Optimization study of scintillator shape of electromagnetic calorimeter for Higgs factories

Takanori Mogi, T. Tanabe, W. Ootani, Satoru Yamashita, Ryousuke Shirai, T. Takeshita, Y. Niu, Jianbei LiuarXiv 2020 · DOI

Abstract

Scintillator-based calorimeters for experiments at Higgs factories (e.g. ILC) demand scintillator designs that can detect sufficient number of photons and have good light yield uniformity, and that they can be easily mass-produced. In order to meet these requirements, scintillator strips with a small dimple has been proposed. In our study, we measure the light yield of a dimple scintillator sample; we then compare the measurements with light tracing simulation using GEANT4. We intend to use our results to propose an optimized scintillator shape.

Introduction

Future "Higgs factories," such as the International Linear Collider (ILC), require electromagnetic calorimeters (ECAL) with unprecedented energy resolution to study the Higgs boson and search for new physics. To achieve this, scientists use Particle Flow Algorithms (PFA) that demand high-granularity detectors. A Scintillator-based ECAL (ScECAL) typically uses long, thin scintillator strips (5 mm × 45 mm × 2 mm) to reduce the number of expensive readout channels by 90% compared to square tiles.

However, these strips face a significant challenge in balancing light yield and uniformity. Side-readout methods offer high light yield but poor spatial uniformity, while bottom-readout methods provide excellent uniformity but insufficient light yield for reliable particle detection. This study investigates the dimple readout—where a small cavity is carved into the center of the strip to house a Silicon Photomultiplier (SiPM)—as a potential solution to balance these competing needs.

The Dimple Readout Design

The proposed design involves embedding the SiPM directly into a central indentation in the scintillator material. This geometry is intended to maximize the collection of scintillation photons while maintaining a consistent response regardless of where a particle strikes the strip.

A BC-408 plastic scintillator strip featuring a central dimple for SiPM integration.

Methodology

The study combined experimental hardware measurements with high-fidelity software simulations:

  1. Experimental Setup: A BC-408 plastic scintillator strip with a central dimple was tested using a Hamamatsu SiPM. A Strontium-90 ($^{90}$Sr) source provided beta rays to simulate incident particles. By scanning the source across the strip's 45 mm length, the team measured the position-dependent light yield.
  2. Simulation: A photon-tracing simulation was developed using GEANT4 (specifically the G4OpticalPhoton library). This allowed for the modeling of individual photons as they reflected off the strip's surfaces or were absorbed by the surrounding Enhanced Specular Reflector (ESR) film.
  3. Parameter Tuning: Optical properties, such as bulk light attenuation length and surface reflectivity, were tuned in the simulation to match the physical measurements, providing a validated model for future optimization.

Key Results and Validation

The dimple readout produced a mean light yield of approximately 21 photoelectrons (p.e.), which is roughly twice the yield of conventional bottom-readout methods. Furthermore, the design maintained high uniformity across the length of the strip, meeting the requirements for the Strip Splitting Algorithm (SSA) used in PFA.

Comparison between experimental measurements and GEANT4 simulations of photon counts vs. position across the scintillator strip.

By tuning the simulation parameters—specifically setting the reflectivity to 95% and the absorption length to 200 cm—the GEANT4 model successfully reproduced the experimental results. An observed "dip" in light yield at the center of the strip was identified not as a design flaw, but as an artifact of the beta ray spread after passing through the experimental collimator.

Discussion and Future Work

The simulation highlighted the extreme sensitivity of light yield to material properties; a mere 1% change in wrapping reflectivity can reduce the detected signal by half. This underscores the need for precise, wavelength-dependent material characterization.

While this work validates the dimple readout and the simulation framework, the final optimization of the scintillator shape (e.g., exact dimple curvature) and the industrial feasibility of mass-producing thousands of precision-carved strips remain subjects for future investigation.

Summary updated

Abstract

Scintillator-based calorimeters for experiments at Higgs factories (e.g. ILC) demand scintillator designs that can detect sufficient number of photons and have good light yield uniformity, and that they can be easily mass-produced. In order to meet these requirements, scintillator strips with a small dimple has been proposed. In our study, we measure the light yield of a dimple scintillator sample; we then compare the measurements with light tracing simulation using GEANT4. We intend to use our results to propose an optimized scintillator shape.
BibTeX
@misc{mogi2020optimization,
  author = {Takanori Mogi and T. Tanabe and W. Ootani and Satoru Yamashita and Ryousuke Shirai and T. Takeshita and Y. Niu and Jianbei Liu},
  title = {{Optimization study of scintillator shape of electromagnetic calorimeter for Higgs factories}},
  year = {2020},
  eprint = {2002.06415},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2002.06415},
}
Figure