Abstract
In this paper, a numerical model of gas flow, heat transfer, mass transfer and electrochemical reaction multi-physics field coupling of a planar SOFC is established and solved. According to the calculation results, the distribution of velocity, temperature and concentration inside the SOFC cell is analyzed. The influence of cathode inlet flow rate, porosity, rib width and other parameters on the performance of SOFC is also discussed. The results show that within a certain range, increasing the cathode inlet flow rate can significantly increase the average current density of the cell. Increasing the porosity of the electrode can improve the gas diffusion of the porous electrode, thereby increasing the rate of the electrochemical reaction. Increasing the width of the ribs will result in a significant decrease in cell performance. Therefore, the rib width should be reduced as much as possible within the allowable range to optimize the working performance of the cell.
Introduction
Solid Oxide Fuel Cells (SOFCs) are highly efficient, fuel-flexible energy conversion devices. However, optimizing their performance is challenging due to the simultaneous occurrence of complex processes such as gas flow, heat conduction, ion transport, and chemical reactions. Experimental testing often treats the cell as a "black box," making it difficult to observe internal distributions of temperature or gas concentration. This study presents a comprehensive 3D multiphysics model to bridge this gap, coupling fluid dynamics, heat transfer, and electrochemical reactions to provide a detailed internal view of a planar SOFC.
Methodology
The researchers established a 3D numerical model of a planar SOFC using a counter-flow configuration. The model integrates four key physical domains:
- Electrochemical Model: Based on the Nernst equation, accounting for activation, concentration, and ohmic polarization losses.
- Mass Transport: Utilizes the Maxwell-Stefan model for gas species diffusion through porous electrodes.
- Momentum Transport: Employs Navier-Stokes equations for gas channels and the Darcy-Brinkman equation for porous structures.
- Heat Transport: Accounts for conduction and convection under local thermal equilibrium.
Model Validation
The model was validated against experimental data from Yakabe et al. (2001). The predicted voltage-current (V-I) curves showed high fidelity, with a maximum relative error of less than 10%, confirming the model's reliability for parameter studies.
Results and Discussion
Thermal and Flow Characteristics
The simulation reveals a "thermal sweet spot" in the counter-flow setup. The highest temperatures (~1110 K) occur in the center of the cell where incoming cool gases exchange heat with hot outgoing gases from the opposite channel.
Geometric and Operational Impacts
- Rib Width: The interconnector ribs significantly impede gas diffusion. Increasing rib width from 0.5 mm to 1.5 mm caused average current density to drop from ~3800 A/m² to ~2600 A/m² due to oxygen depletion and longer electronic paths.
- Porosity: Increasing electrode porosity from 0.2 to 0.6 improved current density from ~2900 A/m² to ~3250 A/m², highlighting the importance of electrode "breathability."
- Inlet Temperature: Performance is highly sensitive to temperature; a 400 K increase in inlet temperature led to a massive jump in current density (from ~500 A/m² to ~6500 A/m²).
- Flow Rate: Increasing the cathode air flow rate boosts performance initially, but the benefits plateau once the electrochemical reaction is no longer reactant-limited.
Conclusion
This study demonstrates that optimizing physical geometry—specifically narrowing interconnector ribs and increasing electrode porosity—is as critical as managing operational parameters like flow rates and temperatures. While reducing rib width improves performance, structural integrity and electrical contact must be maintained. Future work will explore different flow configurations and long-term degradation effects.
Summary updated