Abstract
Molecularly imprinted polymers (MIPs) with high selectivity to ractopamine (RAC) were prepared by using RAC as template, acrylamide (AM) as monomer, and ethylene glycol dimethacrylate (EGDMA) as cross-linker. The effects of four porogens (methanol, acetonitrile, acetone, and chloroform-methanol) with triethylamine (30:1, v/v) on the recognition capability of MIPs to RAC and the morphological characteristics of the polymers were investigated. Orthogonal test was used to optimize the preparation of MIPs, and the optimal compositions were as follows: 1.0 mmol RAC, 4.0 mmol AM, 20.0 mmol EGDMA, 6.0 mL acetonitrile-triethylamine (30:1, v/v), and 50.0 mg azobisisobutyronitrile. A high performance liquid chromatographic method based on molecularly-imprinted solid-phase extraction (MISPE) was developed for the determination of ractopamine in feed samples. The limit of detection (LOD, S/N = 3) of ractopamine was 0.1 mg/kg. The linear range was 0.50-100 mg/L (r = 0.999 4). Mean recoveries of RAC spiked in 3 kinds of feed samples at 1.0, 10 and 100 mg/kg were above 80% with the relative standard deviations of less than 10%. The clean-up efficiency of MISPE was ideal for feed samples. The method is more sensitive and reproduciable than the standard analytical method for the determination of RAC in feed matrices.
Introduction
Ractopamine (RAC) is a $\beta$-agonist used to promote leanness in livestock. While permitted in some countries, it is strictly banned in China and the EU due to potential human health risks from residues in meat. Detecting RAC in animal feed is notoriously difficult because feed is a complex matrix packed with proteins, fats, and minerals that interfere with chemical analysis. Traditional extraction methods, such as C18 or Mixed-mode Cation Exchange, often lack the specificity to distinguish RAC from the background "noise" of the feed, leading to low recovery rates and unreliable results. This study aims to develop a Molecularly Imprinted Polymer (MIP) that specifically recognizes and captures RAC molecules, providing a cleaner and more sensitive detection method.
Materials and Methods
The researchers employed Molecularly Imprinted Polymers (MIPs) as a specialized filter. The process involves template assembly using RAC, polymerization with Acrylamide (AM) and EGDMA, and subsequent template removal to leave behind "molecular footprints" perfectly shaped for RAC molecules.
To optimize the polymer recipe, the team investigated the effects of different functional monomers (4-vinylpyridine (4-VP), 2-vinylpyridine (2-VP), and acrylamide (AM)) and four porogens (methanol, acetonitrile, acetone, and chloroform-methanol). An orthogonal test ($L_9(3^4)$) was used to refine the amounts of monomer, cross-linker, porogen, and initiator.
The final detection was performed using High-Performance Liquid Chromatography (HPLC) paired with a fluorescence detector (FLD). The method was validated using three types of real-world feed matrices: premix feed, feed additives, and compound feed, spiked with RAC at concentrations of 1.0, 10, and 100 mg/kg.
Results and Discussion
Optimization and Selectivity
The choice of porogen and monomer was critical for recognition capability. As shown in the experimental data, the mixture of acetonitrile and triethylamine (30:1) proved superior, particularly when paired with acrylamide (AM). The triethylamine was essential to increase the solubility of the RAC template, ensuring the formation of high-quality imprinted cavities. The optimized MIP showed high affinity for RAC and structurally similar $\beta$-agonists like clenbuterol and salbutamol, suggesting potential for multi-residue screening.
Analytical Performance
The developed MISPE-HPLC method demonstrated excellent sensitivity and accuracy:
- Sensitivity: The Limit of Detection (LOD) was 0.1 mg/kg.
- Accuracy: Recovery rates across all feed types were above 80%, with a Relative Standard Deviation (RSD) of less than 10%.
- Clean-up Efficiency: MISPE produced significantly cleaner chromatograms compared to standard national methods (GB/T 20189-2006), effectively removing matrix interferences.
- Reusability: The MISPE columns maintained performance for over 10 uses in pure water and at least 6 uses with complex feed extracts.
Conclusion
The molecularly-imprinted solid phase extraction method provides a highly selective and sensitive approach for determining ractopamine in animal feed. While "template bleeding" remains a minor concern for ultra-trace analysis, the method's superior clean-up efficiency and reproducibility make it an ideal candidate for regulatory monitoring. Future developments may focus on using "dummy templates" to eliminate leaching issues or adapting the technology for portable on-site testing.
Summary updated