NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Natural Gastrointestinal Stable Pea Albumin Nanomicelles for Capsaicin Delivery and Their Effects for Enhanced Mucus Permeability at Small Intestine

Yiming Li, Mengqi Mao, Xin Yuan, Jiajia Zhao, Lingjun Ma, Fang Chen, Xiaojun Liao, Xiao Hu, Junfu JiBiomaterials 2024

TL;DR

Researchers have developed novel pea albumin nanomicelles (PANs) that are stable in the harsh gastrointestinal environment and can effectively penetrate the intestinal mucus barrier. These PANs successfully delivered capsaicin (CAP), a hydrophobic drug, demonstrating improved absorption and bioavailability, paving the way for more effective oral delivery of challenging bioactive compounds.

What Problem Does This Paper Address?

Delivering hydrophobic drugs and bioactive compounds orally faces significant hurdles. The gastrointestinal tract is a hostile environment, with varying pH levels and digestive enzymes that can degrade nanodelivery systems before they reach their target. Furthermore, the intestinal mucus layer acts as a physical barrier, preventing larger nanocarriers from reaching the intestinal epithelial cells for absorption. Existing nanodelivery systems often struggle with one or both of these challenges, limiting their oral efficacy. This paper addresses the need for nanocarriers that are both stable in the gastrointestinal tract and capable of efficiently traversing the mucus layer to enhance oral drug absorption.

Methods

The study employed a multi-pronged approach to develop and evaluate the pea albumin nanomicelles (PANs):

  • Nanomicelle Fabrication: Pea albumin isolate (PAI) was first subjected to pre-enzymatic hydrolysis using trypsin. This process generated amphiphilic peptides. These peptides were then self-assembled into nanomicelles through a pH-shifting method. Capsaicin (CAP) was loaded into these nanomicelles.
  • Characterization: The physical and chemical properties of the PAI and PAN nanomicelles were thoroughly characterized. This included measuring particle size and polydispersity index (PDI) using dynamic light scattering, determining critical micelle concentration (CMC) using a fluorescence spectrophotometer, and analyzing surface and interfacial tension with a contact angle meter. Secondary structure changes were assessed using circular dichroism (CD) spectroscopy.
  • Gastrointestinal Stability: In vitro simulated digestion models (gastric and intestinal fluids) were used to evaluate the stability of the nanomicelles and their ability to retain encapsulated CAP.
  • Mucus Permeability: The ability of the nanomicelles to penetrate the intestinal mucus barrier was assessed using a Transwell permeable support system with purified porcine intestinal mucus.
  • Nanomicelle Movement in Mucus: Multiple particle tracking (MPT) technology was employed to visualize and quantify the movement and diffusion of fluorescently labeled nanomicelles within intestinal mucus.
  • Cellular Uptake and Transport: Caco-2 cell monolayers were used to study the cellular uptake mechanisms (endocytosis pathways) and intracellular transport of the nanomicelles. This involved using various endocytosis inhibitors and tracking the movement of nanomicelles through cellular compartments.
  • Transcellular Transport and P-gp Efflux: The ability of nanomicelles to cross the intestinal epithelial barrier (transepithelial transport) was evaluated using Caco-2 cell monolayers. The study also investigated whether the nanomicelles could overcome the P-glycoprotein (P-gp) efflux pump, which actively expels drugs from cells.
  • Intestinal Permeability: Ex vivo studies using rat intestinal segments were conducted to assess the permeability of the nanomicelles across different parts of the small intestine.

Datasets

Not discussed in the paper.

Key Insights and Ideas

  • Enzymatic Hydrolysis is Key: Partially hydrolyzing pea albumin isolate (PAI) with trypsin was crucial for creating amphiphilic peptides that could self-assemble into stable, small nanomicelles. This process exposed hydrophobic groups, enhancing their ability to interact with and encapsulate hydrophobic drugs like CAP.
  • Small Size Matters for Mucus Penetration: The significantly smaller particle size of PAN (36.42 nm) compared to PAI (101.63 nm) was a critical factor in its enhanced mucus permeability. Smaller particles can navigate the mucus mesh more effectively.
  • Hydrophilic Surface for Mucus Evasion: PANs possess a negatively charged and hydrophilic surface, which helps them avoid electrostatic and hydrophobic interactions with the mucus, facilitating easier penetration.
  • Overcoming P-gp Efflux: The nanomicelles demonstrated an ability to bypass the P-gp efflux pump, a major challenge for oral drug delivery. This is attributed to their size and the encapsulation of CAP within the hydrophobic core, preventing direct interaction with P-gp.
  • Enhanced Cellular Uptake Pathways: PANs are taken up by Caco-2 cells via energy-dependent active transport mechanisms (macropinocytosis, caveolae, and clathrin-mediated endocytosis), which are more efficient than the passive transport of free CAP.

Key Results

  • Small and Stable Nanomicelles: PANs were successfully fabricated with a small particle size (36.42 nm) and a narrow size distribution (PDI < 0.3), exhibiting superior intestinal stability with 40% higher CAP retention compared to PAI during simulated digestion.
  • Improved Mucus Permeability: PAN significantly increased CAP's mucus permeability by 2.5 times, demonstrating an excellent ability to overcome the mucus barrier.
  • Enhanced Cellular Uptake and Transport: PAN enhanced the cellular uptake and transcellular transport of CAP in Caco-2 cells, involving ER/Golgi and Golgi/plasma membrane pathways.
  • Superior Intestinal Permeability: In ex vivo studies, PAN significantly improved CAP permeability in the ileum, with Papp values 3.4 and 4.92 times higher than free CAP for PAI-CAP and PAN-CAP, respectively.
  • High Loading Capacity: PAN achieved a high loading capacity for CAP (20.02 µg/mg).

Limitations and Future Work

  • Storage Stability: While PAN-CAP showed good stability, its particle size increased significantly at 28 days of storage, suggesting potential aggregation over longer periods. PAI-CAP, however, remained stable for 28 days.
  • In Vivo Studies: The study primarily relied on in vitro and ex vivo models. Future work should involve in vivo studies to confirm the efficacy and safety of PANs in a living organism.
  • Broader Drug Applicability: While CAP was used as a model, further research is needed to explore the applicability of PANs for delivering a wider range of hydrophobic bioactive substances.
  • Optimization of Hydrolysis: Further optimization of the enzymatic hydrolysis process could potentially lead to even more stable and efficient nanocarriers.

Summary updated

BibTeX
@inproceedings{li2024natural,
  author = {Yiming Li and Mengqi Mao and Xin Yuan and Jiajia Zhao and Lingjun Ma and Fang Chen and Xiaojun Liao and Xiao Hu and Junfu Ji},
  title = {{Natural Gastrointestinal Stable Pea Albumin Nanomicelles for Capsaicin Delivery and Their Effects for Enhanced Mucus Permeability at Small Intestine}},
  booktitle = {Biomaterials},
  year = {2024},
  doi = {10.34133/bmr.0065},
}
Figure