TL;DR
This paper introduces a novel, non-contact method for monitoring fetal movement (FM) using only abdominal video recordings. By analyzing optical flow patterns, the system accurately detects and quantifies FM parameters, offering a convenient and potentially more comfortable alternative to existing methods for both clinical and home use.
What Problem Does This Paper Address?
Fetal movement (FM) is a critical indicator of fetal health and neurobehavioral development, serving as an early warning sign for potential adverse outcomes like intrauterine growth restriction or stillbirth. Current methods for monitoring FM, however, have significant drawbacks. Ultrasound, while effective, requires skilled clinicians and raises concerns about potential harm from prolonged exposure. Wearable sensors, though offering continuous monitoring, can be uncomfortable, require precise placement, and struggle to differentiate fetal movements from maternal interference. Maternal self-counting is subjective, prone to inaccuracies due to various influencing factors, and challenging for long-term observation. This leaves a clear need for a non-contact, objective, and user-friendly method for reliable FM monitoring.
Methods
The proposed method leverages computer vision and signal processing techniques to extract FM signals from abdominal videos. The core steps include:
- Maternal Abdominal Region Detection: Initially, frames with significant maternal movement are removed. Then, an ellipse skin model is used to isolate the abdominal region, followed by an "open operation" to clean up the segmentation.
- Optical Flow Color-Coding: Optical flow algorithms are employed to capture the motion within the detected abdominal region. The direction and magnitude of pixel velocity are then encoded into Hue (H) and Saturation (S) channels of an HSL color space. This visually represents the subtle movements associated with FM.
- Signal Decomposition and FM Determination: The H and S signals are preprocessed (e.g., high-pass filtering) and then decomposed into intrinsic mode functions (IMFs) using Ensemble Empirical Mode Decomposition (EEMD) to remove noise and isolate relevant signal components. The FM signal is determined by combining an energy ratio and a Spearman correlation coefficient across these IMFs.
- Fetal Movement Spike Recognition: FM spikes, indicative of FM events, are identified by analyzing the first and second-order differences of the determined FM signal. A two-tiered thresholding system (Th1 and Th2) is used to distinguish true FM spikes from noise or non-FM related movements.
- FM Parameter Calculation: Once FM spikes are identified, key parameters are calculated: FM number (counting distinct FM events per hour, with a rule to group spikes within 6 seconds as one event), FM interval (time between consecutive FMs), FM duration (time between spikes), and FM percentage (total FM duration relative to recording time).
Datasets
The study utilized abdominal videos from 5 pregnant women recorded between 28 and 36 gestational weeks (GWs). A total of 18 videos were initially collected, with 2 excluded due to poor quality, leaving 16 videos for analysis. The "gold standard" for evaluation was manual labeling of FM by two experienced professionals who reviewed the abdominal videos.
Key Insights and Ideas
- Optical Flow as a Non-Contact Motion Sensor: The paper effectively demonstrates how optical flow, a standard computer vision technique, can be repurposed to capture subtle, localized movements indicative of fetal activity without any physical contact.
- HSL Color Space for Motion Encoding: Encoding optical flow vectors into H and S channels provides a robust way to represent motion characteristics, allowing for subsequent signal processing.
- EEMD for Signal Purification: The use of EEMD is crucial for denoising the H and S signals, enabling the extraction of cleaner FM signals that are less susceptible to maternal interference or environmental noise.
- Dual Thresholding for Spike Detection: The two-stage thresholding approach for FM spike recognition is a clever way to balance sensitivity and specificity, reducing false positives while capturing genuine FM events.
- Comprehensive FM Parameterization: Beyond just detecting FM, the method quantifies key parameters (number, interval, duration, percentage), providing a richer dataset for clinical assessment than simple detection.
- S Signal Superiority: The finding that the S signal (representing intensity/amplitude of movement) performed better than the H signal (representing direction) suggests that the force or magnitude of fetal movement is a more discriminative feature for detection in this context.
Key Results
The proposed method achieved impressive performance metrics:
- Detection Accuracy: True Detection Rate (TDR) of 95.75%, Positive Predictive Value (PPV) of 95.26%, Sensitivity (SEN) of 95.75%, Accuracy (ACC) of 91.40%, and F1_score of 95.50% when using the S signal.
- Parameter Agreement: Bland-Altman analysis showed good agreement between the proposed method's FM parameters and those manually labeled by professionals, with small mean differences and differences falling within 95% confidence intervals.
- Gestational Week Trends: Analysis of one pregnant woman's data revealed expected trends: FM number, duration, and percentage decreased with increasing gestational week, while FM interval increased, aligning with physiological expectations.
Limitations and Future Work
- Maternal Interference: The current method requires pregnant women to lie motionlessly. The authors acknowledge that maternal activity is inevitable during long-term monitoring and suggest future work should focus on automatic detection and removal of this interference.
- Limited Dataset Size: The study involved a small number of participants (5 women, 16 videos). Future work should recruit more volunteers, including those in different trimesters and with varying pregnancy outcomes, to validate the findings more broadly.
- Feasibility Study: The authors emphasize that this was a feasibility study, not an extensive clinical trial. Further validation in clinical practice is needed.
- Discriminating FM Types: While the current method detects FM, future research could explore using machine learning to differentiate various types of fetal movements (e.g., kicking, stretching) for more detailed analysis.
- Comparison with Contact Methods: The paper suggests applying both non-contact and contact methods simultaneously on pregnant women to compare their efficiency.
Summary updated