NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

MEMS-Based Reflective Intensity-Modulated Fiber-Optic Sensor for Pressure Measurements

Ning Zhou, Pinggang Jia, Jia Liu, Qianyu Ren, Guowen An, Ting Liang, Jijun Xiong2020

TL;DR

Researchers have developed a novel MEMS-based fiber-optic sensor for measuring pressure. This sensor utilizes a reflective intensity-modulation mechanism and a unique microsphere fiber tip to achieve high sensitivity and real-time, high-frequency pressure monitoring, making it suitable for harsh environments.

What Problem Does This Paper Address?

Accurate pressure measurement is crucial in many demanding fields, including oil logging and aerospace. While various pressure sensors exist, electrical sensors often struggle in harsh environments due to electromagnetic interference and material limitations. Fiber-optic sensors offer advantages like immunity to EMI, compact size, and robustness. However, existing fiber-optic pressure sensors, particularly those relying on intensity modulation, can have limitations in sensitivity, dynamic response, or manufacturing complexity. This paper aims to address these limitations by proposing a MEMS-fabricated, reflective intensity-modulated fiber-optic sensor with enhanced sensitivity and real-time high-frequency capabilities.

Methods

The core of this work lies in the design and fabrication of a MEMS-based sensor head. The sensor integrates two multimode optical fibers with spherical ends, a quartz tube, a silicon sensitive diaphragm, and a high borosilicate glass substrate (HBGS). The key innovation is the use of a microsphere at the fiber tip, which increases the numerical aperture (NA) of the fiber. This higher NA, as demonstrated through simulations, leads to a steeper slope in the light intensity modulation function, thereby improving pressure sensitivity.

Fabrication involves standard MEMS processes: lithography and dry etching to create a cavity in the silicon diaphragm, followed by gold film deposition for high reflectivity. The HBGS is then anodically bonded to the silicon diaphragm. For fiber integration, the microsphere-tipped multimode fibers are inserted into a quartz tube and then into the sensor head. The entire assembly is sealed using a CO2 laser, which is noted for its ability to improve performance and avoid thermal mismatch issues compared to adhesives.

The operating principle is based on reflective intensity modulation. Light from a source is transmitted through one fiber, reflects off the deformed silicon diaphragm, and is collected by the second fiber. The amount of reflected light, and thus the output signal, changes with pressure-induced diaphragm deformation.

Datasets

Not discussed in the paper. The experiments were conducted using a controlled laboratory setup with applied pressures and temperatures.

Key Insights and Ideas

  • Microsphere Fiber Tip for Enhanced Sensitivity: The spherical structure at the fiber end significantly increases the numerical aperture, leading to a more pronounced change in reflected light intensity for a given pressure, thus boosting sensitivity.
  • MEMS Fabrication for Miniaturization and Batch Production: The use of MEMS techniques allows for the creation of a compact sensor head and opens the door for cost-effective mass production.
  • CO2 Laser Sealing for Robustness: Employing a CO2 laser for sealing the sensor head helps to avoid thermal mismatch issues and improve overall sensor performance and reliability, especially in varying temperature environments.
  • Real-time High-Frequency Response: The intensity-modulation mechanism, combined with the sensor's design, allows for real-time monitoring of dynamic pressure changes at frequencies up to 1 kHz.

Key Results

  • The sensor achieved a pressure sensitivity of approximately 0.139 mV/kPa.
  • The temperature coefficient of the sensor was found to be around 0.87 mV/°C over the range of 20 °C to 150 °C.
  • The sensor demonstrated good linearity in its response to pressure across the tested range (0 to 1 MPa).
  • Repeatability and nonlinear errors were reported to be approximately 2.15% and less than 2.51%, respectively.
  • The sensor showed a good dynamic response in sinusoidal pressure environments at frequencies of 400 Hz, 780 Hz, and 1 kHz.

Limitations and Future Work

  • Temperature Limit: The sensor's welding part was observed to fail at temperatures exceeding 150 °C under 1 MPa pressure, indicating a limitation in its high-temperature operational range. The authors suggest that optimizing the welding process could extend this limit.
  • Further Optimization: While the sensor shows promising results, further work could focus on optimizing the MEMS fabrication process for even higher performance and exploring its application in more extreme environments.
  • Packaging and Integration: The paper focuses on the sensor head; future work could involve developing robust packaging solutions for diverse industrial applications.

Summary updated

BibTeX
@misc{zhou2020mems,
  author = {Ning Zhou and Pinggang Jia and Jia Liu and Qianyu Ren and Guowen An and Ting Liang and Jijun Xiong},
  title = {{MEMS-Based Reflective Intensity-Modulated Fiber-Optic Sensor for Pressure Measurements}},
  year = {2020},
  doi = {10.3390/s20082233},
}

Loading related content...

Figure