NeurIPS 2026Coming to NeurIPS in Sydney?Explore papers, orals & directions

MTLiquid: Enabling Efficient Multi-Task Learning using Liquid Neural Networks for Lightweight Healthcare Monitoring Systems

Rachmad Vidya Wicaksana Putra, Fahad Abdul Rauf, Muhammad ShafiquearXiv 2026

TL;DR

MTLiquid is a new multi-task learning framework that uses Liquid Neural Networks (specifically Closed-form Continuous-time networks, or CfCs) to monitor patient health. By sharing a single "continuous-time" backbone across multiple medical tasks, it achieves state-of-the-art accuracy in predicting mortality and sepsis while reducing memory requirements by up to 94% compared to traditional models.

What Problem Does This Paper Address?

In an Intensive Care Unit (ICU), physiological data like heart rate or blood pressure isn't collected on a perfectly regular heartbeat. It’s "irregularly sampled"—sometimes you get a reading every minute, sometimes every hour.

Traditional AI models, like Recurrent Neural Networks (RNNs), struggle here because they assume data arrives in fixed discrete steps. While "Liquid" Neural Networks (LNNs) were designed to handle this continuous flow of time, they are typically used for just one task at a time. In a real hospital setting, we need to monitor for multiple risks simultaneously (e.g., "Is this patient at risk of sepsis?" AND "What is their mortality risk?").

Running separate models for every task is a massive drain on memory and power, which is a dealbreaker for the wearable devices and lightweight monitoring systems the healthcare industry wants to build.

Methods

The authors propose MTLiquid, which leverages Closed-form Continuous-time (CfC) networks. Unlike original Liquid networks that require slow, complex math (ODE solvers) to calculate how a neuron changes over time, CfCs use a mathematical shortcut that makes them much faster and more efficient.

The Architecture

As shown in Figure 1, the model uses a "shared backbone" approach:

  1. Task-Specific Input Heads: Raw data from different tasks (which might have different numbers of variables) are projected into a common 64-dimensional space.
  2. Shared CfC Backbone: A single recurrent engine processes this data. Crucially, it takes the elapsed time ($\Delta t$) between readings as an explicit input, allowing the network's "liquid" gates to adapt their behavior based on how much time has passed.
  3. Task-Specific Output Heads: The final state of the backbone is sent to separate linear layers to produce predictions for each specific task.
Figure 1: Multi-task architecture in MTLiquid based on the CfC concept. Task-specific inputs are projected to a common 64-dimensional space, concatenated with h(t −1), and passed through a shared backbone. Candidate and time-gate branches (gated by σ over ∆tt) update the hidden state, which feeds task-specific linear heads.

The Training Strategy

To make multi-tasking work, the authors introduced two clever tricks:

  • Uncertainty-based Loss Weighting: Instead of manually guessing which task is "harder," the model automatically learns how to weight the importance of each task's error during training.
  • Capped-Cycling: Medical datasets are often imbalanced (e.g., one dataset might be much larger than another). MTLiquid uses a scheduling policy that repeats smaller datasets just enough to keep the model learning without "memorizing" (overfitting) them.

Datasets

The model was evaluated on two major PhysioNet benchmarks:

  • P12 (PhysioNet 2012): Focused on predicting in-hospital mortality for ICU patients based on 42 variables over their first 48 hours.
  • P19 (PhysioNet 2019): Focused on the early detection of sepsis using 40 physiological channels.

Key Insights and Ideas

  • Time is a First-Class Citizen: By treating the interval between measurements ($\Delta t$) as a core input, the model doesn't need to "guess" what happened during missing data gaps. The "liquid" dynamics naturally evolve the hidden state over time.
  • Shared Dynamics Work: The most surprising finding is that a single set of neural dynamics can effectively model two very different medical conditions. This suggests that the underlying "rhythm" of physiological decay and response is consistent enough to be shared.
  • Efficiency is the "Aha" Moment: Because the backbone is shared, adding a new task is incredibly "cheap" in terms of parameters. You only need to add a small input projection and a tiny output head.

Key Results

MTLiquid proves that you don't have to sacrifice accuracy for efficiency.

