Optimizing Winter Air Quality in Pig-Fattening Houses: A Plasma Deodorization Approach

Liping Zhang, Meng Zhang, Qianfeng Yu, Shiguang Su, Yan Wang, Yu Fang, Wei Dong2024 · DOI

TL;DR

This study investigates the effectiveness of a novel plasma deodorization system in improving winter air quality within pig-fattening houses. By employing alternating internal and external circulation modes, the system significantly reduced harmful gases like NH3 and H2S, while also offering a more efficient approach to CO2 management compared to traditional ventilation.

What Problem Does This Paper Address?

Large-scale pig farming, while efficient, presents significant challenges in maintaining optimal air quality within animal housing. High concentrations of gases like ammonia (NH3), hydrogen sulfide (H2S), and carbon dioxide (CO2), along with dust and microbial content, negatively impact pig health, production performance, and can even pose risks to farm workers and the surrounding environment. Traditional methods for odor and gas control, such as water washing or activated carbon adsorption, often suffer from low efficiency, high labor intensity, and can be costly. This paper addresses the need for a more effective, automated, and less labor-intensive solution for managing indoor air quality in pig-fattening houses, particularly during winter when ventilation is critical but can lead to significant heat loss.

Methods

The core of this research lies in the evaluation of a plasma deodorization unit integrated with a ventilation system. The system utilizes a combination of dielectric barrier discharge (DBD) plasma and microwave photolysis technology. The experimental setup involved two pig-fattening houses: one equipped with the plasma deodorizer operating in two distinct modes (internal circulation - IC-mode, and external circulation - EC-mode) and a control house with natural ventilation.

  • Plasma Deodorization Unit: This unit comprises four main components: a primary filter plate (for dust removal and dehumidification), a DBD plasma generator, a microwave photolysis module, and an ozone removal module. This multi-stage approach aims to break down various pollutants.
  • Ventilation System: The system is designed to manage airflow.
  • Internal Circulation (IC-mode): All windows are sealed, and air is drawn into the deodorizer and then recirculated back into the house. This mode aims to maximize treatment efficiency by keeping the air within the confined space.
  • External Circulation (EC-mode): Windows are opened, and treated air is expelled into the atmosphere. This mode facilitates greater air exchange with the outside.
  • Monitoring: A comprehensive IoT-based system was employed for real-time monitoring of temperature, relative humidity, NH3, H2S, and CO2 concentrations. Data was collected hourly over a 60-day period.

Datasets

The study utilized data collected from two pig-fattening houses over a 60-day period (November 1, 2022, to December 30, 2022). House 1 served as the experimental group with the plasma deodorization system (IC and EC modes), while House 2 acted as the control group with natural ventilation. The data collected included hourly measurements of temperature, relative humidity, NH3, H2S, and CO2.

Key Insights and Ideas

  • Dual-Mode Effectiveness: The plasma deodorization system demonstrated significant effectiveness in both internal and external circulation modes, but with different strengths. The IC-mode excelled at removing NH3 and H2S, while the EC-mode was more effective at reducing CO2.
  • Synergistic Gas Removal: The combination of DBD plasma and microwave photolysis proved highly effective in disintegrating harmful gases like NH3 and H2S into less harmful substances.
  • Ozone Management: The inclusion of an ozone removal module was crucial to ensure that the generated ozone levels remained within safe limits for both pigs and farm workers.
  • Winter Air Quality Optimization: The ability to switch between IC and EC modes offers a flexible strategy for optimizing winter air quality, balancing gas purification with temperature and humidity control.
  • Beyond Traditional Methods: The plasma approach offers a more automated and potentially less labor-intensive alternative to traditional gas and odor control methods.

Key Results

  • NH3 and H2S Reduction: The IC-mode achieved a remarkable reduction of 63.87% in NH3 and nearly 100% (not detected) in H2S compared to the control house. The EC-mode also showed significant reductions of 17.1% for NH3 and 28.57% for H2S.
  • CO2 Dilution: The EC-mode resulted in a 16.43% decrease in CO2 concentration compared to the control house, while the IC-mode showed a slight increase of 7.01%.
  • Temperature and Humidity: The IC-mode maintained higher indoor temperatures and relative humidity, beneficial for winter conditions, while the EC-mode led to lower levels due to increased air exchange.
  • Animal Performance: The study observed no adverse effects on pig health or survival rates, with survival rates of 97% and 98.5% in House 1 and House 2, respectively. The air purification effect of the system surpassed natural ventilation.
  • Ozone Levels: All measured ozone levels remained within the safe range as per GB/T1883-2002 standards.

Limitations and Future Work

  • Spatial Requirement and Cost: The authors acknowledge that the current apparatus has an extensive spatial requirement and elevated expenditures, limiting its widespread adoption.
  • Dust Accumulation: The harsh environment within pig houses led to dust accumulation on the purification apparatus and sensors, potentially compromising their operational efficacy and requiring regular manual upkeep.
  • Future Research Directions: The authors plan to focus on miniaturization of the system, augmenting its efficiency, and reducing costs. They also aim to conduct trials in a more diverse range of environments to validate the system's resilience. The paper suggests that a hybrid approach, using internal circulation for gas purification and periodic external circulation for CO2 and ozone expulsion, might be the optimal operational mode.

Summary updated

BibTeX