MedRECT: A Medical Reasoning Benchmark for Error Correction in Clinical Texts

Naoto Iwase, Hiroki Okuyama, Junichiro IwasawaarXiv 2025 · DOI · arXiv

TL;DR

This paper introduces MEDRECT, the first cross-lingual benchmark for medical error detection and correction, designed to evaluate Large Language Models (LLMs) in both Japanese and English. By developing a novel, scalable methodology for benchmark creation and conducting extensive evaluations, the authors highlight the critical role of reasoning capabilities in LLMs for medical applications and demonstrate a path towards safer, more transparent medical AI.

What Problem Does This Paper Address?

The increasing integration of LLMs into healthcare promises to augment clinical decision-making. However, a critical concern remains: the reliability and transparency of their reasoning processes. While LLMs excel at tasks like multiple-choice question answering (MCQA) on medical exams, their ability to detect and correct errors in unstructured clinical text – a crucial step for safe deployment – is less understood, especially across different languages. Existing benchmarks are often resource-intensive to create, monolingual, and may not fully capture the nuanced reasoning required in real-world clinical practice. This gap hinders the development of robust and trustworthy medical AI systems, particularly in non-English speaking regions.

Methods

The authors introduce MEDRECT, a benchmark that frames medical error handling as three subtasks:

  1. Error Detection: Identifying if a clinical text contains an error.
  2. Error Sentence Extraction: Pinpointing the specific sentence with the error.
  3. Error Correction: Generating a corrected version of the erroneous sentence.

A key innovation is their scalable, automated pipeline for benchmark creation. For MEDRECT-ja, they synthesized data from Japanese Medical Licensing Examinations (JMLE) by using LLMs to transform MCQA questions into clinical texts, creating both correct and erroneous samples. For MEDRECT-en, they leveraged the existing MEDEC benchmark. Rigorous quality control steps, including LLM-as-a-Judge screening and filtering based on validation model performance, were employed to ensure high-quality, appropriately challenging datasets.

They also explored LoRA (Low-Rank Adaptation) fine-tuning on a bilingual dataset (Japanese and English) using reasoning synthesis data generated by DeepSeek-R1-0528. This approach aimed to enhance error correction capabilities while preserving the models' reasoning abilities.

Datasets

  • MEDRECT-ja: A newly constructed benchmark comprising 663 clinical texts, derived from JMLE questions.
  • MEDRECT-en: A benchmark comprising 458 clinical texts, derived from the MEDEC MS Subset Test.
  • JMLE (Japanese Medical Licensing Examinations): Used as the source for MEDRECT-ja.
  • MEDEC: A benchmark for medical error detection and correction in English, used as the source for MEDRECT-en.

Key Insights and Ideas

  • Reasoning is Paramount: LLMs with explicit reasoning capabilities significantly outperform non-reasoning models across all subtasks (detection, extraction, and correction). This highlights that understanding how a model arrives at an answer is crucial for medical applications.
  • Cross-Lingual Gaps Exist, But Are Bridgeable: While there's a performance gap between English and Japanese for most models, reasoning models show smaller disparities. Targeted fine-tuning can effectively transfer knowledge and improve performance across languages.
  • Fine-Tuning for Empathy and Restraint: The fine-tuned model not only improved metric scores but also demonstrated better empathetic communication and a crucial ability to avoid overcorrecting accurate texts, addressing key concerns for practical deployment.
  • Sentence Extraction is a Bottleneck: Identifying the exact erroneous sentence is a significant challenge, indicating that precise localization requires more sophisticated understanding than simple error detection.

Key Results

  • Top Performers: Claude Sonnet 4 achieved the highest overall performance on MEDRECT-ja (0.675 average score), with strong capabilities in error detection and correction.
  • Reasoning vs. Non-Reasoning: Reasoning models consistently showed higher performance. For example, the "think" mode of Qwen3-32B significantly outperformed its "no-think" counterpart, showing a 13.5% relative improvement in error detection and a 51.0% improvement in sentence extraction.
  • Cross-Lingual Performance: Most proprietary models performed better on English. However, the fine-tuned Qwen3-32B + LoRA model showed substantial improvements on both languages, with particularly strong English performance (0.718 average score) despite being trained primarily on Japanese data.
  • Error Type Difficulty: Medication dosage was the most challenging error type for sentence extraction, while medication selection was the most tractable.
  • Human-Level Performance: The fine-tuned model surpassed human expert performance on sentence extraction and error correction metrics on the original MEDEC benchmark.

Limitations and Future Work

  • Dataset Size: The MEDRECT-ja dataset is limited by the availability of suitable JMLE questions that can be transformed into clinical case scenarios.
  • Synthetic Errors: The automated error generation might not fully capture the diversity of errors found in real clinical practice.
  • Model Bias: The benchmark construction relied on specific LLMs for synthesis and quality screening, potentially introducing model-specific biases.
  • Multimodality: The current benchmark focuses solely on text and does not account for multimodal clinical documents (images, tables).

Future work could involve expanding the dataset size, exploring more sophisticated error generation techniques, and developing benchmarks that incorporate multimodal information. The authors envision MEDRECT as a crucial resource for advancing safer, more equitable medical AI systems globally.

Summary updated

BibTeX
@misc{iwase2025medrect,
  author = {Naoto Iwase and Hiroki Okuyama and Junichiro Iwasawa},
  title = {{MedRECT: A Medical Reasoning Benchmark for Error Correction in Clinical Texts}},
  year = {2025},
  eprint = {2511.00421},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2511.00421},
}
Figure