MRI-Driven Dual-Energy CT Synthesis via Conditional Denoising Diffusion Probabilistic Models for MRI-only Radiotherapy and Protontherapy

Juan Manuel Molina-Maza Chih-Wei Chang, David Viar-Hernandez, Zach Eidex, Mojtaba Safari, Shaoyan Pan, Juan Maria Perez-Moreno, Norberto Malpica, Angel Torrado-Carvajal, Borja Rodriguez-Vila, Xiaofeng YangarXiv 2026

Imagine you’re a radiation oncologist planning a high-stakes mission. You need to hit a tumor with a beam of protons—a "subatomic bullet"—with millimeter precision. To do this, you need two things: a clear map of the "terrain" (soft tissues) and a precise understanding of the "density" of that terrain (how much the tissue slows down the protons).

Magnetic Resonance Imaging (MRI) gives you a beautiful, high-contrast map of the soft tissues without any harmful radiation. But MRI is "blind" to density; it sees hydrogen atoms, not the electron density that stops a proton. For that, you need a Computed Tomography (CT) scan, which uses ionizing radiation. Dual-Energy CT (DECT) is the gold standard here, providing a detailed "material signature" of the body, but it exposes the patient to even more radiation.

This paper asks: Can we use AI to "hallucinate" a high-fidelity Dual-Energy CT scan using only a safe, radiation-free MRI?

TL;DR

Researchers developed a generative AI model called a Denoising Diffusion Probabilistic Model (DDPM) that transforms a single MRI scan into synthetic high- and low-energy CT volumes. This "MRI-only" workflow provides the precision required for proton therapy dose calculations while sparing patients from the additional ionizing radiation of a traditional CT scan.

What Problem Does This Paper Address?

In modern radiotherapy, and especially in Proton Therapy (PT), accuracy is everything. Protons have a unique property: they travel through tissue and dump most of their energy at a specific depth called the Bragg Peak. If your estimate of tissue density—known as the Stopping Power Ratio (SPR)—is off by even a tiny bit, that energy dump happens in the wrong place, potentially missing the tumor or frying a nearby vital organ.

Currently, clinicians often have to register (align) an MRI to a CT. This is tricky because patients move, and the two scans might not line up perfectly. An "MRI-only" workflow would eliminate this alignment error and reduce radiation exposure. However, standard AI methods (like GANs) often struggle to produce the subtle material differences needed for accurate SPR maps.

Methods

The authors turned to Denoising Diffusion Probabilistic Models (DDPM). Think of this like a master sculptor starting with a block of static (Gaussian noise) and slowly refining it into a detailed statue, guided by the "blueprint" of an MRI scan.

Figure 1: Visual representation of the diffusion process for both HECT (upper row) and LECT (lower row) volumes, showing the forward (red arrow) and reverse (blue arrow) diffusion phases. In the forward phase, a small amount of noise is iteratively added to each original volume until only Gaussian noise remains. During the reverse phase, our neural network progressively removes the noise at each timestep, learning to recover high-fidelity 3D volumes for both energy levels.

Key Innovations: * Multi-Decoder Framework: Instead of generating one image, the model has two "arms" (decoders) that simultaneously generate the high-energy and low-energy CT scans from the same MRI input. * SwinViT Backbone: They used a "Swin Transformer" architecture. Unlike traditional convolutional networks that look at small local patches, Transformers can look at the "big picture" (long-range dependencies), which helps in capturing complex anatomical textures. * Conditional Denoising: The MRI acts as a constant anchor, ensuring the generated CT doesn't just look "realistic" but is anatomically faithful to that specific patient.

Datasets

The study used a retrospective database of 53 head and neck cancer patients.

  • Each patient had same-day MRI and DECT scans.
  • The MRI (T1-weighted) was used as the input.
  • The DECT (120 kVp beam split into high and low energy) served as the "Ground Truth."
  • Data was split into training (70%), validation (10%), and testing (20%).

