Abstract
This paper presents a multi-person gait monitoring system designed for efficient operation in cluttered environments. The system demonstrates robust capabilities in tracking multiple closely spaced individuals and accurately extracting walking speed, even in the presence of others. We address two significant challenges: enhancing radar resolution and mitigating multipath effects in cluttered settings. Our method shows remarkable accuracy, with a maximum error of 0.33 m/s and a minimum of 0.005 m/s, as validated through 25 walking tests in a bedrest study. Its adaptability makes it a valuable clinical tool, offering insights for predicting underlying health issues in older adults.
Introduction
Walking speed is increasingly recognized as a critical "functional vital sign." For older adults, it serves as a powerful predictor of frailty, hospitalization risk, and recovery trajectories. Despite its clinical importance, current measurement methods are often impractical for continuous monitoring. Gold-standard systems like GaitRite mats or Vicon motion capture are expensive and require dedicated clinical space. Furthermore, the presence of observers or specialized equipment can lead to the "white coat effect," where patients alter their natural gait due to being watched.
Overcoming Environmental Challenges
Radar-based sensors offer a promising, privacy-preserving, and contactless alternative to cameras and wearables. However, real-world environments like hospital hallways present two major technical hurdles:
- Multipath Effects: Radio waves reflect off walls, stretchers, and furniture, creating "ghost" signals that mimic human movement.
- Low Angular Resolution: Standard radar hardware often struggles to distinguish between two individuals walking in close proximity, merging them into a single data cluster.
Algorithmic Innovation
The system utilizes a 77–81 GHz mm-wave FMCW (Frequency-Modulated Continuous Wave) radar. The core innovation lies in a specialized software pipeline designed to overcome hardware limitations:
- 1D-Azimuth Clustering Algorithm (1D-ACA): This algorithm refines standard clustering techniques to split merged data points, allowing the system to resolve individuals even when they are walking close together.
- Subjects Tracker and Association (STA) Algorithm: The STA algorithm acts as the system's "brain," using temporal logic to filter noise. It distinguishes real subjects from "ghosts" by requiring consistent movement over time and ensuring speeds remain within realistic human thresholds (set at 4 m/s).
Experimental Validation
The system was validated during a 14-day bedrest (BR) study involving 22 healthy adults aged 55–65. Participants performed walking tests in a 14-meter hallway before and after a period of enforced inactivity. The radar system tracked participants alongside research assistants, providing a rigorous test of its multi-person tracking capabilities. Ground truth was established using manual stopwatch measurements recorded by the assistants.
Results and Discussion
The system demonstrated high accuracy across 25 walking tests, with errors ranging from a negligible 0.005 m/s to a maximum of 0.33 m/s. Statistical analysis via a Bland-Altman plot revealed a mean bias of only -0.0644 m/s, indicating excellent agreement with manual measurements. The authors noted that this minor bias is trivial given the inherent human error in manual timing.
Crucially, the system was sensitive enough to detect the expected decline in gait speed immediately following the bedrest period (the "R+1" phase) and the subsequent recovery over four weeks. This sensitivity matches trends found in clinical literature, demonstrating the system's utility as a diagnostic and monitoring tool.
Conclusion
By combining advanced signal processing with temporal logic, this radar-based system successfully monitors gait speed in complex, multi-person environments without the need for cameras or wearable sensors. While future work will aim to use more precise ground truth (such as GaitRite mats) and larger sample sizes, these results suggest a viable path toward non-intrusive, continuous health monitoring in clinical and residential settings.