OC090: The use of serial measurements of inhibin A and activin A to predict the outcome of pregnancies of unknown location

E. Kirk, Aris T. Papageorghiou, Ben Van Calster, Sabine Van Huffel, Nicholas J. Cowans, Kaitlyn Spencer, T. BourneUltrasound 2008 · DOI

Abstract

At present serial measurements of serum human chorionic gonadotrophin (hCG) are often used to help predict the final clinical outcome of pregnancies of unknown location (PULs). It has been suggested that inhibin A is a specific marker of early pregnancy loss. Activin A is thought to be a marker of trophoblastic invasion with the potential to identify patients at risk of ectopic pregnancy (EP). The aim of this study was to evaluate the role of serial measurements of inhibin A and activin A in the prediction of the outcome of PULs. A prospective observational study on women classified as having a PUL attending an Early Pregnancy Unit. All women were followed up until the final pregnancy outcome was known—failing PUL, IUP or EP. Serum hCG, inhibin A and activin A levels were measured at presentation (0 hours) and 48 hours later. The mean hCG, inhibin and activin levels and the change in levels over 48 hours expressed as a ratio (48hrs/0hrs) were incorporated into multi-category logistic regression models to predict all pregnancy outcomes. The performance of the models was evaluated using receiver operator characteristic (ROC) curves. 141 women classified with PULs were included in the study. The final clinical outcomes were: 67 failing PULs (47.5%), 58 IUPs (41.1%) and 16 EPs (11.4%). The logistic regression model based on serum inhibin levels gave an area under the curve (AUC) of 0.896 for failing PUL, 0.878 for IUP and 0.648 for EP. The model based on serum activin levels gave an AUC of 0.591 for failing PUL, 0.596 for IUP and 0.544 for EP and finally the model based on serum hCG levels gave an AUC of 0.954 for failing PUL, 0.969 for IUP and 0.689 for EP. Serum activin A levels at 0 and 48 hours are not helpful in predicting the outcome of PULs. Although serum inhibin A levels may be of use in the prediction of failing PULs and IUPs, they do not perform as well as serum hCG levels.
BibTeX
@inproceedings{kirk2008oc,
  author = {E. Kirk and Aris T. Papageorghiou and Ben Van Calster and Sabine Van Huffel and Nicholas J. Cowans and Kaitlyn Spencer and T. Bourne},
  title = {{OC090: The use of serial measurements of inhibin A and activin A to predict the outcome of pregnancies of unknown location}},
  booktitle = {Ultrasound},
  year = {2008},
  doi = {10.1002/uog.5498},
}

Loading related content...