One, No One and One Hundred Thousand CTs: Testing Anatomical Control in Text-to-CT Generation

Francesca Pia Panaccione, Eugenio Lomurno, Matteo MatteucciarXiv 2026

TL;DR

Generative AI models can now synthesize 3D chest CT scans from written radiology reports, promising infinite medical data for rare conditions—assuming the models actually listen to what you type. By introducing a behavioral testing toolkit called CtrlCT, the authors discover a surprising tradeoff: the models that produce the most realistic-looking scans largely ignore targeted edits to the text, while the models that actually obey instructions generate less realistic, less diverse anatomy.

What Problem Does This Paper Address?

Suppose you want to train a medical classifier on rare combinations of lung and heart conditions. Instead of waiting years to scan real patients, you can take an existing radiology report, tweak a single sentence—say, changing "no pleural effusion" to "bilateral pleural effusion" (fluid around the lungs)—and feed it to a Text-to-CT generator.

There is just one catch: nobody systematically checks if changing one sentence actually changes that specific anatomy in the generated 3D volume. Standard evaluations score batches of synthetic CTs from unedited reports on overall population realism (like Fréchet Distance) and broad report agreement. Because an edited report describes a hypothetical patient who was never scanned, there is no "ground truth" reference CT to compare against. Furthermore, every published generator uses different preprocessing and custom baselines, creating an illusion of control without fair comparisons.

Methods

To test anatomical control without a reference CT, the authors build CtrlCT, a standardized toolkit built around metamorphic testing—evaluating a system by checking how controlled changes to its input transform its output.

Figure 1: CtrlCT edits one finding of a real report and checks whether the CT follows. The generator synthesises the CT of the report and of its edit at the same seed, here at two seeds (red: effusion; blue: heart; TotalSegmentator [46]). Right: its CtrlCT Report Card over all cases and seeds (Tab. 2): its main measures between their null control and real or ideal value, and the diagnostic rules that are triggered.

First, Pre-Flight Checks harmonize generated 3D volumes (fixing orientation flips, voxel spacing, and flagging edits truncated by short text-encoder token windows). Next, CtrlCT evaluates two distinct families of properties using automatic deep-learning segmenters (TotalSegmentator) and classifiers (NV-Reason-CT):

  1. Credibility (Population-level): Evaluates CTs from unedited reports. Alongside standard Realism (Fréchet Distance), Diversity (coverage), Report Agreement (AUROC), and Downstream Utility (training classifiers on synthetic data to test on real data), the authors add Report Use—measuring how much a CT changes at a fixed random seed when the report's words are scrambled or replaced with off-topic, non-medical text.
  2. Control (Case-level, Fixed Seed): Compares the CT of an original report against its single-finding edit at the exact same random seed across three criteria:
  3. Target Response (C1): Does the edited finding appear/disappear or resize as requested?
  4. Containment (C2): Do explicitly negated findings stay absent, and does anatomy >50 mm away shift no more than simply changing the random seed would cause?
  5. Reliability (C3): Does the edit consistently succeed or fail across multiple seeds (measured via Fleiss' $\kappa$)?
Unintended anatomical shift: adding fluid around the lungs causes a heart described as normal to grow.

Finally, CtrlCT outputs a diagnostic Report Card comparing every metric against both a "null control" (e.g., blurred scans or chance) and real CT benchmarks.

Datasets

  • CT-RATE: All evaluated models are tested on the validation split of CT-RATE, a public dataset of paired non-contrast chest CTs and radiology reports.
  • CtrlCT Benchmark Suites: From 940 validation scans (782 patients), the authors curate 687 targeted single-finding report edits: 567 adding or removing pleural effusion, and 120 enlarging or normalizing heart size (cardiomegaly). They release a Full suite (6,017 CTs per generator; 30,525 synthetic CTs generated across five benchmarked models) and a Lite suite (1,814 CTs) for cheaper testing of new models.

