NUMERICAL SIMULATION OF DECAY HEAT REMOVAL AFTER CEFR SCRAM
Lists
Only you see this
Abstract
This paper analyzes the process of decay heat removal after Chinese Experimental Fast Reactor(CEFR)scram. The 3 D Thermal hydraulic analysis with porous media method is applied in hot plenum, 1 D system analysis is used in three loops of core, decay heat exchanger (DHX)and air cooling tower. In the calculation, 3 D and 1 D are coupled with each other to simulate transient process of decay heat removal. Many important numerical results, such as core outlet temperature variation, the highest temperature of cladding and removal power of DHX etc., are presented and discussed in this paper. They provide valuable reference for the design and safety assessment of CEFR.
BibTeX
@inproceedings{liao1999numerical,
author = {Zhenyu Liao and Feiyong Yang},
title = {{NUMERICAL SIMULATION OF DECAY HEAT REMOVAL AFTER CEFR SCRAM}},
booktitle = {CHINESE},
year = {1999},
}Loading related content...