Online Bayesian Recalibration of Brain–Computer Interfaces with Language Model Potentials

Noah Cowan, Scott LindermanNeurIPS 2026

TL;DR

Brain–computer interfaces (BCIs) lose accuracy over time as recorded neural signals naturally drift, and constantly asking users to read calibration scripts is exhausting. Existing systems use language models (LMs) to guess what the user meant and retrain the decoder on the fly, but blindly trusting a single LM guess can cause errors to snowball. By reframing this self-calibration as online Bayesian filtering, the authors introduce B-CORP, a method that embraces uncertainty across multiple LM guesses and tracks how parameters drift over time, keeping BCIs reliable without frustrating recalibration sessions.

What Problem Does This Paper Address?

Imagine typing on a keyboard where the keys slowly shuffle themselves every few hours. That is the reality of intracortical BCIs. Microelectrode arrays implanted in the brain sample slightly different neurons over hours, days, and weeks. Without periodic recalibration, a neural decoder's ability to translate brain activity into text or speech degrades rapidly.

Collecting fresh, labeled calibration data means forcing paralyzed users to mentally recite scripted sentences—a tedious tax on their time and cognitive energy. The current state-of-the-art workaround, CORP (Continual Online Recalibration with Pseudo-labels), recalibrates without true labels. As a user communicates freely, CORP pairs the neural decoder with an LM, takes the single highest-scoring sentence hypothesis, treats it as absolute ground truth (a "hard pseudo-label"), and fine-tunes the decoder via gradient descent.

The catch? Overconfidence. If the neural signal has drifted significantly or the LM makes a bad guess, CORP still forces the decoder to learn that mistake with 100% certainty. Errors compound, and the BCI can spiral into a self-reinforcing cycle of gibberish.

Methods

The authors realize that CORP is quietly—and crudely—trying to do online Bayesian filtering. They cast the decoder's parameters as hidden states evolving over time, and treat the LM not as an oracle of truth, but as an observation model providing "language model potentials" (probabilistic nudges toward plausible English).

Viewing CORP through this Bayesian lens exposes three harsh approximations: taking a single hard label, doing only one update pass, and ignoring how parameters drift between sessions. To relax these, the authors build B-CORP using three drop-in upgrades:

Figure 1: B-CORP: Sustainable BCIs The data are in yellow, the standard CORP procedure is marked in orange and the B-CORP additions are in light blue. For B-CORP, we add in dynamics between the past session parameters and the next parameters, do multiple iterations of parameter recalibration, and do top-K marginalization instead of placing all mass on one output as ˆy.
  1. Soft Top-$K$ Marginalization: Instead of betting everything on the LM's #1 guess (e.g., "trains whistling"), B-CORP keeps the top $K$ candidates (like "that's whistling" and "this whistling") weighted by their probabilities. If the LM is uncertain, the gradient update hedges its bets.
  2. Iterated Coordinate Refinement: Standard CORP generates candidates once and updates parameters once. B-CORP loops this a few times per sentence: update the decoder slightly, re-evaluate what the neural signals look like under the freshly updated decoder to refresh the candidate list, and update again (with loss-based safeguards against overfitting).
  3. Structured Dynamics Prior: Decoders typically use a per-session affine input layer to align daily neural shifts. B-CORP learns a low-rank (rank-8) subspace of how this layer's parameters moved in past sessions, extrapolating velocity across calendar gaps to give new sessions a smart starting point and regularizer.

Datasets

The authors test B-CORP on two controlled synthetic benchmarks and two retrospective real-world human BCI datasets:

  • Synthetic Benchmarks: A drifting linear-Gaussian state-space model and a synthetic sequence decoder with low-rank input drift, built to isolate how each algorithmic piece behaves when true drift is known.
  • Willett 2021 Handwriting BCI Dataset (CORP split): Intracortical recordings of free-writing across 10 sessions (377 sentences spanning five months), using LM-rescored beams corrected by Claude Sonnet 4.6 (and an open-weight Qwen2.5-72B variant).
  • Willett 2023 Speech BCI Dataset: A substantially harder, faster-timescale intracortical speech decoding dataset evaluated on unseen days following 20 training days.

