Abstract
Intereye differences of 5μm for retinal nerve fiber layer and 4μm for macular ganglion cell + inner plexiform layer are robust thresholds for identifying unilateral optic nerve lesions. These thresholds may be useful in establishing the presence of asymptomatic and symptomatic optic nerve lesions in multiple sclerosis and could be useful in a new version of the diagnostic criteria. Our findings lend further validation for utilizing the visual system in a multiple sclerosis clinical trial setting. Ann Neurol 2019;85:618-629.
BibTeX
@article{nolankenney2019optimal,
author = {Rachel Nolan-Kenney and Mengling Liu and Omar Akhand and Peter A. Calabresi and Friedemann Paul and Axel Petzold and Lisanne J. Balk and Alexander U. Brandt and Elena H. Martínez‐Lapiscina and Shiv Saidha and Pablo Villoslada and Abdullah Abu Al‐Hassan and Raed Behbehani and Elliot M. Frohman and Teresa C. Frohman and Joachim Havla and Bernhard Hemmer and Hong Jiang and Benjamin Knier and Thomas Korn and Letizia Leocani and Athina Papadopoulou and Marco Pisa and Hanna Zimmermann and Steven Galetta and Laura J. Balcer},
title = {{Optimal intereye difference thresholds by optical coherence tomography in multiple sclerosis: An international study}},
journal = {Annals},
year = {2019},
doi = {10.1002/ana.25462},