Abstract
We use coded apertures and multiple views to create a compressive coherent scatter computed tomography (CSCT) system. Compared with other CSCT systems, we reduce object dose and scan time. Previous work on coded aperture tomography resulted in a resolution anisotropy that caused poor or unusable momentum transfer resolution in certain cases. Complimentary and multiple views resolve the resolution issues, while still providing the ability to perform snapshot tomography by adding sources and detectors.
BibTeX
@inproceedings{holmgren2016multi,
author = {Andrew D. Holmgren and Ikenna Odinaka and Joel A. Greenberg and David J. Brady},
title = {{Multi-view coded aperture coherent scatter tomography}},
booktitle = {Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE},
year = {2016},