Novel Domain Knowledge-Encoding Algorithm Enables Label-Efficient Deep Learning for Cardiac CT Segmentation to Guide Atrial Fibrillation Treatment in a Pilot Dataset

Prasanth Ganesan, Ruibin Feng, Brototo Deb, Fleur V.y. Tjong, Albert J. Rogers, Samuel Ruipérez-Campillo, Sulaiman Somani, Paul Clopton, Tina Baykaner, Miguel Rodrigo, James Zou, François Haddad, Matei Zaharia, Sanjiv M. NarayanDiagnostics 2024

TL;DR

This paper introduces DOKEN, a novel algorithm that leverages "anatomical knowledge" from digital models to automatically label cardiac CT scans. This label-efficient approach significantly reduces the need for large annotated datasets, enabling high-performance deep learning segmentation for guiding atrial fibrillation treatment.

What Problem Does This Paper Address?

Accurate segmentation of cardiac structures, particularly the left atrium (LA) and its substructures (pulmonary veins and left atrial appendage), is crucial for planning treatments like atrial fibrillation (AF) ablation. While deep learning (DL) models excel at segmentation, they typically require vast amounts of meticulously labeled training data. Acquiring such large datasets for medical imaging is challenging due to privacy concerns, the cost of expert annotation, and the inherent variability in patient anatomy. This scarcity of labeled data limits the widespread adoption and effectiveness of DL in clinical settings. The paper aims to bridge this gap by developing a method that achieves high segmentation accuracy with significantly fewer labeled training examples.

Methods

The core innovation is the Domain Knowledge-Encoding (DOKEN) algorithm. DOKEN works in two main stages:

  1. Segmentation of Digital LA Models: DOKEN begins by processing publicly available digital 3D LA models. It uses an iterative erosion-dilation process to separate the LA body from its substructures (pulmonary veins and left atrial appendage). This process is carefully controlled using an "Erosion Index" and a "Dilation Index" to ensure accurate boundary refinement.
  2. Tuning ED Parameters using Patient LA Models: To adapt the digital model-derived parameters to real-world clinical data, DOKEN uses a small set of manually annotated patient LA models (N=5). Support Vector Machines (SVMs) are trained on these models to predict the optimal erosion and dilation parameters for clinical CT scans.

Once developed, DOKEN takes raw CT images as input and automatically generates robust ground-truth labels for the LA substructures. These DOKEN-generated labels are then used to train a nnU-Net deep neural network (DNN). The nnU-Net model, a well-established architecture for medical image segmentation, is trained on a small set of DOKEN-labeled CT scans (N=20) and subsequently evaluated on a much larger hold-out test set (N=100).

Datasets

  • Digital LA Models: N=6 publicly available 3D digital heart models were used for developing the DOKEN algorithm's core segmentation logic.
  • Patient LA Models for Tuning: N=5 manually segmented patient LA models were used to tune the DOKEN algorithm's parameters for clinical data.
  • Training Set: N=20 cardiac CT scans from patients who underwent AF ablation were used for training the nnU-Net model, with labels generated by the DOKEN algorithm.
  • Test Set: N=100 cardiac CT scans from patients who underwent AF ablation were used for evaluating the performance of the DOKEN-trained nnU-Net model. This set was manually annotated by clinical experts.

The key difference in this study is the inversion of the typical training-to-test ratio. Instead of a large training set and a smaller test set, this work uses a small training set (N=20) and a significantly larger test set (N=100), achieving a ratio of 1:5.

Key Insights and Ideas

  • "Anatomical Knowledge" as a Data Augmentation Tool: The paper demonstrates that encoding domain-specific anatomical knowledge can act as a powerful form of data augmentation, effectively creating high-quality labels from limited manual annotations.
  • Bridging the Gap Between Digital and Real Data: The two-step DOKEN process, moving from digital models to tuning with real patient data, is crucial for making the learned anatomical principles applicable to clinical scans, which often contain artifacts and anatomical variations.
  • Label Efficiency is Key: The core insight is that by intelligently incorporating prior knowledge, the dependency on massive labeled datasets can be drastically reduced, making advanced ML techniques more accessible for clinical applications.
  • Human-like Learning: The authors draw an analogy to how humans can learn from few examples by understanding underlying principles, suggesting that DOKEN emulates this by encoding geometric and anatomical rules.

