Non-Contact Blood Pressure Monitoring Using Radar Signals: A Dual-Stage Deep Learning Network

Pengfei Wang, Minghao Yang, Xiaoxue Zhang, Jianqi Wang, Cong Wang, Hongbo JiaBioengineering 2025

TL;DR

This paper introduces a novel dual-stage deep learning network that uses radar signals to non-invasively monitor blood pressure (BP) with high accuracy. By combining a ResNet for spatial feature extraction and a Transformer for temporal analysis, the system achieves clinically acceptable errors and can estimate BP at 2-second intervals, paving the way for continuous, beat-to-beat BP monitoring without physical contact.

What Problem Does This Paper Address?

Hypertension is a growing global health concern, and continuous blood pressure (BP) monitoring is crucial for early diagnosis, treatment tracking, and reducing mortality. Traditional cuff-based methods are intermittent and can be uncomfortable, while existing non-contact methods often struggle with accuracy due to physiological noise and require complex feature engineering. This paper aims to overcome these limitations by developing a robust, non-contact BP monitoring system using radar signals, offering a more comfortable and potentially real-time solution.

Methods

The core of this work is a dual-stage deep learning network.

  • Preprocessing: The radar signals, specifically chest wall vibrations (RCMV), are preprocessed to isolate cardiogenic signals. This involves band-pass filtering, downsampling, and trend decomposition. Crucially, the second-order derivative of the RCMV (SDRCMV) is also computed and used as a second input channel, leveraging its known correlation with BP fluctuations.
  • Stage 1 (ResNet): A ResNet-18 architecture is employed to extract spatial features from the dual-channel RCMV and SDRCMV inputs. This stage also provides initial estimates of systolic (SBP) and diastolic (DBP) blood pressure.
  • Stage 2 (Transformer): A Transformer network takes the features extracted by the ResNet, along with the initial SBP/DBP estimates from Stage 1, as input. This stage focuses on modeling temporal dependencies and correlations within the pulse waveform, further refining the BP estimation. The early BP estimates from Stage 1 are used to augment the feature set for Stage 2, enhancing its predictive power.

Datasets

The study utilized a publicly available dataset [43] comprising physiological signals from 30 healthy subjects. This dataset includes synchronized radar and BP measurements collected under various experimental conditions (resting, breath-holding, Valsalva maneuvers, tilt-table tests) at a high sampling rate (2000 Hz for radar, 200 Hz for BP). The data was partitioned into 65% for training, 15% for validation, and 20% for testing.

Key Insights and Ideas

  • The Power of the Second Derivative: Using the second-order derivative of the radar chest micro-vibration signal (SDRCMV) as a supplementary input channel significantly enhances the model's ability to capture BP dynamics. This highlights how subtle signal transformations can unlock crucial information.
  • Hierarchical Feature Extraction: The two-stage approach, where a ResNet handles spatial features and a Transformer models temporal dynamics, is highly effective. This synergy allows for a more comprehensive understanding of the complex radar signals related to BP.
  • Cascaded Prediction for Augmentation: Using the initial BP estimates from the first stage (ResNet) to augment the input features for the second stage (Transformer) is a clever way to leverage inter-stage information and improve overall accuracy. This demonstrates how early predictions can inform later, more complex stages.
  • Short Window for Beat-to-Beat: Achieving clinically acceptable accuracy with a 2-second window is a significant step towards real-time, beat-to-beat BP monitoring, which is a major goal in cardiovascular health.

Key Results

  • Clinically Acceptable Accuracy: The model achieved clinically acceptable errors: SBP: -1.09 ± 5.15 mmHg and DBP: -0.26 ± 4.35 mmHg. These values meet the AAMI standard requirements for BP devices (ME within ±5 mmHg, SD below 8 mmHg).
  • BHS Grade A Performance: For a 2-second window, the model achieved "Grade A" performance according to BHS criteria, with error frequencies of 62.74% (<5 mmHg) and 87.42% (<10 mmHg) for SBP, and 75.49% (<5 mmHg) and 93.15% (<10 mmHg) for DBP.
  • Real-time Approximation: The ability to estimate BP at 2-second intervals (0.5 Hz sampling rate) closely approximates real-time, beat-to-beat monitoring.
  • Comparative Performance: The proposed method outperformed or matched state-of-the-art non-contact BP monitoring techniques across various metrics (MAE, RMSE, MRE) in comparative analyses.

Limitations and Future Work

  • Dataset Constraints: The study acknowledges a limitation due to a constrained dataset, which hindered the model's ability to capture a broader spectrum of BP readings. The dataset primarily included healthy individuals and did not extensively cover pediatric populations or confirmed hypertensive cohorts, limiting generalizability.
  • Medical Conditions: The model's performance might be affected by medical conditions that reduce the correlation between SBP and DBP (e.g., isolated systolic hypertension, aortic stenosis).
  • Accuracy Gap: While promising, the accuracy gap with gold-standard sphygmomanometry still needs to be addressed.
  • Future Directions:
    • Population-Representative Database: Creating a larger, more diverse database including various age groups, health conditions, and demographics is crucial for robust models.
  • Next-Generation Architectures: Integrating advanced architectures like graph networks could further improve model precision.
  • Enhanced Radar Systems: Employing MIMO radar with adaptive beamforming could improve signal resolution for capturing subtler pulse signals and richer waveform features.
  • Broader Physiological Parameters: Investigating the integration of additional physiological parameters could expand the system's monitoring capabilities.

Summary updated

BibTeX