Numerical Simulations of Air Flow and Traffic–Related Air Pollution Distribution in a Real Urban Area

Mengge Zhou, Tingting Hu, Guoyi Jiang, Wenqi Zhang, Dan Wang, Pinhua RaoEnergies 2022 · DOI

TL;DR

This study uses CFD simulations to model air flow and traffic-related pollution in a real Shanghai urban area, considering both ground-level and viaduct sources. It reveals how urban geometry influences pollutant dispersion and highlights that while ground-level sources dominate at lower heights, viaduct sources become more significant above 8 meters, with complex interactions around buildings.

What Problem Does This Paper Address?

Urbanization leads to increased air pollution, posing significant health risks. Understanding how traffic-related pollutants disperse within complex urban environments is crucial for developing effective mitigation strategies. Previous studies often relied on idealized urban blocks or limited ground-level monitoring, failing to capture the full picture of pollutant spread from both ground and elevated traffic sources in a realistic urban setting. This paper aims to bridge this gap by simulating pollutant dispersion in a real urban area, considering its intricate geometry and multiple pollution sources.

Methods

The researchers employed Computational Fluid Dynamics (CFD) simulations using ANSYS Fluent 2020. They utilized the standard k-ε turbulence model, a common approach for airflow calculations. The simulation domain was meshed with an unstructured polyhedral mesh, refined near building surfaces and ground for better accuracy. Two passive scalar transport equations were solved to simulate pollutant dispersion from both ground-level and viaduct sources. The study also defined and analyzed several ventilation efficiency indices, including the Spatially-Averaged Wind Velocity Ratio (VRw) and Spatially-Averaged Normalized Concentration (C*).

Datasets

The study used meteorological observation data from nearby weather stations for boundary conditions. It also referenced wind tunnel data from a previous study [62] for CFD model validation. The urban area itself, a real block in Shanghai, served as the geometric basis for the simulation.

Key Insights and Ideas

  • Geometry is King: Local urban geometry dictates ventilation patterns. Even in a real urban setting, the arrangement of buildings significantly influences how air and pollutants move.
  • Source Height Matters: The relative contribution of ground-level versus viaduct pollution sources changes with height. Ground sources are dominant below 8 meters, but viaduct sources become more significant at higher altitudes.
  • Complex Vertical Profiles: Pollutant concentration doesn't simply decrease with height. It shows irregular increases and decreases, especially between 60 and 86 meters, often linked to high-rise building clusters.
  • Building-Specific Behavior: Vertical pollutant profiles are unique to each building, influenced by its specific shape and surrounding environment.
  • Windward vs. Leeward Differences: The relationship between pollutant concentration and wind speed/turbulence varies significantly between the windward and leeward sides of buildings, with upstream buildings showing a stronger correlation on the windward side.
  • Morphology vs. Pedestrian Level: At the pedestrian level, the studied urban morphological parameters showed surprisingly little correlation with ventilation indices, suggesting other factors might be more dominant at this scale.

Key Results

  • Pollutants released at ground level were dominant below 8 meters.
  • Pollutants from viaduct sources were 0.8–6.1% higher than ground sources above 8 meters.
  • Spatially-averaged normalized concentration (C*) generally decreased with distance from the source up to 60 meters, then increased irregularly between 60-86 meters, and increased linearly above 86 meters.
  • Vertical pollutant concentration profiles around buildings were building-specific and inconsistent in their rate of change with height.
  • Correlations between pollutant concentration (C*) and wind velocity ratio (VRw) were generally stronger on the windward side of upstream buildings compared to the leeward side.
  • Seven urban morphological parameters showed no significant correlation with ventilation indices at the pedestrian level.

Limitations and Future Work

The authors acknowledge that the study focused on a single urban block and a specific set of wind conditions. They suggest that future work should involve designing more diverse urban blocks and considering a wider range of wind angles to better understand the correlation between urban form factors and ventilation. The lack of significant correlation between urban form parameters and pedestrian-level ventilation indices also warrants further investigation with more varied urban designs.

Summary updated

Abstract

With increasing urbanization, urban air pollutants are becoming more and more relevant to human health. Here, combined with meteorological observation data, a numerical simulation of typical urban blocks in Shanghai was carried out to understand the spread of air pollutants caused by road traffic sources (ground–level and viaduct–level). Firstly, we analyzed the wind environment characteristics. Then, we quantitatively analyzed the pollutant distribution profiles and the contributions of two pollutant sources (PSV). Finally, we analyzed seven urban morphological parameters based on ventilation efficiency indices. Results revealed the following. (1) Ventilation patterns within the architectural complex are determined by local geometry; (2) Pollutants released at ground level were dominant when the Z–plane < 8 m high, and pollutants released from the viaduct source were 0.8–6.1% higher when the Z–plane ≥ 8 m high; (3) From ground level to a height of 60 m, the spatially–averaged normalized concentration (C*) tended to decrease gradually with distance from the source. C* increased irregularly with an increase in distance between 60 m and 86 m. Above 86 m, C* tended to increase linearly; (4) Vertical profiles of C* around buildings were building–specific, and their rate of change was inconsistent with height increases. In general, the correlations between C* and VRw, and between C* and KEturb were larger on the windward side of PSV upstream buildings than on the leeward side. Buildings downstream of the PSV showed the opposite situation; (5) At pedestrian level, the seven urban morphological parameters had no significant correlation with VRw, Cir*, and Czs*.
BibTeX
@inproceedings{zhou2022numerical,
  author = {Mengge Zhou and Tingting Hu and Guoyi Jiang and Wenqi Zhang and Dan Wang and Pinhua Rao},
  title = {{Numerical Simulations of Air Flow and Traffic–Related Air Pollution Distribution in a Real Urban Area}},
  booktitle = {Energies},
  year = {2022},
  doi = {10.3390/en15030840},
}
Figure