Key Results

The DOKEN-enhanced nnU-Net model achieved impressive segmentation performance on the hold-out test set (N=100) with a training set of only N=20:

  • Dice Score: 96.7% (IQR: 95.3% to 97.7%), indicating excellent overlap between predicted and ground-truth segmentations.
  • Median Surface Distance Error: 1.51 mm (IQR: 0.72 to 3.12 mm).
  • Mean Centroid-Boundary Distance: 1.16 mm (95% CI: -4.57 to 6.89), which was comparable to expert results (r = 0.99; p < 0.0001).
  • In Digital Hearts: The DOKEN approach itself achieved a mean centroid-boundary distance of -0.27 mm (95% CI: -3.87 to 3.33) when segmenting digital LA structures, demonstrating its accuracy on idealized models.
  • Training-to-Test Ratio: The study achieved a training-to-test ratio of 1:5, a significant reduction compared to typical ratios of >3:1 in the field.

Limitations and Future Work

  • Generalizability to Diverse Anatomies: While the algorithm performed well on common anatomical variants, it encountered some challenges with less common ones (e.g., missing PVs or branches). The authors suggest that adapting geometric models to a wider range of PV configurations could improve performance.
  • Single-Center Study: The current dataset is from a single center. Future work should involve larger, multi-center datasets to further validate and refine the algorithm's generalizability.
  • Expert Adjudication: For more robust labeling, future studies could incorporate a fusion of annotations from multiple experts with an adjudication committee to resolve discrepancies.
  • Broader Applications: The authors envision extending this domain knowledge-encoding approach to other imaging modalities, 3D printing applications (e.g., via smoothing filters), and other data science domains beyond medical imaging.

Summary updated

Abstract

<b>Background:</b> Segmenting computed tomography (CT) is crucial in various clinical applications, such as tailoring personalized cardiac ablation for managing cardiac arrhythmias. Automating segmentation through machine learning (ML) is hindered by the necessity for large, labeled training data, which can be challenging to obtain. This article proposes a novel approach for automated, robust labeling using domain knowledge to achieve high-performance segmentation by ML from a small training set. The approach, the domain knowledge-encoding (DOKEN) algorithm, reduces the reliance on large training datasets by encoding cardiac geometry while automatically labeling the training set. The method was validated in a hold-out dataset of CT results from an atrial fibrillation (AF) ablation study. <b>Methods:</b> The DOKEN algorithm parses left atrial (LA) structures, extracts "anatomical knowledge" by leveraging digital LA models (available publicly), and then applies this knowledge to achieve high ML segmentation performance with a small number of training samples. The DOKEN-labeled training set was used to train a nnU-Net deep neural network (DNN) model for segmenting cardiac CT in <i>N</i> = 20 patients. Subsequently, the method was tested in a hold-out set with <i>N</i> = 100 patients (five times larger than training set) who underwent AF ablation. <b>Results:</b> The DOKEN algorithm integrated with the nn-Unet model achieved high segmentation performance with few training samples, with a training to test ratio of 1:5. The Dice score of the DOKEN-enhanced model was 96.7% (IQR: 95.3% to 97.7%), with a median error in surface distance of boundaries of 1.51 mm (IQR: 0.72 to 3.12) and a mean centroid-boundary distance of 1.16 mm (95% CI: -4.57 to 6.89), similar to expert results (r = 0.99; <i>p</i> < 0.001). In digital hearts, the novel DOKEN approach segmented the LA structures with a mean difference for the centroid-boundary distances of -0.27 mm (95% CI: -3.87 to 3.33; r = 0.99; <i>p</i> < 0.0001). <b>Conclusions:</b> The proposed novel domain knowledge-encoding algorithm was able to perform the segmentation of six substructures of the LA, reducing the need for large training data sets. The combination of domain knowledge encoding and a machine learning approach could reduce the dependence of ML on large training datasets and could potentially be applied to AF ablation procedures and extended in the future to other imaging, 3D printing, and data science applications.
BibTeX
@inproceedings{ganesan2024novel,
  author = {Prasanth Ganesan and Ruibin Feng and Brototo Deb and Fleur V.Y. Tjong and Albert J. Rogers and Samuel Ruipérez-Campillo and Sulaiman Somani and Paul Clopton and Tina Baykaner and Miguel Rodrigo and James Zou and François Haddad and Matei Zaharia and Sanjiv M. Narayan},
  title = {{Novel Domain Knowledge-Encoding Algorithm Enables Label-Efficient Deep Learning for Cardiac CT Segmentation to Guide Atrial Fibrillation Treatment in a Pilot Dataset}},
  booktitle = {Diagnostics},
  year = {2024},
  doi = {10.3390/diagnostics14141538},
}
Figure