NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Mechanosensitive ion channel gene survey suggests potential roles in primary open angle glaucoma

Wendy W. Liu, Tyler G. Kinzy, Jessica N. Cooke Bailey, Zihe Xu, Pirro G. Hysi, Janey L. Wiggs, R. Rand Allingham, Murray H. Brilliant, Donald L. Budenz, John H. Fingert, Douglas Gaasterland, Teresa Gaasterland, Jonathan L. Haines, Michael A. Hauser, Richard K. Lee, Paul R. Lichter, Yutao Liu, Sayoko E. Moroi, Jonathan S. Myers, Louis R. Pasquale, Margaret A. Pericak‐Vance, Anthony Realini, Doug Rhee, Julia E. Richards, Robert Ritch, Joel S. Schuman, William K. Scott, Kuldev Singh, Arthur J. Sit, Douglas Vollrath, Robert N. Weinreb, Gadi Wollstein, Donald J. ZackScientific 2023

TL;DR

This study identifies specific genetic variants in mechanosensitive ion channel genes, particularly in PIEZO1, that are associated with a reduced risk of primary open-angle glaucoma (POAG). These findings suggest that these channels, which sense mechanical forces, could be novel therapeutic targets for treating this blinding eye disease.

What Problem Does This Paper Address?

Primary open-angle glaucoma (POAG) is a leading cause of irreversible blindness, and while elevated intraocular pressure (IOP) is a known risk factor, the precise mechanisms by which pressure is sensed and how it leads to retinal ganglion cell (RGC) damage remain poorly understood. Mechanosensitive ion channels are prime candidates for mediating these pressure-sensing roles, as they are involved in various physiological processes that respond to mechanical stimuli. However, direct clinical evidence linking these channels to POAG in humans has been lacking. This paper aims to bridge this gap by systematically investigating whether genetic variations in key mechanosensitive ion channel genes are associated with POAG risk.

Methods

The researchers employed a two-pronged genetic association approach:

  1. Common Variant Analysis: They surveyed common single nucleotide polymorphisms (SNPs) with a minor allele frequency (MAF) greater than 5% within the genomic regions of 20 mechanosensitive ion channel genes (belonging to K2P, TMEM63, PIEZO, and TRP families). This analysis utilized genotype data from the large NEIGHBORHOOD consortium (3853 cases, 33,480 controls).
  2. Rare Variant Analysis: They investigated rare coding variants (MAF < 1%) using exome array genotyping data from a subset of the NEIGHBORHOOD cohorts (2606 cases, 2606 controls).

Association with POAG was assessed using logistic regression, adjusting for age and sex. For validation and replication, data from the UK Biobank and FinnGen datasets were also utilized. Additionally, the study examined the expression patterns of these genes in ocular tissues using publicly available single-cell and single-nucleus RNA sequencing data.

Datasets

  • NEIGHBORHOOD Consortium: A large dataset comprising 3853 POAG cases and 33,480 controls, used for both common and rare variant association analyses. This consortium includes eight independent datasets.
  • UK Biobank: Used for replication of findings, particularly for rare coding variants.
  • FinnGen: A Finnish population dataset used for replication of findings.
  • Gene-Tissue Expression (GTEx) database: Used to identify SNPs that are expression quantitative trait loci (eQTLs).
  • Publicly available single-cell and single-nucleus RNA sequencing data: Used to assess gene expression in ocular tissues.

Key Insights and Ideas

  • PIEZO1 Variants as Protective Factors: The most striking finding is the identification of two rare PIEZO1 coding variants that appear to confer protection against POAG. This suggests that modulating PIEZO1 function could be a therapeutic strategy.
  • Mechanosensitive Channels as Direct POAG Contributors: The study provides strong genetic evidence linking specific mechanosensitive ion channel genes to POAG risk, moving beyond experimental or in vitro observations.
  • Divergent Roles of Common vs. Rare Variants: While rare variants in PIEZO1 showed a clear protective effect, common variants in PIEZO1 and PIEZO2 also showed associations, suggesting complex genetic contributions from both rare and common variations.
  • Tissue-Specific Expression Patterns: The expression data reveals that key mechanosensitive genes are present in ocular tissues relevant to POAG pathogenesis, such as lymphatic endothelial cells (involved in aqueous humor outflow) and retinal ganglion cells.

Key Results

  • Rare PIEZO1 Variants:
    • A missense variant, R1527H, showed a significant protective effect (OR 0.17, P = 0.0018).
  • A variant affecting a canonical splice donor site (g.16-88737727-C-G Hg38) also demonstrated a protective effect (OR 0.38, P = 0.02).
  • Both these PIEZO1 variants showed consistent protective effects in the UK Biobank, and R1527H was also replicated in FinnGen.
  • Common Variants: Several common SNPs in PIEZO1, PIEZO2, TRPV2, TRPM3, and KCNK2 (TREK1) reached study-specific thresholds for association with POAG, high-tension glaucoma (HTG), or normal-tension glaucoma (NTG) in the NEIGHBORHOOD dataset.
  • Gene Expression: PIEZO1 and PIEZO2 are highly expressed in lymphatic endothelial cells of the anterior segment, and TMEM63B, TMEM63C, TRPM3, and TRPV2 are expressed in retinal ganglion cells.

Limitations and Future Work

  • Functional Elucidation: The study identifies genetic associations but does not definitively determine whether the identified PIEZO1 variants confer gain or loss of function. Future functional studies are needed to understand the precise impact of these variants on channel activity and POAG pathogenesis.
  • Replication of Common Variants: While some common variants showed associations in NEIGHBORHOOD, they did not consistently replicate in the FinnGen dataset, suggesting potential population-specific effects or limitations in replication sample sizes.
  • Exome Array Limitations: The rare variant analysis was limited to variants present on the exome array, which is not a comprehensive representation of all rare coding variants. Whole-exome or whole-genome sequencing would provide a more complete picture.
  • Glaucoma Classification: The use of diagnosis codes and self-reports for glaucoma classification in the UK Biobank and FinnGen datasets can introduce variability.
  • Ethnicity: The study primarily focused on individuals of European ancestry. Including ethnically diverse populations in future studies is recommended.

The authors suggest that future functional studies are warranted to elucidate the effects of these variants on channel function and glaucoma phenotypes. Including ethnically diverse populations and employing whole-exome or whole-genome sequencing for a more comprehensive rare variant analysis are also recommended future directions.

Summary updated

BibTeX
@inproceedings{liu2023mechanosensitive,
  author = {Wendy W. Liu and Tyler G. Kinzy and Jessica N. Cooke Bailey and Zihe Xu and Pirro G. Hysi and Janey L. Wiggs and R. Rand Allingham and Murray H. Brilliant and Donald L. Budenz and John H. Fingert and Douglas Gaasterland and Teresa Gaasterland and Jonathan L. Haines and Michael A. Hauser and Richard K. Lee and Paul R. Lichter and Yutao Liu and Sayoko E. Moroi and Jonathan S. Myers and Louis R. Pasquale and Margaret A. Pericak‐Vance and Anthony Realini and Doug Rhee and Julia E. Richards and Robert Ritch and Joel S. Schuman and William K. Scott and Kuldev Singh and Arthur J. Sit and Douglas Vollrath and Robert N. Weinreb and Gadi Wollstein and Donald J. Zack},
  title = {{Mechanosensitive ion channel gene survey suggests potential roles in primary open angle glaucoma}},
  booktitle = {Scientific},
  year = {2023},
  doi = {10.1038/s41598-023-43072-3},
}
Figure