NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

ORGANIC3D: Grounding 3D CT Vision Language Models in Organ Level Image Text Coupling

Zelong Liu, Hamza Ahmed, Wynn Wingyi Lee, Mickael Torjman, Alexander Dimitrakakis, Jiahua Lu, Timothy Deyer, Bachir Taouli, Zahi A. Fayad, Xueyan MeiarXiv 2026

TL;DR

ORGANIC-3D is a new framework designed to ensure that 3D CT vision-language models (VLMs) ground their medical predictions in actual anatomical evidence rather than linguistic shortcuts. By introducing "controlled anatomical interventions"—such as digitally erasing organs or swapping "left" and "right" in text—the authors achieve state-of-the-art diagnostic accuracy while significantly improving the model's spatial reasoning and clinical reliability.

What Problem Does This Paper Address?

In the world of medical AI, high accuracy can be deceptive. A model might correctly identify a "lung nodule" not because it sees the lesion, but because it recognizes a specific scanner brand's artifacts or knows that certain findings often co-occur. This is known as "shortcut learning."

In 3D Computed Tomography (CT), this lack of grounding is particularly problematic for spatial reasoning. Many existing VLMs struggle with laterality (distinguishing left from right) and often maintain high confidence in a finding even if the relevant organ is digitally removed from the scan. ORGANIC-3D tackles this by moving beyond simple classification metrics to evaluate whether a model is "right for the right reasons."

Methods

The authors introduce two major components: a rigorous evaluation benchmark and a novel model architecture.

The Benchmark: Controlled Anatomical Interventions

To test grounding, the authors developed four "stress tests" for VLMs:

  1. Clinical Finding Independence: Comparing patients matched on all labels except one to see if the model truly detects the unique finding.
  2. Organ Dependence: Digitally "erasing" an organ (filling it with fat/soft tissue density) to see if the model's confidence in a finding within that organ drops.
  3. Laterality: Checking if the model correctly prefers a "right lung" description over a "left lung" description for a right-sided lesion.
  4. Lesion Replacement: Replacing a specific lesion with healthy tissue from the same organ.
The three primary alignment tests used to evaluate model grounding.

The ORGANIC-3D Architecture

The model consists of a 3D Vision Transformer (ViT) encoder and a generative VLM (based on Qwen3.5-4B). Key innovations include:

  • Anatomy Queries & Organ Routing: Instead of global pooling, the model uses 144 learned "anatomy tokens" (e.g., for the liver, left kidney, etc.). When processing a sentence about the kidney, the model "routes" its attention specifically to the kidney tokens.
  • ORGANIC Losses: The model is explicitly trained with an Organ Erasure Loss (forcing scores to drop when the target organ is erased) and a Mirror Loss (enforcing correct left-right orientation).
  • Answer-First Reporting: The generative VLM is trained to list findings before writing the full report narrative, forcing it to commit to specific evidence-based detections first.
Overview of the ORGANIC-3D encoder and VLM architecture.

Datasets

The models were trained exclusively on public data:

  • CT-RATE: 22,757 chest CT scans.
  • Merlin: 15,314 abdominal CT studies.

Evaluation was performed on these plus three external/specialized datasets:

  • RAD-ChestCT: A held-out chest CT dataset for external validation.
  • ReXGroundingCT: Used for lesion-level grounding tests.
  • AbdomenAtlas 3.0: Used for zero-shot tumor detection in the liver, pancreas, and kidneys.

Key Insights and Ideas

  • Accuracy $\neq$ Grounding: The study reveals that top-performing models often fail basic laterality tests. Public encoders reached at most 66% laterality accuracy, essentially only slightly better than a coin flip for "left" vs "right."
  • Mask-Free Grounding at Inference: Remarkably, ORGANIC-3D achieves high organ dependence without needing segmentation masks at test time. The "anatomy queries" learned during training allow the model to internalize anatomical structure.
  • The "Hallucination" Gap: When an organ is erased, most existing VLMs continue to predict findings in that organ up to 31-69% of the time. ORGANIC-3D reduces this "hallucination" rate to nearly zero (retracting 96-99% of findings).

Key Results

  • State-of-the-Art Performance: ORGANIC-3D achieved the highest classification AUROC across all tested public encoders on every test set (CT-RATE, Merlin, and RAD-ChestCT).
  • Spatial Mastery: It reached 77% laterality accuracy, a significant jump over the previous best of 66%.
  • Qualitative Grounding: Occlusion sensitivity maps (Figure 3) show that ORGANIC-3D's predictions are tightly coupled to the actual lesion location, whereas other models often look at unrelated regions like the mediastinum or liver when diagnosing a lung nodule.
Evidence maps showing that ORGANIC-3D focuses on the correct anatomical regions compared to other public models.

Limitations and Future Work

  • Fixed Anatomy: The current model is limited to a fixed set of organ groups defined during training.
  • Report-Derived Labels: The grounding is learned from labels extracted from radiology reports, which may contain their own biases or omissions.
  • Future Directions: The authors aim to extend this framework to open-vocabulary settings (where the model can handle any finding, not just a predefined list) and even finer-grained lesion-level evidence coupling.

Summary updated

Abstract

Vision language models (VLMs) have achieved strong performance in 3D computed tomography (CT) classification, but high accuracy does not reflect whether their predictions rely on the correct anatomical evidence. We introduce ORGANIC3D, a framework for evaluating and improving organ level image text alignment through controlled anatomical interventions. Our benchmark assesses 12 vision encoder checkpoints and 7 generative VLMs using matched patient comparisons, organ erasure, lesion replacement, and laterality perturbations, revealing substantial alignment failures even among top performing models. To learn organ level image text correspondence, ORGANIC3D aligns each finding sentence with the anatomy aware image features and trains on edited scans to anchor this alignment in the organ's image evidence. We further extend this framework to generative VLMs, promoting evidence dependent question answering and report generation. Trained exclusively on public data, ORGANIC3D achieves SOTA classification AUROC on CTRATE, Merlin, and the heldout RADChestCT dataset and reaches 77% laterality accuracy, compared with at most 66% for prior models. Its generative VLM matches or exceeds all evaluated publicly released VLMs on visual question answering, achieves the highest report accuracy, and retracts 96 to 99% of target organ findings after organ removal, versus a maximum of 69% for other models. Together, these results establish ORGANIC3D as a framework for testing whether 3D CT vision language models ground their predictions in anatomical evidence and for improving organ level alignment alongside predictive accuracy.
BibTeX
@misc{liu2026organic,
  author = {Zelong Liu and Hamza Ahmed and Wynn Wingyi Lee and Mickael Torjman and Alexander Dimitrakakis and Jiahua Lu and Timothy Deyer and Bachir Taouli and Zahi A. Fayad and Xueyan Mei},
  title = {{ORGANIC3D: Grounding 3D CT Vision Language Models in Organ Level Image Text Coupling}},
  year = {2026},
  eprint = {2611.23529},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.23529},
}

Loading related content...