Near field placement of error sensors in an active noise control application of axial cooling fans using flow visualization techniques
Abstract
The use of error sensors in the near field of an axial fan can be used to achieve global attenuation of the blade passage frequency and its harmonics. The pressure field produced by the minimized sound power radiation of the fan and control source configuration dictates possible locations of the error sensors by creating pressure nulls in the near field. By minimizing pressure at these locations, the minimized sound power field can be reproduced. Near field locations can be further investigated using qualitative flow visualization techniques including smoke visualization and quantitative particle image velocimetry (PIV). Analysis of the flow field will help to understand the presence of turbulent flow at the error sensors which can be a cause of a decreased signal to noise ratio. Optimal locations as well as mounting techniques for the error sensors will be discussed based on the flow field analysis. The effects of active noise control on the flow field produced by the fan will also be discussed.
BibTeX
@article{duke2007near,
author = {Connor R. Duke and Scott L. Thomson and Scott D. Sommerfeldt and Kent L. Gee and Cole L. Duke and David Krueger},
title = {{Near field placement of error sensors in an active noise control application of axial cooling fans using flow visualization techniques}},
journal = {The Journal of the Acoustical Society of America},
year = {2007},
doi = {10.1121/1.4782343},