Optimization of Stripping Voltammetric Sensor by a Back Propagation Artificial Neural Network for the Accurate Determination of Pb(II) in the Presence of Cd(II)

Guo Zhao, Hui Wang, Gang Liu, Zhiqiang Wang2016

TL;DR

This paper presents a novel approach to accurately detect lead (Pb(II)) in the presence of cadmium (Cd(II)) using square wave anodic stripping voltammetry (SWASV) combined with a back propagation artificial neural network (BP-ANN). By leveraging the BP-ANN to model the complex, non-linear interactions between Pb(II) and Cd(II) signals, the method significantly improves prediction accuracy compared to traditional direct calibration models, making it a promising tool for environmental monitoring.

What Problem Does This Paper Address?

Lead (Pb(II)) is a highly toxic heavy metal that poses significant environmental and health risks, even at very low concentrations. Accurate and sensitive detection of lead, particularly in complex matrices like soil, is crucial for environmental risk assessment and public health. Anodic stripping voltammetry (ASV) is a sensitive electrochemical technique for trace metal detection. However, a major challenge in ASV, especially when determining Pb(II), is the interference from other co-existing heavy metal ions, such as cadmium (Cd(II)). These interfering ions can alter the stripping peak currents of Pb(II), leading to reduced accuracy and precision in direct calibration models. While chemically modified electrodes (CMEs) can enhance electrode performance, they often involve complex procedures and expensive materials. This paper aims to address the interference issue by developing a more robust and accurate method for Pb(II) determination in the presence of Cd(II) without requiring complex electrode modifications, utilizing a bismuth film electrode (Bi/GCE) and an advanced data analysis technique.

Methods

The core of this work lies in the synergistic combination of square wave anodic stripping voltammetry (SWASV) with a bismuth film electrode (Bi/GCE) and a back propagation artificial neural network (BP-ANN).

  • SWASV with Bi/GCE: A bismuth film is electrodeposited onto a glassy carbon electrode (GCE) to create a Bi/GCE. This Bi/GCE is used as the working electrode for SWASV. Bismuth is chosen for its low toxicity, ability to form alloys with heavy metals, and ease of preparation, which helps in preconcentrating and detecting Pb(II) efficiently. The SWASV technique involves electroplating the metal ions onto the electrode surface and then stripping them off, generating a current proportional to the metal concentration.
  • BP-ANN for Data Analysis: A three-layer BP-ANN (input, hidden, output) is employed to model the non-linear relationship between the SWASV signals and the concentrations of Pb(II) and Cd(II).
  • Inputs: The stripping peak currents of Pb(II) and Cd(II) from the SWASV measurements.
  • Output: The predicted concentration of Pb(II).
  • Optimization: The BP-ANN model's parameters, including the number of hidden neurons, transfer functions, and training functions, were optimized to achieve the best prediction accuracy. Data normalization was performed to improve network convergence.

This approach moves beyond simple linear calibration by using the BP-ANN to learn and account for the complex interference effects of Cd(II) on the Pb(II) signal.

Datasets

The study utilized experimental data generated from SWASV measurements.

  • Training Dataset: 37 sets of experimental data were used to train the BP-ANN model.
  • Testing Dataset: 12 sets of experimental data were used to validate the prediction accuracy of the trained BP-ANN model.
  • Real Samples: Soil samples were collected and extracted for analysis to demonstrate the method's applicability to real-world scenarios.

The paper does not introduce new benchmark datasets but rather uses experimentally derived data for model training and evaluation.

Key Insights and Ideas

  • Cd(II) Interference is Non-Linear and Significant: The study clearly demonstrates that Cd(II) significantly impacts Pb(II) stripping currents, and this interference is not a simple linear relationship. The effect is most pronounced at low Cd(II) concentrations (around 5 µg/L). This highlights the inadequacy of simple linear models when dealing with such interferences.
  • BP-ANN Excels at Non-Linear Modeling: The BP-ANN proved highly effective in capturing the complex, non-linear interactions between the Pb(II) and Cd(II) signals and the Pb(II) concentration. This ability to learn intricate relationships is key to its superior performance over linear regression.
  • Bi/GCE as a Robust Platform: The bismuth film electrode (Bi/GCE) provided a stable and reproducible platform for SWASV, essential for generating reliable data for the ANN model. Its ease of preparation and low toxicity make it an attractive choice.
  • Integrated Approach for Enhanced Accuracy: The combination of a sensitive electrochemical technique (SWASV) with an advanced machine learning model (BP-ANN) offers a powerful strategy for overcoming analytical challenges in complex samples.

Key Results

  • Improved Prediction Accuracy: The BP-ANN model demonstrated significantly higher prediction accuracy for Pb(II) compared to the direct calibration model.
  • MAE: 1.52 µg/L for BP-ANN vs. 12.56 µg/L for direct calibration.
  • RMSE: 1.69 µg/L for BP-ANN vs. 14.6 µg/L for direct calibration.
  • ARE: 28.88% for BP-ANN vs. 117.61% for direct calibration.
  • R²: 0.998 for BP-ANN vs. 0.952 for direct calibration (in linear regression analysis of prediction results).
  • Real Sample Validation: The method was successfully applied to soil samples, achieving an average recovery of 98.42%, confirming its practical applicability and reliability.
  • Reproducibility: The Bi/GCE showed good reproducibility with relative standard deviations (RSDs) of 2.677% for Cd(II) and 2.281% for Pb(II) in repeated measurements. The proposed method also exhibited good repeatability for real sample analysis with an RSD of 3.8%.

Limitations and Future Work

  • Limitations of Direct Calibration: The study clearly shows that direct linear calibration models are insufficient for accurate Pb(II) determination in the presence of varying Cd(II) concentrations due to complex interference.
  • ANN Model Complexity: While the BP-ANN offers superior accuracy, it requires careful optimization of parameters (e.g., number of hidden neurons) and a sufficient amount of training data. The paper selected 14 neurons in the hidden layer, balancing complexity and efficiency.
  • Future Work: The authors suggest that this integrated approach of ASV and machine learning algorithms (like ANNs) can be extended to accurately estimate other heavy metals and can be applied in various fields such as environmental control, food safety supervision, and other analytical applications. The potential for developing more sophisticated ANN architectures or exploring other machine learning techniques for even higher accuracy and broader applicability is implied.

Summary updated

BibTeX
@misc{zhao2016optimization,
  author = {Guo Zhao and Hui Wang and Gang Liu and Zhiqiang Wang},
  title = {{Optimization of Stripping Voltammetric Sensor by a Back Propagation Artificial Neural Network for the Accurate Determination of Pb(II) in the Presence of Cd(II)}},
  year = {2016},
  doi = {10.3390/s16091540},
}