Microsphere-Based Microsensor for Miniature Motors' Vibration Measurement

Kaichuan Xu, Chunlei Jiang, Qilu Ban, Pan Dai, Yaqiang Fan, Shijie Yang, Yue Zhang, Jiacheng Wang, Yu Wang, Xiangfei Chen, Jie Zeng, Feng Wang2023 · DOI

TL;DR

This paper introduces a novel microsensor utilizing a microsphere and a stretched optical fiber to measure the axial and radial vibrations of miniature motor shafts (MMS) in confined spaces. By leveraging the photonic nanojet (PNJ) phenomenon for precise focusing and a Fabry-Perot interference mechanism, the sensor achieves high accuracy and simultaneous measurement of both vibration types, offering a compact and cost-effective solution for industrial applications.

What Problem Does This Paper Address?

Miniature motors are ubiquitous in modern technology, from aerospace to robotics. A critical parameter for their performance, condition monitoring, and fault diagnosis is the vibration of their shafts. However, measuring the vibrations of these tiny shafts, often with diameters in the sub-millimeter or even micron range, presents a significant challenge, especially in confined spaces. Existing vibration sensors, such as eddy current, capacitive, LVDT, LSMI, and DHI sensors, have limitations including susceptibility to electromagnetic interference, edge effects, wear, low accuracy due to speckle interference, or limited measurement ranges. Crucially, most conventional methods struggle to simultaneously measure both axial and radial vibrations of these miniature shafts in tight environments.

Methods

The core of the proposed microsensor is a combination of a stretched single-mode optical fiber and a 5 µm diameter microsphere. When light from the fiber is incident on the microsphere, it generates a photonic nanojet (PNJ). This phenomenon creates a highly focused light spot that is narrower than the diffraction limit, enabling precise illumination of the miniature motor shaft (MMS). The PNJ's focusing capability significantly enhances the intensity of scattered or reflected light from the MMS surface.

The vibration measurement itself relies on a Fabry-Perot (F-P) interference principle. Two F-P cavities are formed: one between the air end face of the microsphere and the radial position of the MMS (for radial vibration), and another between the air end face of a second microsphere and the axial position of the MMS (for axial vibration). As the MMS vibrates, the lengths of these cavities change, altering the phase difference between the reference and sensing light beams. This phase difference is then demodulated using the Multiple Hilbert Transform (MHT) algorithm to reconstruct the axial and radial displacements. The paper highlights that this setup allows for simultaneous measurement of both vibration types using a single light source.

Datasets

Not discussed in the paper. The experiments involved using a standard piezoelectric (PZT) oscillator as a calibrated vibration source and a miniature hollow-cup gear motor for real-world testing.

Key Insights and Ideas

  • PNJ for Precision Focusing: The use of a microsphere to generate a photonic nanojet is a key innovation. This allows for sub-diffraction-limit focusing, which is essential for accurately targeting and illuminating extremely small motor shafts.
  • Simultaneous Axial and Radial Measurement: The ability to measure both axial and radial vibrations concurrently with a single, compact sensor system is a significant advantage over many existing methods.
  • Compact and Integrated Design: The microsensor's small size (micrometer scale) and integration of fiber optics make it highly suitable for deployment in confined spaces where traditional sensors cannot fit.
  • Enhanced Signal-to-Noise Ratio: The PNJ's focusing capability amplifies the reflected light, leading to a higher signal-to-noise ratio and improved measurement accuracy.
  • Calibration and Validation: The rigorous calibration using a PZT with known displacement resolutions and comparison with a laser vibrometer provide strong evidence for the sensor's accuracy and linearity.

Key Results

  • High Accuracy: The microsensor demonstrated measurement errors of less than 1.5% when calibrated against a standard vibration source (PZT). The maximum absolute error was found to be less than 0.15 µm in specific tests.
  • Sensitivity: The sensor exhibits a high sensitivity of 0.7 mV/nm, making it capable of detecting small vibrations crucial for early fault detection.
  • Wide Dynamic Range: The sensor can measure vibrations ranging from 10 nm to 500 µm, covering a broad spectrum of potential motor shaft movements.
  • Frequency Response: The microsensor has a frequency response of 0.5 Hz to 100 kHz, which is sufficient for detecting both high-frequency running vibrations and low-frequency fault vibrations in miniature motors.
  • Comparative Performance: Experiments comparing the microsphere-based sensor with a simple fiber-optic sensor (without a microsphere) showed a significant degradation in signal quality (amplitude reduction by an order of magnitude, reduced signal-to-noise ratio, and severe distortion) when the microsphere was absent, underscoring its importance.

Limitations and Future Work

  • Surface Preparation: The paper emphasizes the importance of proper surface preparation (cleaning, smoothing, rust removal) of the MMS for accurate measurements. Irregular or contaminated surfaces can introduce errors.
  • Potential for Damage: While not explicitly stated as a limitation, the close proximity required for measurement implies a risk of damaging the microsphere or the motor shaft if not handled carefully, especially with small working distances.
  • Future Work: The authors suggest that the microsensor's miniaturization, ease of integration, and low cost make it suitable for further development in micromachining for even smaller sizes and applications in sensing in tighter spaces. The potential for vibration detection of micro-targets is also highlighted.

Summary updated

BibTeX
@misc{xu2023microsphere,
  author = {Kaichuan Xu and Chunlei Jiang and Qilu Ban and Pan Dai and Yaqiang Fan and Shijie Yang and Yue Zhang and Jiacheng Wang and Yu Wang and Xiangfei Chen and Jie Zeng and Feng Wang},
  title = {{Microsphere-Based Microsensor for Miniature Motors' Vibration Measurement}},
  year = {2023},
  doi = {10.3390/s23229196},
}