PhySA: Decoupling Aesthetic and Physical Rewards for Humanoid Locomotion

Yunwan Fu, Sicheng He, Jiageng Mao, Yue WangarXiv 2026

Training humanoid robots to walk smoothly is notoriously difficult. While Reinforcement Learning (RL) can produce functional gaits, they are often "jerky" and high-energy, leading to rapid hardware wear and tear. A new paper, PhySA: Decoupling Aesthetic and Physical Rewards for Humanoid Locomotion, reveals a surprising reason why modern AI-driven reward systems might be making this problem worse and proposes a dual-channel solution to fix it.

TL;DR

The authors discover that Vision-Language Models (VLMs) actually prefer jerky, high-acceleration robot movements, mistakenly perceiving them as "confident" motion. To solve this, they introduce PhySA, a framework that decouples aesthetic VLM feedback from physical smoothness penalties, achieving significantly smoother locomotion while reducing API costs by 24x.

What Problem Does This Paper Address?

In humanoid robotics, "smoothness" isn't just about looking good—it's a hardware requirement. High joint acceleration (jerk) draws more power and destroys actuators. Traditionally, engineers hand-tune "smoothness penalties," but this is tedious and often destabilizes early training.

Recently, researchers have turned to VLMs (like GPT-4o) to provide "aesthetic" rewards, assuming that what looks good to a VLM will be physically efficient. This paper challenges that assumption. The authors found that across four major VLMs, clips with higher joint acceleration consistently received higher aesthetic scores. To a VLM, a jerky, energetic gait looks like "purposeful" motion, while a smooth, low-amplitude gait looks "hesitant."

The VLM aesthetic channel and physical correction module pull the policy in opposite directions.

Methods

The authors propose PhySA (Physical Smoothness and Aesthetics), which splits the reward into two independent, independently removable channels:

  1. VLM Aesthetic Channel: An asynchronous module that queries GPT-4o every 200k steps. It provides a holistic score on gait qualities (like symmetry and posture) without blocking the training loop.
  2. Physical Correction Module: A phase-triggered system that monitors training statistics (like energy efficiency and stability). If the gait becomes too jerky or stagnates, it automatically edits the physical penalty weights in the simulator.

By keeping these separate, the system can enjoy the "holistic" gait improvements of a VLM without letting the VLM's bias toward high-energy motion ruin the robot's physical health.

PhySA end-to-end architecture showing the decoupled VLM and physical correction channels.

Datasets

The study primarily uses:

  • MuJoCo Humanoid-v5: The main environment for training and ablation studies.
  • AMASS: A large-scale motion capture dataset used to fit a Gaussian Motion Prior (GMP) to keep gaits within a naturalistic range.
  • IsaacLab & Unitree G1: Used to test cross-simulator and cross-embodiment transfer.

Key Insights and Ideas

  • The VLM Smoothness Paradox: There is a strong positive correlation (mean Pearson $r=+0.66$) between VLM aesthetic scores and joint acceleration. Using a VLM as a direct proxy for smoothness actually encourages worse physical behavior.
  • Decoupling is Essential: Because aesthetic preference and physical smoothness pull in opposite directions, they cannot be conflated into a single reward scalar.
  • Gait Specialization: PhySA doesn't just slow the robot down; it encourages "specialization." The policy learns to concentrate movement into a few key joints (like the hips) while holding others still, which is much more efficient than uniform deceleration.
  • The Integration Gap: A major reason rewards don't transfer between simulators (e.g., MuJoCo to Isaac) is the numerical integration timestep ($\Delta t$). A penalty weight that works for one $\Delta t$ can be $5\times$ too strong or weak for another.

Key Results

  • Smoothness Gains: In an extended run, PhySA reduced joint acceleration by 59.5% compared to the state-of-the-art Prompt2Policy baseline.
  • Efficiency: PhySA is significantly cheaper to run, requiring 24x fewer API calls than synchronous VLM reward methods, costing only about $0.85 per 10M training steps.
  • Ablation Proof: The authors showed that the VLM channel alone increases joint acceleration by 136%, proving that the physical correction module is the true driver of smoothness.
Figure 1: Left: In our main training run (a single run), PhySA reduces joint acceleration by 59.5% relative to Prompt2Policy at the same forward-velocity target; a three-seed replication gives a smaller, non-significant 7.2%. Center: The two channels pull in opposite directions: the aesthetic channel alone raises joint acceleration by 136%; the correction module alone reduces it by 29.8%. Right: PhySA issues 24× fewer VLM queries than a synchronous per-update scorer would (esti- mated from the number of policy updates; measured PhySA cost $0.85/10M steps); the smoothness gain does not carry over to other simulators, even after rescaling the reward weights.

Limitations and Future Work

While the results are promising, the authors note several hurdles:

  • Statistical Significance: While the single-run gains were massive (59.5%), a three-seed replication showed a much smaller, non-significant reduction (7.2%), suggesting high variance in how these policies converge.
  • Short Horizons: The measured episodes were relatively short (~1.9 seconds), meaning the system is currently optimized for early locomotion rather than long-distance walking.
  • Transferability: The smoothness gains did not automatically carry over to the Isaac simulator or the Unitree G1 robot without manual rescaling, highlighting the continued difficulty of "sim-to-sim" transfer.

Future work aims to move beyond global scalar rewards to "clip-level" or "state-conditioned" VLM rewards that can provide more granular feedback during training.

Summary updated

Abstract

Humanoid locomotion policies trained without an explicit smoothness objective tend to produce jerky, high-energy gaits that stress actuators. Vision-language models (VLMs) offer an appealing reward source: given a rendered rollout, a VLM returns an aesthetic quality score on [0,10] without task-specific feature engineering. We find, however, that aesthetic preference and physical smoothness point in opposite directions: across four production VLMs, clips with higher joint acceleration receive higher aesthetic scores (mean Pearson r=+0.66). We study PhySA (Physical Smoothness and Aesthetics), which keeps the two on separate, independently removable reward channels: a sparse, asynchronous VLM score and a phase-triggered correction channel that adjusts physical penalty weights from simulator state. Ablations attribute the smoothness gain to the correction channel. On MuJoCo Humanoid-v5 at 2.6M steps, PhySA lowers joint acceleration by 26 to 32% relative to vanilla PPO, Text2Reward, and Eureka (three seeds), at the cost of shorter episodes. In a single extended run it lowers joint acceleration by 59.5% relative to Prompt2Policy, while a three-seed replication shows a smaller, non-significant reduction (7.2%). The gain does not transfer to IsaacLab or the Unitree G1, even after rescaling the smoothness term.
BibTeX
@misc{fu2026physa,
  author = {Yunwan Fu and Sicheng He and Jiageng Mao and Yue Wang},
  title = {{PhySA: Decoupling Aesthetic and Physical Rewards for Humanoid Locomotion}},
  year = {2026},
  eprint = {2611.07679},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.07679},
}
Figure