Key Insights and Ideas

  • Credibility and Control dissociate: Generating crisp, realistic CTs that match whole reports as a population does not mean a model can follow single-sentence edits. Standard metrics completely miss this failure.
  • Models learn whole-report correlations, not disentangled sentences: When a model does successfully add pleural effusion (like MedSyn), up to 14 out of 17 other unedited findings shift alongside it—matching real-world clinical co-occurrence—even when the report explicitly states those other findings are normal! Conversely, when an edit fails to remove an effusion, the model decides whether to keep the fluid based on what other diseases are mentioned in the rest of the text.
  • Moving with the text $\neq$ following the text: Replacing a radiology report with completely non-medical text shifts the output of models like GenerateCT and RAGText2CT as much as swapping in another patient's chest report—yet those exact models barely respond when asked to add pleural effusion.

Key Results

Benchmarking five public models (GenerateCT, MedSyn, Text2CT, MedSyn2, RAGText2CT) plus a sixth held-out model (CTFlow) revealed sharp tradeoffs:

  • The Realism vs. Control gap: RAGText2CT and Text2CT achieved the best population Realism among the main five (FD of 0.531 and 0.632, vs. 0.035 on real CTs) and top Report Agreement (0.73 and 0.74 AUROC). Yet when asked to add pleural effusion, they succeeded almost never (Effusion Add net effect of +0.05 and +0.02, where 1.00 is ideal). Meanwhile, MedSyn ranked fourth in Realism (0.801 FD) but best on Effusion Add (+0.57, jumping effusion presence from 5% to 62%).
  • Control is finding-dependent: Text2CT ranked dead last at adding fluid (+0.02), yet was among the most responsive at resizing the heart (+0.16 log-volume change for enlargement, +0.21 for normalization, vs. +0.37 in real CTs).
  • Silent pipeline failures: GenerateCT's text encoder truncates prompts at 256 tokens, silently dropping 148 of 567 effusion edits (producing voxel-identical CTs). Similarly, the held-out CTFlow achieved the best overall Realism (0.31 FD on Lite) but dropped 52% of effusion edits due to its 128-token window.
  • Seed instability: Population success rates across seeds looked rock-solid (SD $\le 0.011$), hiding case-level chaos: in MedSyn2, 48% of eligible effusion additions succeeded at some seeds and failed at others ($\kappa_+ = 0.36$).

Limitations and Future Work

  • Automated evaluators only: All measurements rely on automatic segmentation and classification models rather than human radiologists reading the synthetic CTs.
  • Focused scope: The benchmark evaluates one modality and anatomy (chest CTs from CT-RATE), testing two well-segmented findings across three random seeds, with diagnostic rules calibrated on five generators.
  • Future directions: Extending behavioral, metamorphic testing to other medical imaging modalities and anatomical regions, and designing next-generation Text-to-CT architectures with genuinely disentangled, sentence-level anatomical control.

Summary updated

Abstract

Recent advances in deep learning and the public availability of computed tomography (CT) datasets with paired reports have enabled many Text-to-CT generators. However, their evaluations almost always differ in preprocessing and metrics, which hinders comparison. Moreover, their protocols almost never test how editing the report changes the CT, not even at the same seed, so the report is often assumed to control the anatomy without evidence of how much and how consistently it does. We therefore propose CtrlCT, a toolkit that tests two properties of a generator, Credibility and Control. Credibility tests compare generated CTs, as a population, with real CTs and reports; Control tests are metamorphic and need no reference CT: at a fixed seed, editing one finding should change it as requested, keep negated findings absent and shift distant anatomy no more than a new seed, and the change should hold across seeds. A Report Card summarises all measures and insights for each generator. We benchmark five public generators on 940 chest CTs and 687 edits of pleural effusion and cardiomegaly, holding out a sixth to test the toolkit. Among them, the most credible generators barely respond to an added effusion, while the most responsive produce less realistic and less diverse CTs. The analyses proposed in the literature do not reveal this. We release CtrlCT, its edits, seeds and 30,525 synthetic CTs after acceptance.
BibTeX
@misc{panaccione2026one,
  author = {Francesca Pia Panaccione and Eugenio Lomurno and Matteo Matteucci},
  title = {{One, No One and One Hundred Thousand CTs: Testing Anatomical Control in Text-to-CT Generation}},
  year = {2026},
  eprint = {2611.33003},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.33003},
}
Figure