New Sustain Waveform for Improving Luminous Efficiency in Wide-Gap Plasma-Display Panel

Hyun Kim, Heung‐Sik TaeIEEE Transactions on Electron Devices 2008 · DOI

Abstract

The three-electrode microdischarge characteristics of ac-plasma-display panels (PDPs) are analyzed with a wide sustain discharge gap of 180 mum. In particular, the luminous efficiency variation is examined as a parameter of the operating frequency. It is found that the luminous efficiency decreases with an increase in the operating frequency. In other words, a failure discharge mode for luminous efficiency occurs at a high frequency up to 200 kHz, originating from a self-erasing discharge and the space-charge behavior under high sustaining frequency conditions. Thus, based on an analysis of the failure mode of a wide-gap discharge, a new sustain waveform is proposed to improve the luminous efficiency at a high operating frequency. As a result of adopting the proposed sustain waveform, a luminous efficiency of 2.4 lm/W is obtained at a sustain voltage of 170 V in a 42-in high-definition wide-gap PDP.
BibTeX
@article{kim2008new,
  author = {Hyun Kim and Heung‐Sik Tae},
  title = {{New Sustain Waveform for Improving Luminous Efficiency in Wide-Gap Plasma-Display Panel}},
  journal = {IEEE Transactions on Electron Devices},
  year = {2008},
  doi = {10.1109/ted.2008.919387},
}

Loading related content...