Modified Non-Transposed Brachiobasilic Fistula is a Good Choice for Patients with Radial Artery Insufficiency in the Forearm

Yi Hou, Guozheng Feng, Yonghong Yan, Guocun HouAnnals 2020

Introduction

For patients with end-stage renal disease (ESRD), establishing reliable vascular access for hemodialysis is a critical "lifeline." While clinical guidelines generally recommend the wrist radiocephalic arteriovenous fistula (RCAVF) as the first choice, its success depends on adequate vessel diameter (typically >2.0 mm). In patients with "radial artery insufficiency"—where the forearm arteries are too small (e.g., <1.5 mm)—standard wrist fistulas often fail to mature. This paper presents a modified surgical technique, the Non-Transposed Brachio Cubital AVF (NT-BCAVF), designed to overcome these limitations by utilizing the elbow's vascular anatomy.

Surgical Methodology

The NT-BCAVF procedure employs several technical modifications to optimize hemodynamics and maximize usable vein length:

  1. Side-to-Side Anastomosis: A junction is created between the brachial artery and the median cubital vein, rather than a standard end-to-side connection.
  2. Mechanical Valve Disruption: To enable retrograde (backward) flow into the forearm cephalic vein, surgeons use a 5-French ureteral catheter to mechanically render venous valves incompetent.
  3. Strategic Ligation: The perforating vein, which connects superficial veins to deep veins, is ligated. This forces blood into the superficial cephalic and basilic veins, making them more accessible for dialysis needles.
  4. Anatomic Optimization: The anastomosis is positioned lower in the antecubital fossa to increase the available length of the arterialized vein for cannulation.

Case Study and Hemodynamic Results

The technique was applied to a 38-year-old female patient with ESRD and small radial arteries (<1.5 mm). Postoperative evaluation at four weeks using Doppler ultrasonography demonstrated exceptional results.

Anatomical diagram and Doppler ultrasound results showing high flow volumes in the proximal cephalic, basilic, and distal cephalic veins.

As shown in Figure 1, the modification achieved high flow rates across multiple venous segments:

  • Proximal Cephalic Vein: 2210 mL/min
  • Basilic Vein: 1512 mL/min
  • Distal Cephalic Vein (Retrograde): 687 mL/min

These flow rates significantly exceed the 600 mL/min threshold typically required for effective dialysis. Furthermore, ultrasound confirmed healthy vascular remodeling and the presence of spiral laminar flow, which is associated with better long-term fistula patency.

Discussion

The NT-BCAVF technique offers several advantages. By engineering retrograde flow, it effectively doubles the available surface area for dialysis needles. Unlike some other proximal modifications that involve ligating the proximal basilic vein, this approach preserves it as a "vascular resource" for future surgeries. Additionally, the superficial nature of the antecubital fossa makes the surgery less invasive than deeper transpositions.

Conclusion and Limitations

The modified NT-BCAVF is a promising alternative for patients with poor distal arterial supply. However, as this is a case report ($N=1$), the primary limitation is the small sample size. While the 4-week results are impressive, larger longitudinal studies are necessary to establish long-term patency rates and monitor for potential complications such as "steal syndrome" or venous hypertension.

Summary updated

BibTeX
@article{hou2020modified,
  author = {Yi Hou and Guozheng Feng and Yonghong Yan and Guocun Hou},
  title = {{Modified Non-Transposed Brachiobasilic Fistula is a Good Choice for Patients with Radial Artery Insufficiency in the Forearm}},
  journal = {Annals},
  year = {2020},
}
Figure