Optimizing Water Droplet Diameter of Spray Cooling for Dairy Cow in Summer Based on Enthalpy Difference Theory

Tao Ding, Baoxi Sun, Zhengxiang Shi, Baoming LiEnergies 2019

TL;DR

This paper investigates the optimal average droplet diameter (ADSD) for spray cooling systems to effectively alleviate heat stress in dairy cows during summer. By combining theoretical analysis with laboratory and field experiments, the study identifies a sweet spot for ADSD that maximizes heat exchange and cooling efficiency while minimizing water consumption.

What Problem Does This Paper Address?

Dairy cows are highly susceptible to heat stress during hot and humid summer months, leading to reduced feed intake, increased illness, and decreased milk yield. Spray cooling is a common method to mitigate this, but its effectiveness is significantly influenced by the size of the water droplets. Previous research has explored various aspects of spray cooling, but a clear understanding of how the average droplet diameter (ADSD) impacts heat exchange and overall cooling performance, while also considering practical factors like water usage, has been lacking. This paper aims to fill that gap by systematically determining the optimal ADSD for efficient and economical dairy cow cooling.

Methods

The researchers employed a multi-pronged approach:

  • Theoretical Analysis: They utilized the enthalpy difference theory to model the heat and mass transfer processes occurring during spray cooling. This theory considers both sensible heat exchange (due to temperature differences) and latent heat exchange (due to water evaporation).
  • Laboratory Experimentation: A simulated dairy cow was used on a test bench to replicate summer environmental conditions. They controlled temperature and humidity and used six different nozzles under various pressures to generate eighteen distinct ADSDs. Heat exchange was calculated for each condition.
  • Field Experimentation: The optimized ADSDs identified in the lab were then tested in a real dairy farm setting. They monitored physiological indicators of dairy cows, including body temperature (using infrared thermography), rectal temperature, and respiratory rate. Heat exchange was also calculated in the field.
  • Instrumentation: Key instruments included a laser precipitation monitor (LPM) for measuring ADSD, thermocouples and humidity sensors for environmental monitoring, and infrared thermal imagers and electronic thermometers for physiological measurements.

Datasets

Not discussed in the paper. The study generated its own experimental data through laboratory and field tests.

Key Insights and Ideas

  • The "Sweet Spot" for Droplet Size: The study reveals that there isn't a simple "smaller is better" or "larger is better" rule for droplet size. Instead, there's an optimal range for ADSD that maximizes heat exchange. Droplets that are too small might evaporate too quickly before effectively cooling, while droplets that are too large might not form a sufficient water film or could lead to excessive water runoff and waste.
  • Enthalpy Difference Theory as a Predictive Tool: The theoretical framework based on enthalpy differences proved effective in predicting heat exchange and guiding the optimization process, bridging the gap between lab simulations and real-world application.
  • Nozzle Selection Matters: The specific nozzle models (9080 and 90100) were identified as crucial for achieving the optimal ADSDs in the laboratory setting.
  • Water Savings are Significant: Optimizing ADSD not only improves cooling but also leads to substantial reductions in water consumption, a critical factor for sustainable dairy farming.

Key Results

  • Laboratory Findings: Maximum heat exchange was observed within an ADSD range of 0.914–0.995 mm. Specifically, ADSDs of 0.914 mm and 0.995 mm yielded peak heat exchange under different wind speed conditions. Nozzles 9080 and 90100 were associated with these optimal ranges.
  • Field Experiment Findings: The best cooling effect in the field was achieved with an ADSD of 0.947 mm. This resulted in a 22.86% reduction in water consumption compared to a larger ADSD (1.127 mm).
  • Physiological Improvements: The optimal ADSD of 0.947 mm led to a more significant reduction in respiratory rate compared to a larger droplet size (1.127 mm). While rectal temperatures remained within normal ranges, the study indicated that the chosen ADSD had a better effect on reducing respiratory rate.

Limitations and Future Work

  • Environmental Conditions: The study focused on specific temperature and humidity combinations. Further research could explore a wider range of environmental conditions to generalize the findings.
  • Cow Breed and Age: The experiments were conducted on dairy cows, likely of a specific breed (implied Holstein). Future work could investigate if the optimal ADSD varies for different breeds or age groups of cattle.
  • Long-Term Effects: While the study assessed immediate cooling effects, longer-term impacts on milk production and overall herd health could be a valuable area for future investigation.
  • Wastewater Management: The paper mentions increased sewage generation with larger droplets. Further research could explore integrated solutions for wastewater management in conjunction with optimized spray cooling.

Summary updated

Abstract

Spray cooling is widely used in relieving heat stress in dairy cows during summer, in which the cooling effect is highly correlated to the diameter of water droplet. To optimize the average diameter of spraying droplet (ADSD) in the process of heat transfer, a theoretical analysis was performed based on the enthalpy difference theory in this study. A platform was built to simulate the processes of spray cooling and its heat stress alleviation to dairy cows in field, and a field experiment was applied to verify the diameter of water droplets suitable for spray cooling. Heat exchange was calculated for eighteen different ADSD in three different environment conditions in the laboratory. The spraying droplets with eighteen diameters were formed by using six different nozzles under the combinations of three pressures and two wind speeds conditions, which were controlled by heaters. The relationship between the ADSD and heat exchange was established with the purpose to determine the appropriate diameter for practical production. In the field test, body temperature, rectal temperature, and respiratory rate of dairy cows were monitored, and the heat exchange was analyzed to verify the optimal diameter spraying cooling in summer. Results showed that the heat exchange generally increased as ADSD increased, and maximum heat exchanges were reached when the ADSD was averaged at 0.914 mm and 0.995 mm, under which the models of the corresponding nozzles were 9080 and 9010, respectively. After that, the heat exchange decreased as the ADSD continued to increase. Field experiment indicated that the best cooling effect could be achieved with the ADSD of 0.947 mm, and the water consumption for spray cooling was reduced by 22.8% under the scenario.
BibTeX
@inproceedings{ding2019optimizing,
  author = {Tao Ding and Baoxi Sun and Zhengxiang Shi and Baoming Li},
  title = {{Optimizing Water Droplet Diameter of Spray Cooling for Dairy Cow in Summer Based on Enthalpy Difference Theory}},
  booktitle = {Energies},
  year = {2019},
  doi = {10.3390/en12193637},
}
Figure