Key Insights and Ideas

  • Pseudo-labeling is secret Bayesian filtering: Connecting test-time self-supervision to state-space filtering gives researchers a principled mathematical knob to turn whenever using black-box priors (like LLMs) to supervise drifting sensors.
  • More gradient steps hurt naive pseudo-labeling: When the authors forced standard CORP to take the same number of gradient steps as B-CORP on the harder Speech BCI task, CORP's word error rate exploded to 42.29% because it aggressively memorized its own mistakes. Soft labels and guarded coordinate ascent prevent this death spiral.
  • Real neural drift is messier than linear subspaces: While the low-rank dynamics prior drove massive gains in synthetic tests, its direct accuracy boost on real BCI data was modest—Instead, its real superpower in human data was reducing variance and preventing jarring error spikes at the start of new sessions.

Key Results

Across the board, B-CORP improves both accuracy and stability:

  • Synthetic Validation: In the drifting Gaussian setup, B-CORP closes 58% of the MSE gap between CORP and an oracle Kalman filter. In the synthetic sequence decoder, all three components stack cleanly, dropping token error from 22.5% (CORP) down to 10.4% (Full B-CORP), nearly matching the 9.9% oracle.
Figure 3: Synthetic sequence decoder. Single-component ablations over top-3 confidence labels, coordinate refinement, and time-aware low-rank dynamics show that all three pieces contribute. Aggregate token error falls from CORP 22.5% to top-3 17.8%, coordinate-only 16.9%, dynamics- only 13.5%, and full B-CORP 10.4%; the oracle (uses the true sessions-specific decoder state) is 9.9%.
  • Handwriting BCI: B-CORP lowers Word Error Rate (WER) from 4.07% (matched CORP baseline) to 2.71%—a 33% relative reduction—with noticeably tighter confidence intervals and smoother session starts.
  • Speech BCI: Where signals are noisier, B-CORP achieves 21.30% WER, beating no-adaptation by 3.50 percentage points and CORP by 3.06 percentage points.

Limitations and Future Work

  • Retrospective & Single-Participant: All real-BCI tests were offline replays from single participants. Real-time, closed-loop testing is needed to see how B-CORP's extra compute iterations affect latency and how human users co-adapt when the decoder shifts beneath them.
  • Unmodeled Drift Geometry: Real neural drift over months is likely nonlinear, abrupt, or higher-rank than a simple rank-8 fixed-velocity model captures.
  • Prior Vulnerability: If a user tries to say something wildly out-of-distribution where the LM prior is dead wrong across all top-$K$ candidates, B-CORP can still adapt in the wrong direction. Extending this framework beyond language (e.g., robotic arm control) will require inventing non-linguistic task priors.

Summary updated

Abstract

Brain–computer interfaces (BCIs) must continually adapt as neural signals drift, yet labeled calibration data is expensive to collect at time of use. Recent systems address this challenge by updating neural decoders using language-model–pseudo-labels, but they treat the pseudo-label as ground truth. We reinterpret recalibration as approximate Bayesian filtering: the decoder parameters are the latent states, and language models provide observations in the form of unnormalized potentials. Guided by this analysis, we introduce \textbf{B-CORP} (Bayesian Continual Online Recalibration with Pseudo-labels). B-CORP replaces hard pseudo-labels with a soft top-$K$ marginalization, increases the number of iterations in the coordinate ascent on the joint likelihood, and models parameter drift with a prior on latent dynamics. Across synthetic drifting regression tasks and real BCI benchmarks, including handwriting and speech BCI datasets, B-CORP attains word error rates consistently under 3\% on a difficult handwriting BCI dataset. B-CORP improves almost 30\% versus the state-of-the-art, while retaining performance even with poor pseudo-labels where naive methods fail. More broadly, our approach connects pseudo-label recalibration with online Bayesian inference, providing a principled foundation for problems requiring long-term recalibration with access to black box predictive models, such as LLMs, for use as strong priors over the labels.
BibTeX
@inproceedings{cowan2026online,
  author = {Noah Cowan and Scott Linderman},
  title = {{Online Bayesian Recalibration of Brain–Computer Interfaces with Language Model Potentials}},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2026},
  url = {https://openreview.net/forum?id=dg1ZRMGStk},
}
Figure