  • Accuracy: It achieved an AUROC of 0.84 for mortality (P12) and 0.94 for sepsis (P19). This is virtually identical to the performance of much larger, single-task models.
  • Memory Savings: Compared to running two separate CfC models, MTLiquid reduced the parameter count by 44.1%. Compared to traditional LSTM models, the savings were a staggering 94.1% (see Figure 3).
  • Power Consumption: In multi-task settings, MTLiquid consumed 43.1% less power than LSTMs and 36.9% less than RNNs, making it highly suitable for battery-powered medical wearables.
Table 1: Single-task versus multi-task performance across architectures. For multi-task, each row is the same shared model (one architecture, one parameter count). CfC matches or exceeds LSTM/RNN at a fraction of the parameters and model size.

The ablation study in Figure 2 further highlights that the combination of forward-fill imputation and the capped-cycling strategy was essential to reaching these high performance levels.

Table 2: Ablation progression for the CfC multi-task backbone. Each stage is cumulative over the previous one unless noted.

Limitations and Future Work

While impressive, the paper focuses on two specific classification tasks. The authors do not discuss how the system would scale if we moved from two tasks to twenty. Additionally, while the power and memory savings are calculated, the paper does not demonstrate the model running on actual wearable hardware (like an ARM-based microcontroller), which would be the ultimate test for "lightweight" claims.

Future work could explore expanding this to regression tasks (like predicting specific lab values) or incorporating more diverse data types like medical imaging or notes.

Summary updated

Abstract

Continuous-time sensing and monitoring with timely and accurate decision-making are critical for many real-world applications. In healthcare monitoring systems, physiological signals are often available or sampled at irregular time intervals, hence requiring continuous-time processing to provide accurate prediction. Moreover, such systems often need to solve multiple detection/prediction tasks to provide a comprehensive patient review from different physiological aspects for more accurate decision-making. To solve this, continuous-time neural networks (CTNNs) can be employed. However, state-of-the-art works typically solve only one task at each network, thereby limiting their efficiency gains. To address this limitation, we propose MTLiquid, a novel methodology to enable efficient multi-task learning in continuous-time processing for healthcare monitoring systems through effective network design and training strategy. MTLiquid employs: (1) multiple input and output heads to accommodate different tasks, while sharing the same backbone network across tasks; as well as (2) an effective training strategy that leverages a loss-weighting technique to balance learning updates across different tasks and a proportional data presentation technique to address imbalanced dataset sizes. Experimental results for mortality prediction (P12) and sepsis early detection (P19) tasks for ICU patients show that, MTLiquid achieves strong performance (AUROC: 0.84 for P12 and 0.94 for P19) comparable to the state-of-the-art single-task learning in both continuous-time networks (AUROC: 0.84 for P12 and 0.95 for P19) and discrete-time networks (AUROC: 0.79-0.82 for P12 and 0.92-0.94 for P19), while incurring significantly smaller memory cost by 44%-94%. These results highlight the potential of our MTLiquid methodology to enable lightweight continuous-time healthcare monitoring systems for better decision-making.

Empirical ResultsBrowse all benchmarks →

BenchmarkMethodMetricScoreProtocol / Evidence
PhysioNet P12 + P19 (two-task model footprint)MTLiquid (one shared multi-task model)Model size0.40 MBmodel-configuration=one shared multi-task MTLiquid model
Source quote
L361: The two independent single-task CfC models together require 188{,}292 parameters (0.71~MB combined: 0.35~MB for P12, 0.36~MB for P19), while our multi-task model (MTLiquid) requires 105{,}350 parameters (0.40~MB), a 44.1% reduction in parameter count and 43.7% reduction in size.
Reported baseline / comparator measurements (1)
BenchmarkMethodMetricScoreProtocol / Evidence
PhysioNet P12 + P19 (combined two-task model footprint)Two independent single-task CfC models (P12 and P19) baselineCombined model size0.71 MBscope=combined footprint · model-configuration=two independent single-task CfC models
Source quote
L361: The two independent single-task CfC models together require 188{,}292 parameters (0.71~MB combined: 0.35~MB for P12, 0.36~MB for P19), while our multi-task model (MTLiquid) requires 105{,}350 parameters (0.40~MB), a 44.1% reduction in parameter count and 43.7% reduction in size.
BibTeX
@misc{putra2026mtliquid,
  author = {Rachmad Vidya Wicaksana Putra and Fahad Abdul Rauf and Muhammad Shafique},
  title = {{MTLiquid: Enabling Efficient Multi-Task Learning using Liquid Neural Networks for Lightweight Healthcare Monitoring Systems}},
  year = {2026},
  eprint = {2609.33232},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.33232},
}
Figure