FugeFrontiers Robotics AI 2021 · DOI · OpenReview

Introduction

Endovascular procedures represent a cornerstone of modern minimally invasive surgery, particularly for treating complex conditions like cerebral aneurysms. Navigating the "vascular highway" of the human brain requires extreme precision, as the path is characterized by sharp turns and intricate branching structures. Traditional micro-catheters are largely passive instruments, relying on a surgeon's manual skill in pushing, pulling, and twisting to reach deep-seated targets. This manual approach can lead to prolonged procedure times and potential vessel wall damage.

Anatomical context of cerebral aneurysms requiring precise endovascular navigation.

To address these challenges, researchers have proposed a new framework for active, multi-segmented soft robotic catheters. By equipping catheters with multiple pneumatic actuators, the device can change shape at various points along its length, allowing for safer and more efficient navigation through highly tortuous blood vessels.

Methodology

The core of this innovation is a two-part solution combining physics-informed modeling with optimization-based control. Rather than relying on computationally expensive Finite Element Analysis (FEA), the authors utilized Euler-Bernoulli beam theory to create a fast, analytical model of the catheter's kinematics.

Kinematic model of a multi-actuator soft catheter based on Euler-Bernoulli beam theory.

In this model, the catheter is treated as a continuous structure where each pneumatic segment bends into a constant curvature when pressurized. The framework calculates the exact $(x, y)$ coordinates of any point on the catheter body. To navigate, the system follows a "nominal trajectory" derived from pre-operative imaging (CT or MRI).

Control is managed through a non-linear constrained optimization problem solved by Genetic Algorithms (GA). At each step, the controller determines the optimal bending moments for each actuator and the necessary insertion depth. A critical safety feature is the inclusion of an integral term in the cost function that penalizes the entire catheter body if it drifts from the vessel centerline, effectively preventing collisions with delicate arterial walls.

Key Insights and Results

The study validated the framework using both specific clinical vessel geometries and procedurally generated "fractal trees" that mimic complex human vasculature.

  • The Necessity of Multi-Actuation: The research highlights that a single actuator is often insufficient for complex turns. Multi-actuator designs allow for "S-curves," which are essential when a branch turns in the opposite direction of its parent vessel.
  • Success Rates: In simulations involving complex branching structures, the success rate for reaching the target jumped from approximately 22% with a single-actuator design to 100% when using four actuators.
  • Precision and Safety: As the number of actuators increased, the "average discrepancy"—the distance the catheter drifts from the ideal centerline—decreased significantly. In the most complex scenarios, a 4-actuator catheter proved nearly twice as accurate as a 2-actuator version.

Conclusion and Future Directions

This framework serves as a "virtual test bench," allowing surgeons to simulate different catheter designs against a patient's specific anatomy before a procedure begins. While the current study is limited to 2D planes and ignores blood flow dynamics, it provides a robust foundation for future 3D models. The next phase of research involves incorporating torsional mechanics and validating these algorithms on physical soft robotic prototypes within silicone vascular models. By automating the navigation of the vascular maze, this technology promises to make endovascular surgery safer and more accessible.

Summary updated

Abstract

Catheter-based endovascular interventional procedures have become increasingly popular in recent years as they are less invasive and patients spend less time in the hospital with less recovery time and less pain. These advantages have led to a significant growth in the number of procedures that are performed annually. However, it is still challenging to position a catheter in a target vessel branch within the highly complicated and delicate vascular structure. In fact, vessel tortuosity and angulation, which cause difficulties in catheterization and reaching the target site, have been reported as the main causes of failure in endovascular procedures. Maneuverability of a catheter for intravascular navigation is a key to reaching the target area; ability of a catheter to move within the target vessel during trajectory tracking thus affects to a great extent the length and success of the procedure. To address this issue, this paper models soft catheter robots with multiple actuators and provides a time-dependent model for characterizing the dynamics of multi-actuator soft catheter robots. Built on this model, an efficient and scalable optimization-based framework is developed for guiding the catheter to pass through arteries and reach the target where an aneurysm is located. The proposed framework models the deflection of the multi-actuator soft catheter robot and develops a control strategy for movement of catheter along a desired trajectory. This provides a simulation-base...
BibTeX
@article{ghoreishi2021physics,
  author = {Seyede Fatemeh Ghoreishi and Ryan D. Sochol and Dheeraj Gandhi and Axel Krieger and Mark D. Fuge},
  title = {{Physics-Informed Modeling and Control of Multi-Actuator Soft Catheter Robots}},
  journal = {Frontiers Robotics AI},
  year = {2021},
  doi = {10.3389/frobt.2021.772628},
}
Figure