OP05.05: Comparison of 2‐dimensional to 3‐dimensional saline infusion sonohysterograms for the evaluation of intrauterine pathology

Stephanie Terry, Erika Banks, Kenneth D. Harris, P. DarUltrasound 2008 · DOI

Abstract

To compare sensitivity and specificity of 3-dimensional saline infusion sonohysterogram (3DSIS) to 2-dimensional sonohysterogram (2DSIS) using hysteroscopy and histological diagnosis as the gold standard. A retrospective analysis of 804 patients that had a SIS between July 1st 2005 and April 30th 2007 in our gynecological ultrasound unit. SIS's were arbitrarily performed through 2-dimensional or 3-dimensional approach using Voluson 730 (GE, Milwaukee, WI) and HDI-5000 (ATL, Philips, Germany) by 2 experienced sonologists. Management decisions and operative procedures were performed by the referring provider according to clinical indications. Patients that had diagnostic hysteroscopy and complete histological evaluation, either through polypectomy, myomectomy, curettage or hysterectomy, were included in the study. Patients without operative or histological reports were excluded. Student t and chi square tests were used for statistical analysis. P < 0.05 was considered statistically significant. Out of 804 patients that had SIS, 125 patients met our inclusion criteria. One patient was excluded for incomplete operative description. Patient median age was 48 (range 19–82). Seventy seven patients were premenopausal and 48 patients were postmenopausal. Forty three patients had 2DSIS and 82 patients had 3DSIS. 3DSIS was found to correlate with hysteroscopic findings more often than 2DSIS (P < 0.02). A trend for higher specificity of 3DSIS was seen for polyps, myomas, hyperplasia and normal tissue, but it did not reach statistical significance. No difference in sensitivity of 3DSIS as compared to 2DSIS was found for all pathological diagnoses. 3DSIS correlates better than 2DSIS with hysteroscopy but does not offer improved detection rate of histological diagnosis. Higher specificity of the 3DSIS when compared to the 2DSIS for histological diagnosis is possible but larger scale studies are needed to explore this finding.
BibTeX
@inproceedings{terry2008op,
  author = {Stephanie Terry and Erika Banks and Kenneth D. Harris and P. Dar},
  title = {{OP05.05: Comparison of 2‐dimensional to 3‐dimensional saline infusion sonohysterograms for the evaluation of intrauterine pathology}},
  booktitle = {Ultrasound},
  year = {2008},
  doi = {10.1002/uog.5662},
}

Loading related content...

Figure