Numerical study on the effects of inlet swirling direction on the turbine guide vane full film cooling effectiveness

Zhong-yi Fu, Qiang Yu, Dan Zhao, Xinglong Fang, Qi HuangRanqi 2024 · DOI

TL;DR

Modern aero-engine combustors produce intense swirling flows that significantly alter how cooling air protects turbine blades. This study uses numerical simulations to demonstrate that the direction of this swirl—clockwise versus counterclockwise—drastically changes film cooling effectiveness across different regions of the turbine guide vane, meaning a "one-size-fits-all" cooling design is no longer sufficient.

What Problem Does This Paper Address?

In the quest for higher efficiency, modern jet engines operate at temperatures far exceeding the melting point of turbine materials. To survive, turbine vanes are "wrapped" in a thin layer of cool air—a technique called film cooling.

Traditionally, engineers designed these cooling systems assuming the hot gas entering the turbine was a uniform, straight-line flow. However, new "lean-burn" combustors use fuel nozzles that create powerful swirling flows. This residual swirl doesn't just disappear; it hits the first stage of turbine vanes, deflecting the protective cooling film and creating "hot spots." The authors set out to quantify exactly how the direction of this swirl (clockwise vs. counterclockwise) changes the cooling performance on the leading edge, pressure side, and suction side of the vane.

Methods

The researchers employed 3D Reynolds-Averaged Navier-Stokes (RANS) numerical simulations. Key aspects of their setup include:

  • Physical Model: A two-part geometry consisting of a swirler section (to generate the vortex) followed by a turbine guide vane cascade.
  • Computational Fluid Dynamics (CFD): They used the SST (Shear Stress Transport) turbulence model, which is a standard for capturing flow separation near walls, and the Total Energy model for heat transfer.
  • Boundary Conditions: Mainstream inlet pressure was set at 1.47 MPa, with a secondary cooling air inlet at 1.52 MPa. They tested a swirl intensity of 0.5 in both clockwise (CW) and counterclockwise (CCW) directions (viewed from upstream looking downstream).

Datasets

As a numerical study, the paper does not use external training datasets. Instead, it generates its own data through high-fidelity simulations based on a reference aero-engine model. The "benchmark" for comparison is the performance difference between the two swirl directions across specific vane regions (Leading Edge, Pressure Side, Suction Side).

Key Insights and Ideas

  • Directional Asymmetry: Swirl direction isn't just a mirror image; it fundamentally redistributes the high-velocity zones at the vane inlet. For CCW swirl, the high-velocity zone hits the bottom (hub) of the suction side; for CW swirl, it hits the top (shroud).
  • Coolant Deflection: The swirl acts like a crosswind for the cooling film. On the leading edge, CCW swirl pushes the coolant toward the hub, while CW swirl pushes it toward the shroud. This leaves large areas of the vane unprotected depending on the rotation.
  • Regional Sensitivity: The "best" swirl direction depends on which part of the vane you are looking at. The pressure side (the "belly" of the blade) prefers CCW swirl, while the leading edge and suction side (the "back") are better protected by CW swirl.
  • Vortex Interaction: The swirl interacts with the vane's own secondary flows to create complex vortices. In CW conditions, two distinct vortices appear at the top of the vane, which actually helps spread the cooling film more effectively in that specific region.

Key Results

The study provides clear quantitative winners for cooling effectiveness ($\eta$):

  • Pressure Side (PS): CCW swirl is superior. The area-averaged cooling effectiveness was approximately 0.31 for CCW vs. 0.23 for CW.
  • Leading Edge (LE): CW swirl performs significantly better, with an effectiveness of 0.17 compared to 0.10 for CCW.
  • Suction Side (SS): CW swirl holds a slight edge, at 0.29 vs. 0.27 for CCW.
  • Overall Trend: While the pressure side is better protected under CCW swirl, the leading edge—the most thermally stressed part of the vane—suffers significantly. Conversely, CW swirl provides a more balanced (though still non-uniform) cooling distribution across the leading edge and suction side.

Limitations and Future Work

The authors acknowledge a few areas for further exploration:

  • Steady-State vs. Transient: The study uses steady-state RANS simulations. Real engine flows are highly turbulent and unsteady, which might further dilute the cooling film.
  • Swirl Intensity: The study focused on a swirl intensity of 0.5. Future work could examine how varying the "strength" of the vortex changes these patterns.
  • Experimental Validation: While the numerical methods are standard, the paper notes that specific experimental data for full-film cooling under these exact swirling conditions is still relatively scarce in open literature.

This research highlights that as combustor technology evolves, turbine cooling design must move away from "uniform flow" assumptions and start accounting for the specific "fingerprint" of the upstream swirl.

Summary updated

Abstract

To obtain film cooling characteristics for a turbine guide vane under inlet swirling conditions, the effects of clockwise and counterclockwise inlet swirling on the gas turbine first-stage guide vane full film cooling effectiveness were analyzed by numerical simulation. The variation rules of cooling effectiveness of the leading edge, pressure side and suction side were summarized respectively. The results show that the swirling direction of the inlet has an obvious influence on the film cooling effectiveness of the guide vane, and the cooling effectiveness in different regions is affected by the swirling direction differently. The coolant on the vane surface is deflected by swirling flow. On the whole, the film cooling effectiveness of the pressure side of the guide vane is higher when the swirling direction is counterclockwise. The film cooling effectiveness of the leading edge and suction side is higher when the direction of swirl is clockwise.