MemBrain: A Deep Learning-aided Pipeline for Automated Detection of Membrane Proteins in Cryo-electron Tomograms

Lorenz Lamm, Ricardo D. Righetto, Wojciech Wietrzyñski, Matthias Pöge, Antonio Martínez-Sánchez, Tingying Peng, Benjamin D. EngelbioRxiv 2022 · DOI

TL;DR

This paper introduces MemBrain, a novel deep learning pipeline for automatically detecting membrane proteins in cryo-electron tomograms (cryo-ET). MemBrain significantly outperforms existing methods by achieving high accuracy with minimal training data and can even estimate protein orientations, opening new avenues for structural biology research.

What Problem Does This Paper Address?

Cryo-electron tomography (cryo-ET) is a powerful technique for visualizing cellular structures at near-atomic resolution. However, the resulting 3D tomograms often suffer from low signal-to-noise ratios and anisotropic resolution, making it difficult to analyze them. A particularly challenging task is the automated detection of membrane-bound proteins, which are crucial for many cellular functions. Existing methods, including template matching and other deep learning approaches, struggle with the inherent noise, low resolution, and the vast number of proteins that need to be identified, often requiring extensive manual annotation and post-processing.

Methods

MemBrain tackles this challenge with a multi-stage pipeline:

  1. Membrane Segmentation: The process begins with pre-existing membrane segmentations from the tomograms.
  2. Subvolume Sampling and Preprocessing: Points are sampled on the segmented membrane. For each point, a 3D subvolume is extracted. Crucially, these subvolumes are then rotated so that the membrane is always aligned to the x-y plane. This "rotational subvolume normalization" is a key innovation, making the detection process invariant to the original orientation of the membrane in the tomogram.
  3. CNN Scoring: A convolutional neural network (CNN) is trained to assign a score to each subvolume, indicating its distance to the nearest protein center. The network uses a "tiny receptive field" and a regression-based approach (predicting distance rather than a binary classification), which is more robust to imprecise manual annotations.
  4. Post-processing: A refined Mean Shift clustering algorithm is used to extract the final protein center positions and, uniquely, their orientations.

Datasets

The authors evaluated MemBrain on three cryo-ET datasets:

  • Dataset 1: Isolated Spinacia oleracea (spinach) chloroplasts.
  • Dataset 2: Chlamydomonas reinhardtii chloroplasts within native cells.
  • Dataset 3: Isolated rod outer segments from wild-type mice.

For training and validation, they used 35 membranes from Dataset 1. The remaining tomograms from Dataset 1, along with Datasets 2 and 3, were used as test sets. The paper highlights that MemBrain can be trained effectively with a small number of annotated membranes (even just one), and a pre-trained model generalizes well to tomograms acquired with different cryo-ET methods and from different cell types.

Key Insights and Ideas

  • Rotational Normalization is Key: Aligning all subvolumes to a consistent membrane orientation (parallel to the x-y plane) is a critical step that greatly simplifies the detection task and allows the network to generalize across different membrane orientations.
  • Regression Over Classification for Label Efficiency: Using a CNN to predict the distance to a protein center, rather than simply classifying a subvolume as "protein" or "non-protein," makes the model more robust to the inherent inaccuracies in manual annotations, which are common in cryo-ET.
  • Orientation Estimation is a Game-Changer: Most existing methods only provide particle positions. MemBrain's ability to also estimate protein orientation is a significant advancement, providing richer information for downstream analyses like subtomogram averaging.
  • Label Efficiency is Practical: The ability to achieve high performance with very few training labels is crucial for cryo-ET, where data acquisition and manual annotation are time-consuming and labor-intensive.

Key Results

  • MemBrain achieves an F1 score of 0.92 on its test set, significantly outperforming other methods (max F1 score of 0.63).
  • It requires only a small amount of training data, achieving an F1 score of 0.88 with just a single annotated membrane.
  • The pipeline can estimate protein orientations with a mean absolute error of 24.4 degrees on Dataset 1.
  • A pre-trained MemBrain model demonstrates good generalization to tomograms acquired using different cryo-ET techniques and from different cell types.
  • The recall for MemBrain far exceeds other methods, meaning it misses fewer ground-truth particles.

Limitations and Future Work

  • Manual Membrane Segmentation: The pipeline relies on pre-existing membrane segmentations, which still require manual curation. While the paper mentions tools for this, it's a prerequisite.
  • Protein Size Dependency: While the chosen subvolume size (12x12x12) is robust, it might need adjustment for detecting extremely small or large proteins.
  • Generalization to Diverse Proteins: While MemBrain generalizes well across datasets and cryo-ET methods, its performance on proteins with very different shapes or densities than those used for training might require further fine-tuning.
  • Future Work: The authors suggest that the extracted particle positions and orientations can be used to analyze the organization of protein complexes within membranes, revealing how they interact to drive cellular processes. The generalizability of MemBrain suggests its applicability to a wide range of biological membranes.

Summary updated

Abstract

Abstract Background and Objective Cryo-electron tomography (cryo-ET) is an imaging technique that enables 3D visualization of the native cellular environment at sub-nanometer resolution, providing unpreceded insights into the molecular organization of cells. However, cryo-electron tomograms suffer from low signal-to-noise ratios and anisotropic resolution, which makes subsequent image analysis challenging. In particular, the automated detection of membrane-embedded proteins is a problem still lacking satisfactory solutions. Methods We present MemBrain – a new deep learning-based pipeline that automatically detects membrane-bound protein complexes in cryo-electron tomograms. After subvolumes are sampled along a segmented membrane, each subvolume is assigned a score using a convolutional neural network (CNN), and protein positions are extracted by a clustering algorithm. Incorporating rotational subvolume normalization and using a tiny receptive field simplify the task of protein detection and thus facilitate the network training. Results MemBrain requires only a small quantity of training labels and achieves excellent performance with only a single annotated membrane (F1 score: 0.88). A detailed evaluation shows that our fully trained pipeline outperforms existing classical computer vision-based and CNN-based approaches by a large margin (F1 score: 0.92 vs. max. 0.63). Furthermore, in addition to protein center positions, MemBrain can determine protein orientations, which has not been implemented by any existing CNN-based method to date. We also show that a pre-trained MemBrain program generalizes to tomograms acquired using different cryo-ET methods and depicting different types of cells. Conclusions MemBrain is a powerful and label-efficient tool for the detection of membrane protein complexes in cryo-ET data, with the potential to be used in a wide range of biological studies. It is generalizable to various kinds of tomograms, making it possible to use pretrained models for different tasks. Its efficiency in terms of required annotations also allows rapid training and fine-tuning of models. The corresponding code, pretrained models, and instructions for operating the MemBrain program can be found at: https://github.com/CellArchLab/MemBrain
BibTeX
@misc{lamm2022membrain,
  author = {Lorenz Lamm and Ricardo D. Righetto and Wojciech Wietrzyñski and Matthias Pöge and Antonio Martínez-Sánchez and Tingying Peng and Benjamin D. Engel},
  title = {{MemBrain: A Deep Learning-aided Pipeline for Automated Detection of Membrane Proteins in Cryo-electron Tomograms}},
  year = {2022},
  doi = {10.1101/2022.03.01.480844},
  howpublished = {bioRxiv},
}
Figure