Key Insights and Ideas

  • Stability over Speed: While Generative Adversarial Networks (GANs) are fast, they are notoriously finicky and prone to "mode collapse" (where they just output the same generic image). Diffusion models are mathematically more stable and produce higher-fidelity results, even if they take longer to run.
  • The "Dual" Advantage: By generating two energy levels, the model allows physicists to perform "stoichiometric" calculations—essentially using the ratio between the two energies to identify exactly what a tissue is made of (bone vs. muscle vs. fat).
  • Texture Matters: The SwinViT architecture outperformed standard convolutional models (ResUNet), suggesting that global context is vital when trying to infer density from the hydrogen signals of an MRI.

Key Results

The DDPM approach consistently beat out the GAN baselines (Pix2Pix and CycleGAN) across the board:

  • Accuracy: The Mean Absolute Error (MAE) for the synthetic scans was roughly 36–43 Hounsfield Units (HU). For context, air is -1000 and bone is +1000, so this is a very small margin of error.
  • Visual Fidelity: The synthetic images preserved sharp bone edges and subtle soft-tissue boundaries that GANs often blurred.
  • Clinical Utility: Most importantly, the SPR maps (the density maps used for proton beams) derived from the AI scans were highly accurate, with errors staying within the acceptable clinical range for treatment planning.

Limitations and Future Work

  • The "Time Tax": Diffusion models are slow. Generating a volume took 240 seconds, compared to just 10 seconds for a GAN. While 4 minutes is fine for a planning session, it’s a hurdle for real-time applications.
  • Small Cohort: 53 patients is a great start, but AI needs thousands of examples to be truly robust across different hospitals and scanners.
  • Physics Integration: The model is currently "image-to-image." The authors suggest that future versions should incorporate "physics-informed" constraints—essentially teaching the AI the laws of radiation physics so it doesn't just guess the density, but calculates it.

Summary updated

Abstract

Magnetic resonance imaging (MRI) provides excellent soft-tissue contrast without ionizing radiation but lacks the electron-density information needed for radiotherapy dose calculation. Dual-energy computed tomography (DECT) improves tissue characterization and stopping-power ratio (SPR) estimation for proton therapy, but requires additional radiation exposure. We developed a denoising diffusion probabilistic model (DDPM) to synthesize high- and low-energy CT (sHECT and sLECT) simultaneously from a single MRI scan. Retrospective paired MRI-DECT data from patients receiving head-and-neck proton therapy were used to train and evaluate a multi-decoder DDPM with SwinViT or ResUNet denoisers. Performance was compared with Pix2PixGAN and CycleGAN using image-quality metrics, Hounsfield unit (HU) errors, anatomical profiles, and SPR maps and uncertainties. The DDPM outperformed both generative adversarial network baselines in visual fidelity and quantitative image quality. For sHECT and sLECT, respectively, mean absolute errors were 36.29 +/- 5.25 and 43.72 +/- 6.77 HU; peak signal-to-noise ratios were 27.44 +/- 1.06 and 26.26 +/- 0.98 dB; structural similarity indices were 0.89 +/- 0.02 and 0.87 +/- 0.03; and normalized cross-correlations were 0.95 +/- 0.01 and 0.94 +/- 0.01. The synthesized images preserved anatomical boundaries, while uncertainties in derived SPR maps remained within the expected acceptable range. MRI-based DECT synthesis using DDPM may provide tissue-specific information for proton therapy planning while reducing the need for radiation-based DECT acquisition.
BibTeX
@misc{chang2026mri,
  author = {Juan Manuel Molina-Maza Chih-Wei Chang and David Viar-Hernandez and Zach Eidex and Mojtaba Safari and Shaoyan Pan and Juan Maria Perez-Moreno and Norberto Malpica and Angel Torrado-Carvajal and Borja Rodriguez-Vila and Xiaofeng Yang},
  title = {{MRI-Driven Dual-Energy CT Synthesis via Conditional Denoising Diffusion Probabilistic Models for MRI-only Radiotherapy and Protontherapy}},
  year = {2026},
  eprint = {2611.28294},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.28294},
}
Figure