Observation of radon mitigation in MicroBooNE by a liquid argon filtration system
P. Abratenko, J. Anthony, L. Arellano, J. Asaadi, A. Ashkenazi, S. Balasubramanian, B. Baller, C. Barnes, G. Barr, J. Barrow, V. Basque, L. Bathe-Peters, O. Benevides Rodrigues, S. Berkman, A. Bhanderi, A. Bhat, Madhumita Bhattacharya, M. Bishai, A. Blake, T. Bolton, Julia Book, L. Camilleri, D. Caratelli, I. Caro Terrazas, F. Cavanna, G. B. Cerati, Y. Chen, D. Cianci, J. M. Conrad, M. R. Convery, L. Cooper-Troendle, J. I. Crespo-Anadón, M. Del Tutto, S. R. Dennis, P. Detje, Ann Devitt, R. Diurba, R. Dorrill, K. Duffy, S. Dytman, B. Eberly, A. Ereditato, J. J. Evans, R. Fine, G. A. Fiorentini Aguirre, R. S. Fitzpatrick, B. T. Fleming, N. Foppiani, D. Franco, A. P. Furmanski, D. García-Gámez, S. Gardiner, G. Ge, S. Gollapinni, O. Goodwin, E. Gramellini, P. Green, H. Greenlee, W. Gu, R. Guénette, P. Guzowski, L. Hagaman, O. Hen, C. Hilgenberg, G. A. Horton-Smith, A. Hourlier, R. Itay, C. James, X. Ji, L. Jiang, J. H. Jo, Cindy Joe, R. A. Johnson, Y.-j. Jwa, D. Kalra, N. Kamp, N. Kaneshige, G. Karagiorgi, W. Ketchum, M. Kirby, T. Kobilarcik, I. Kreslo, I. Lepetic, J.-y. Li, K. Li, Ye Li, K. Lin, B. R. Littlejohn, W. C. Louis, X. Luo, K. Manivannan, C. Mariani, D. Marsden, J. Marshall, D. A. Martínez Caicedo, K. Mason, A. Mastbaum, N. McConkey, V. Meddage, T. MettlerJournal of Instrumentation2022 · DOI · arXiv
The MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq $^{222}$Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. In the context of two models for radon mitigation via a liquid argon filtration system, a slowing mechanism and a trapping mechanism, MicroBooNE data supports a radon reduction factor of greater than 97% or 99.999%, respectively. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the $^{222}$Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs.
Introduction
In the world of rare-event physics, Radon-222 is a persistent "uninvited guest." It is a radioactive gas that emanates from the trace amounts of uranium found in almost all structural materials, from stainless steel pipes to concrete walls. For experiments using Liquid Argon Time Projection Chambers (LArTPCs), radon is a major headache because its decay products produce MeV-scale signals that can mimic the very physics researchers are trying to observe, such as low-energy neutrino interactions or dark matter scattering.
While many experiments use specialized gaseous filtration (like charcoal traps) to catch radon before it enters the detector, doing so in the liquid phase is significantly more challenging. This paper investigates whether the existing filtration systems used to keep argon chemically pure (removing oxygen and water) can also serve as a "radon trap."
Experimental Methods
The researchers utilized the MicroBooNE detector, an 85-metric-ton LArTPC at Fermilab. The experimental approach involved several key steps to test the filtration system's efficacy.
System Configuration
A 500 kBq $^{226}$Ra source was placed in the argon supply line to constantly emanate $^{222}$Rn gas into the detector's cryogenic system. The system could be operated in three modes: a filter-bypass mode to establish a baseline, a full-sized filter skid (77L molecular sieve and 77L copper-based filter), and a 30%-sized filter skid.
Schematic of the MicroBooNE cryogenic system showing the Radon-222 source injection point and the filtration skids.
To track radon activity within the TPC, the team utilized the "BiPo" coincidence signature. This occurs when Bismuth-214 ($\beta$-decays) is followed almost immediately (164 $\mu$s half-life) by Polonium-214 ($\alpha$-decays). This creates two distinct, spatially correlated energy depositions that are highly distinguishable from background cosmic rays.
