NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Performance of the helium dewar and cryocoolers of ASTRO-H SXS

Ryuichi Fujimoto, Yoh Takei, Kazuhisa Mitsuda, Noriko Y. Yamasaki, Masahiro Tsujimoto, Shu Koyama, Kumi Ishikawa, Hiroyuki Sugita, Yoichi Sato, Keisuke Shinozaki, Atsushi Okamoto, Shunji Kitamoto, Akio Hoshino, Kosuke Sato, Yuichiro Ezoe, Yoshitaka Ishisaki, S. Yamada, Hiromi Seta, Takaya Ohashi, Toru Tamagawa, Hirofumi Noda, Makoto Sawada, M. Tashiro, Yoichi Yatsu, Ikuyuki Mitsuishi, Kenichi Kanao, Seiji Yoshida, Mikio Miyaoka, Shoji Tsunematsu, Kiyomi Otsuka, Katsuhiro Narasaki, Michael DiPirro, Peter Shirron, Gary A. Sneiderman, Caroline A. Kilbourne, F. S. Porter, Meng P. Chiao, Megan E. Eckart, Richard L. KelleyProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2016

Abstract

The Soft X-ray Spectrometer (SXS) is a cryogenic high-resolution X-ray spectrometer onboard the ASTRO-H satellite, that achieves energy resolution better than 7 eV at 6 keV, by operating the detector array at 50 mK using an adiabatic demagnetization refrigerator. The cooling chain from room temperature to the ADR heat sink is composed of 2-stage Stirling cryocoolers, a <sup>4</sup>He Joule-Thomson cryocooler, and super uid liquid He, and is installed in a dewar. It is designed to achieve a helium lifetime of more than 3 years with a minimum of 30 liters. The satellite was launched on 2016 February 17, and the SXS worked perfectly in orbit, until March 26 when the satellite lost its function. It was demonstrated that the heat load on the He tank was about 0.7 mW, which would have satisfied the lifetime requirement. This paper describes the design, results of ground performance tests, prelaunch operations, and initial operation and performance in orbit of the flight dewar and cryocoolers.
BibTeX
@inproceedings{fujimoto2016performance,
  author = {Ryuichi Fujimoto and Yoh Takei and Kazuhisa Mitsuda and Noriko Y. Yamasaki and Masahiro Tsujimoto and Shu Koyama and Kumi Ishikawa and Hiroyuki Sugita and Yoichi Sato and Keisuke Shinozaki and Atsushi Okamoto and Shunji Kitamoto and Akio Hoshino and Kosuke Sato and Yuichiro Ezoe and Yoshitaka Ishisaki and S. Yamada and Hiromi Seta and Takaya Ohashi and Toru Tamagawa and Hirofumi Noda and Makoto Sawada and M. Tashiro and Yoichi Yatsu and Ikuyuki Mitsuishi and Kenichi Kanao and Seiji Yoshida and Mikio Miyaoka and Shoji Tsunematsu and Kiyomi Otsuka and Katsuhiro Narasaki and Michael DiPirro and Peter Shirron and Gary A. Sneiderman and Caroline A. Kilbourne and F. S. Porter and Meng P. Chiao and Megan E. Eckart and Richard L. Kelley},
  title = {{Performance of the helium dewar and cryocoolers of ASTRO-H SXS}},
  booktitle = {Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE},
  year = {2016},
  doi = {10.1117/12.2232933},
}

Loading related content...