Naked-eye ghost imaging via photoelectric feedback

Gao Wang, Huaibin Zheng, Zhiguo Tang, Yuchen He, Yu Zhou, Hui Chen, Jianbin Liu, Yuan Yuan, Fuli Li, Zhuo XuChinese 2019 · arXiv

Abstract

Based on optical correlations, ghost imaging is usually reconstructed by computer algorithm from the acquired data. We here proposed an alternatively high contrast naked-eye ghost imaging scheme which avoids computer algorithm processing. Instead, the proposed scheme uses a photoelectric feedback loop to realize the multiplication process of traditional ghost imaging. Meanwhile, it exploits the vision persistence effect to implement integral process and to generate negative images observed by naked eyes. To realize high contrast naked-eye ghost imaging, a special pattern-scanning architecture on a low-speed light-modulation mask is designed, which enables high-resolution imaging with lower-order Hadamard vectors and boosts the imaging speed as well. Moreover, two kinds of feedback circuits, the digital circuit and the analog circuit, are presented respectively, which can achieve high-speed feedback operation on the light intensity. With this approach, we demonstrate high-contrast real-time imaging for moving objects.

Introduction

Traditional ghost imaging (GI) is a technique where an image is reconstructed by correlating two light beams: a "signal" beam that interacts with an object but lacks spatial resolution (collected by a single-pixel "bucket" detector), and a "reference" beam that contains known spatial patterns but never interacts with the object. Historically, the correlation process—multiplying the bucket signal by the reference pattern and integrating over thousands of frames—has been a computational bottleneck, preventing true real-time, direct visualization.

This research introduces a "naked-eye" GI system that bypasses digital reconstruction entirely. By shifting the processing from a CPU to the physical hardware through a photoelectric feedback loop and utilizing the human eye's natural persistence of vision, the system enables direct observation of high-contrast images.

System Methodology

The core of the proposed system is the replacement of digital algorithms with physical mechanisms.

Photoelectric Feedback Loop

In this setup, the output from the bucket detector is fed directly back into the laser driver. This creates a negative feedback loop: when the bucket detector receives a high intensity (indicating a strong correlation between the pattern and the object's transparent regions), the feedback loop immediately reduces the laser's intensity. This physical interaction performs the "multiplication" step of the GI algorithm in real-time.

Schematic of the experimental setup showing the negative feedback loop and the human observer.

Persistence of Vision

The "integration" step of GI is handled biologically. Human vision retains stimuli for approximately 0.1 to 0.2 seconds. By projecting high-speed flickering patterns onto a screen, the human eye naturally averages these signals, effectively performing the mathematical integration required to form a coherent image.

Pattern Scanning Architecture

To achieve high resolution without excessive data requirements, the researchers developed a specialized pattern-scanning architecture. They utilized low-order Hadamard vectors and divided the imaging area into discrete blocks. This approach significantly boosts imaging speed and contrast while maintaining lower hardware complexity.

The block-based pattern-scanning architecture designed to enhance imaging speed and resolution.

Feedback Circuit Implementation

Two types of feedback circuits were evaluated:

  1. Digital Circuit: Utilizes TTL signals for high stability and noise suppression.
  2. Analog Circuit: Designed for high-speed operation, treating the feedback loop as a form of analog computation that solves the correlation equation through steady-state physics.

Results and Discussion

The system successfully produced clear, high-contrast negative images of various test objects (stencils of letters like "X", "J", "T", and "U") at a resolution of $35 \times 35$ pixels. Because the feedback is negative, transparent areas of the object appear dark, while opaque areas appear bright.

A key advantage of this approach is inherent noise suppression. The negative feedback loop stabilizes the output by compensating for ambient light spikes detected by the bucket sensor. Furthermore, the system is fast enough to image moving objects, overcoming a major limitation of traditional computational GI.

Conclusion

The "naked-eye" ghost imaging scheme demonstrates that complex computational tasks can be offloaded to physical and biological systems. While currently producing negative images, the technique offers a path toward real-time visualization in fields where digital processing is burdensome. Future applications could extend to X-ray imaging, LIDAR, and electron microscopy, where direct human interaction with the imaging data is highly beneficial.

Summary updated

Abstract

A new architecture, naked-eye ghost imaging via photoelectric feedback, is developed that avoids computer algorithm processing. Instead, the proposed scheme uses a photoelectric feedback loop to first realize the correlation (multiplication) process of the traditional ghost imaging system. Then, the vision persistence effect of the naked eye is exploited to implement the integral process and to generate negative images. Two kinds of feedback circuits, the digital circuit and the analog circuit, are presented that can achieve a feedback operation. Based on this design, high-contrast real-time imaging of moving objects is obtained via a special pattern-scanning architecture on a low-speed light-modulation mask.