Simulation of a BiPo coincidence event in the MicroBooNE LArTPC, showing the spatially correlated beta and alpha decays.
The most significant finding was that the copper-impregnated alumina (BASF CU-0226 S), originally designed for oxygen removal, was the primary agent removing the radon. A radiological survey of the filter tanks after the experiment showed a clear stratification of radiation peaking at the entrance of the copper medium, while the molecular sieve showed no significant accumulation.
Near-Perfect Filtration: When the filters were engaged, no appreciable increase in radon was detected in the TPC, even after 500 hours of continuous injection.
Quantitative Efficiency: Under a "Capture Model," the radon reduction factor was calculated to be >99.999%. Even under a more conservative "Slowing Model," the efficiency remained above 97.7%.
Liquid-Phase Success: This represents the first observation of high-efficiency radon mitigation in the liquid phase using a large-scale copper-based filter.
Discussion and Future Outlook
This discovery suggests that future large-scale experiments, such as DUNE, might not require separate, dedicated radon removal systems if their standard purity filters are already performing this function. However, several questions remain. The exact physical mechanism—whether surface adsorption or "freeze-out"—is not yet fully understood. Furthermore, for ultra-low-background experiments like those searching for dark matter, the intrinsic radon emanation of the filter material itself must be evaluated. Future work will focus on scaling these results to kiloton-scale detectors and ensuring that higher flow rates do not lead to "radon punch-through."
Summary updated
Abstract
Abstract The MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq 222 Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. In the context of two models for radon mitigation via a liquid argon filtration system, a slowing mechanism and a trapping mechanism, MicroBooNE data supports a radon reduction factor of greater than 97% or 99.999%, respectively. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the 222 Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs.
BibTeX
@article{abratenko2022observation,
author = {P. Abratenko and J. Anthony and L. Arellano and J. Asaadi and A. Ashkenazi and S. Balasubramanian and B. Baller and C. Barnes and G. Barr and J. Barrow and V. Basque and L. Bathe-Peters and O. Benevides Rodrigues and S. Berkman and A. Bhanderi and A. Bhat and Madhumita Bhattacharya and M. Bishai and A. Blake and T. Bolton and Julia Book and L. Camilleri and D. Caratelli and I. Caro Terrazas and F. Cavanna and G. B. Cerati and Y. Chen and D. Cianci and J. M. Conrad and M. R. Convery and L. Cooper-Troendle and J. I. Crespo-Anadón and M. Del Tutto and S. R. Dennis and P. Detje and Ann Devitt and R. Diurba and R. Dorrill and K. Duffy and S. Dytman and B. Eberly and A. Ereditato and J. J. Evans and R. Fine and G. A. Fiorentini Aguirre and R. S. Fitzpatrick and B. T. Fleming and N. Foppiani and D. Franco and A. P. Furmanski and D. García-Gámez and S. Gardiner and G. Ge and S. Gollapinni and O. Goodwin and E. Gramellini and P. Green and H. Greenlee and W. Gu and R. Guénette and P. Guzowski and L. Hagaman and O. Hen and C. Hilgenberg and G. A. Horton-Smith and A. Hourlier and R. Itay and C. James and X. Ji and L. Jiang and J. H. Jo and Cindy Joe and R. A. Johnson and Y.-J. Jwa and D. Kalra and N. Kamp and N. Kaneshige and G. Karagiorgi and W. Ketchum and M. Kirby and T. Kobilarcik and I. Kreslo and I. Lepetic and J.-Y. Li and K. Li and Ye Li and K. Lin and B. R. Littlejohn and W. C. Louis and X. Luo and K. Manivannan and C. Mariani and D. Marsden and J. Marshall and D. A. Martínez Caicedo and K. Mason and A. Mastbaum and N. McConkey and V. Meddage and T. Mettler},
title = {{Observation of radon mitigation in MicroBooNE by a liquid argon filtration system}},
journal = {Journal of Instrumentation},
year = {2022},
doi = {10.1088/1748-0221/17/11/p11022},
}