Percuatenous Liver Biopsy Performed during Inspiration
Abstract
Purpose: Percutaneous liver biopsies have been performed since the late 1800s with several technical modifications. Traditionally, the practice and teaching has been to perform percutaneous biopsies with the breath held at end-expiration to minimize morbidity. This biopsy technique is generally well tolerated when done by experienced operators, with mortality and morbidity rates reported at 0.015 to 0.11% and 2 to 3%, respectively. Contrary to methods described in the literature, we report a potentially safer technique by performing liver biopsies with the breath held at end-inspiration. Methods: On retrospective analysis, a total of 2,670 percutaneous liver biopsies were performed by a single gastroenterologist (S.S.) between the years of 1986 and 2005. The indications were predominantly hepatitis B and C, autoimmune liver disease, alcoholic liver disease, primary biliary cirrhosis, hemochromatosis, and idiopathic liver disease. The age of patients ranged from 21 to 85. The needle insertion site was identified by locating the upper border of the liver using percussion with the breath held in both end-inspiration and end-expiration at the mid-axillary line. Biopsies were performed by using either a Menghini or JamShidi needle under 2% local anesthesia. The biopsy needle was then inserted one or two intercostal spaces below the upper border of the liver at the mid-axillary line. End-inspiration was chosen at the time of biopsy to avoid a sudden inspiratory effort and potential liver displacement caused by pain. An adequate core liver sample was obtained in 98% of patients biopsied. Patients were discharged within a few hours after routine post-biopsy care. Results: Of 2,670 biopsies performed during this time period, our method encountered only two complications (0.07%), significantly lower than previously reported morbidity rates. One patient developed a pneumothorax and the other developed moderate bleeding from a Reidel's lobe requiring 2 units of packed red blood cells. There was no mortality observed. Conclusions: Percutaneous liver biopsy is generally safe, with a low morbidity and mortality rate. In our experience, the above method of performing the biopsy during end-inspiration yielded a lower morbidity rate and no mortality when compared to biopsies done during end-expiration. We therefore conclude that the lower morbidity and mortality observed was a result of fixing the liver at end-inspiration, and consequent liver displacement caused by pain during the biopsy.
BibTeX
@article{ponce2006percuatenous,
author = {Carlos R. Ponce and Urias Cuartas and Sherman Chamberlain and Subbaramiah Sridhar},
title = {{Percuatenous Liver Biopsy Performed during Inspiration}},
journal = {The American Journal of Gastroenterology},
year = {2006},
doi = {10.14309/00000434-200609001-00407},
}Ask Althea to put this paper to the test.
Loading related content...