MP32-18 DEVICE-RELATED COMPLICATIONS DURING RENAL CRYOABLATION: INSIGHTS FROM THE MANUFACTURER AND USER FACILITY DEVICE EXPERIENCE (MAUDE) DATABASE
Abstract
You have accessJournal of UrologyCME1 May 2022MP32-18 DEVICE-RELATED COMPLICATIONS DURING RENAL CRYOABLATION: INSIGHTS FROM THE MANUFACTURER AND USER FACILITY DEVICE EXPERIENCE (MAUDE) DATABASE Srinath Kotamarti, Zoe Michael, David Silver, Ervin Teper, Alireza Aminsharifi, Thomas Polascik, and Ariel Schulman Srinath KotamartiSrinath Kotamarti More articles by this author , Zoe MichaelZoe Michael More articles by this author , David SilverDavid Silver More articles by this author , Ervin TeperErvin Teper More articles by this author , Alireza AminsharifiAlireza Aminsharifi More articles by this author , Thomas PolascikThomas Polascik More articles by this author , and Ariel SchulmanAriel Schulman More articles by this author View All Author Informationhttps://doi.org/10.1097/JU.0000000000002581.18AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: Cryoablation offers a treatment option ideally for renal masses <3 cm in well-selected candidates. However, little is known regarding device-related complications associated with the procedure. We provide an analysis of reports from the Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database. METHODS: Reports on renal cryoablation submitted to the MAUDE database from 2015 to 6/2021 were analyzed. Cases were examined to identify patient morbidity related to a potential device malfunction, as well as manufacturer assessment. Complications were graded based on an established MAUDE complication stratification. Fisher’s Exact test was utilized to analyze for associations between device-related adverse events and severity of post-treatment sequelae. RESULTS: A total of 239 unique cases were identified and tabulated (Table 1). Adverse events were related to issues with the needles/system, technical error, or patient/tumor complexity. There were 187 (78.6%) minor complications (MAUDE 1-2) and 52 (21.4%) major complications (MAUDE 3 to 4). The manufacturer performed formal device review in 164 (68.6%) cases, accepting responsibility in 41. All three reported patient deaths (MAUDE 4) appeared to be a consequence of poor baseline health. Major complications were seen in a higher proportion of non-device-related adverse events (23 of 27 cases, 85.2%) compared to device-related events (29 of 212 cases, 13.7%); these frequencies were significantly different on statistical analysis (p <0.001). CONCLUSIONS: While renal cryoablation is associated with low overall perioperative morbidity, there was a spectrum of device-related and procedural complications reported in recent years. Device-related adverse events were often associated with minor complications, and major complications were often seen in patients with comorbidities, more complex tumors, and after technical error. These findings highlight the need for standardized reporting of complications and optimized patient selection, particularly in regard to patient comorbidity and tumor characteristics, to ensure the best outcomes. Source of Funding: N/A © 2022 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 207Issue Supplement 5May 2022Page: e539 Advertisement Copyright & Permissions© 2022 by American Urological Association Education and Research, Inc.MetricsAuthor Information Srinath Kotamarti More articles by this author Zoe Michael More articles by this author David Silver More articles by this author Ervin Teper More articles by this author Alireza Aminsharifi More articles by this author Thomas Polascik More articles by this author Ariel Schulman More articles by this author Expand All Advertisement PDF downloadLoading ...
BibTeX
@article{kotamarti2022mp,
author = {Srinath Kotamarti and Zoe Michael and David Silver and Ervin Teper and Alireza Aminsharifi and Thomas J. Polascik and Ariel Schulman},
title = {{MP32-18 DEVICE-RELATED COMPLICATIONS DURING RENAL CRYOABLATION: INSIGHTS FROM THE MANUFACTURER AND USER FACILITY DEVICE EXPERIENCE (MAUDE) DATABASE}},
journal = {The Journal of Urology},
year = {2022},
doi = {10.1097/ju.0000000000002581.18},
}Ask Althea to put this paper to the test.
Loading related content...