Multi-institutional grading of Barrett's esophagus dysplasia without stain normalization using a pathology foundation model and multiple instance learning

Amirali Khosravi, Jaidip M. Jagtap, D. Chamil Codipilly, Catherine E. Hagen, Jason T. Lewis, Rickey E. Carter, Shahriar Faghani, Vani J. A. Konda, Fouad Otaki, Shajan Peter, Nicholas Shaheen, Sachin Wani, Prasad G. Iyer, Bradley J. EricksonarXiv 2026

TL;DR

Researchers have developed a deep learning system that accurately grades Barrett’s esophagus dysplasia across multiple medical institutions without requiring site-specific "stain normalization." By combining a pathology-specific foundation model with multiple instance learning, the system achieves expert-level consensus and high sensitivity, offering a scalable path for AI-assisted cancer screening.

What Problem Does This Paper Address?

Barrett’s esophagus (BE) is a condition where the lining of the esophagus changes, significantly increasing the risk of esophageal cancer. To manage this risk, pathologists "grade" tissue samples into three categories: non-dysplastic (NDBE), low-grade dysplasia (LGD), and high-grade dysplasia (HGD).

The problem is twofold. First, humans aren't great at being consistent; there is substantial inter-observer variability, especially for LGD, which can lead to over-treatment or missed cancers. Second, existing AI models are often "brittle." Because different labs use different chemicals and scanners, the resulting digital slides look different. Most AI systems require complex "stain normalization" to handle these variations, making them difficult to deploy across different hospitals.

Methods

The authors proposed a two-stage deep learning framework that prioritizes robustness and interpretability:

  1. Stage 1: Patch-Level Classification: The system breaks down massive Whole Slide Images (WSIs) into smaller patches. It uses Midnight-12k, a pathology foundation model (a Vision Transformer pre-trained on 12,000 slides), to extract features. Because this foundation model was trained with heavy color and texture augmentations, it is naturally resistant to staining variations. Four small neural networks then identify which patches contain relevant tissue (NDBE, LGD, or HGD).
  2. Stage 2: Slide-Level Classification (AttriMIL): The system uses an "Attribute-aware Multiple Instance Learning" (AttriMIL) architecture. It samples up to 1,000 of the most informative patches and learns to assign "attention" to them. This mimics a pathologist's workflow: scanning a slide and focusing on the most suspicious areas to make a final diagnosis.
The two-stage deep learning framework for grading Barrett’s esophagus dysplasia.

Datasets

The study utilized a retrospective multi-institutional dataset:

  • Total Slides: 969 H&E-stained slides from 961 patients.
  • Institutions: Mayo Clinic (the primary source for training annotations), Baylor University Medical Center, Oregon Health & Science University (OHSU), and the University of Alabama at Birmingham (UAB).
  • Ground Truth: Established by a consensus of two expert gastrointestinal pathologists.

Key Insights and Ideas

  • Foundation Models Eliminate Preprocessing: The most significant finding is that foundation models can bypass the need for "stain normalization." The model performed consistently across four different institutions despite the lack of site-specific tuning.
  • Safety-First Error Profile: In clinical settings, some mistakes are worse than others. The model never misclassified a high-grade dysplasia (HGD) case as non-dysplastic (NDBE). Most errors occurred between adjacent grades (e.g., LGD vs. HGD), which is a much safer "failure mode" for patient management.
  • Data Efficiency: While the model was trained on detailed patch-level annotations from only one site (Mayo Clinic), it generalized perfectly to the other three sites using only slide-level labels. This suggests that AI for pathology can be developed with much less manual labeling than previously thought.

Key Results

The system demonstrated strong discriminative performance on a held-out test set of 130 slides:

  • Macro-averaged AUC: 0.96, indicating excellent ability to distinguish between all three classes.
  • Dysplasia Detection: For the binary task of "Dysplasia vs. No Dysplasia," the model achieved 98% sensitivity and 81% specificity.
  • Expert Agreement: The model achieved a quadratic-weighted $\kappa$ of 0.83, signifying "strong" agreement with expert consensus.
  • Clinical Utility: The negative likelihood ratio was 0.030. In practice, this means a "negative" result from the AI reduces the probability of dysplasia from a typical 15% prevalence to just 0.5%, effectively ruling it out.
Detailed performance metrics across different dysplasia classes.

Limitations and Future Work

Despite the impressive results, the authors note several areas for improvement:

  • Retrospective Nature: The study used existing data; a prospective trial in a real-world clinical setting is needed to confirm these benefits.
  • Class Distribution: The test set was relatively balanced, whereas in real-world screening, the vast majority of cases are non-dysplastic. This could affect the "positive predictive value" in practice.
  • Longitudinal Outcomes: The study measures how well the AI agrees with pathologists today, but the ultimate goal is predicting which patients will actually develop cancer years down the line. Future work will require long-term patient follow-up data.

Summary updated

Abstract

Barrett's esophagus dysplasia grading suffers substantial inter-observer variability, particularly for low-grade dysplasia, complicating clinical decision-making. We conducted a retrospective multi-institutional diagnostic accuracy study of a foundation model-based deep learning system for dysplasia grading, using 969 H\&E-stained whole slide images from four institutions. Patch-level classifiers trained on expert annotations identified diagnostically relevant regions, followed by attribute-aware multiple instance learning for slide-level classification as non-dysplastic Barrett's esophagus (NDBE), low-grade dysplasia, or high-grade dysplasia. On a held-out test set (n = 130), macro-averaged AUC was 0.96 (95\% CI 0.93--0.98). For binary dysplasia detection, sensitivity was 98\% (80/82) and specificity 81\% (39/48), with a negative likelihood ratio of 0.030 and quadratic-weighted \kap{} of 0.83 against expert consensus. No high-grade dysplasia case was misclassified as NDBE. Performance was consistent across institutions without stain normalization, indicating that stain-robust foundation-model representations may remove the site-specific preprocessing that has constrained prior systems to institution-specific deployment.
BibTeX
@misc{khosravi2026multi,
  author = {Amirali Khosravi and Jaidip M. Jagtap and D. Chamil Codipilly and Catherine E. Hagen and Jason T. Lewis and Rickey E. Carter and Shahriar Faghani and Vani J. A. Konda and Fouad Otaki and Shajan Peter and Nicholas Shaheen and Sachin Wani and Prasad G. Iyer and Bradley J. Erickson},
  title = {{Multi-institutional grading of Barrett's esophagus dysplasia without stain normalization using a pathology foundation model and multiple instance learning}},
  year = {2026},
  eprint = {2611.26562},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.26562},
}
Figure