Numerical simulation of variable load combustion in a 600 MW supercritical pulverized coal boiler
Abstract
Abstract In the context of the ongoing development of renewable energy sources, coal-fired units are undergoing a gradual transformation into auxiliary power sources. Consequently, there is an urgent need to enhance the deep-peaking capability of these units. The present paper investigates the combustion behavior of a pulverized coal boiler across four different operational scenarios of 360 MW, 300 MW, 240 MW, and 180 MW using CFD numerical simulation. The boiler in question is a 600 MW supercritical cyclone hedge boiler. The results demonstrate a decline in the aggregate temperature within the furnace chamber with a reduction in load, coal feed, and air supply. At 60%, 50%, 40%, and 30% of the rated load, the NOx concentrations at the furnace outlet are 481.56 ppm, 477.01 ppm, 472.32 ppm, and 469.63 ppm, respectively. With a decrease in the boiler load, a downward trend in the NOx concentrations at the furnace outlet is evident.
BibTeX
@article{fu2025numerical,
author = {Xiaoxiao Fu and Hao Lü and Chuanxiao Zheng and Rui Jü and Jiaqi Li},
title = {{Numerical simulation of variable load combustion in a 600 MW supercritical pulverized coal boiler}},
journal = {Journal of Physics Conference Series},
year = {2025},
doi = {10.1088/1742-6596/3092/1/012007},
}Ask Althea to put this paper to the test.